1.5 hp Chiller – Cooler Chiller
The condenser plays a very important role in the 1.5 hp chiller system. Its work directly affects the overall efficiency of the entire equipment. If you want to improve the efficiency of the condenser, you must remember the following 5 points.
1. Condenser capacity: The capacity in the condenser is not determined according to the power of the fan, but calculated from the surface of the condenser, and calculating the capacity according to the surface can improve its efficiency.
2. Fan configuration: It is recommended that you use an axial fan for the fan, which can not only improve the efficiency of the condenser, but also improve the cooling efficiency of the 1.5 hp chiller.
3. Motor: Equipped with a high-efficiency motor can greatly improve the energy saving of a 1.5 hp chiller.
4. Condenser pipe cleaning: Dirt and clogging cannot be avoided after the condenser has been used for a long time, so the condenser needs to strengthen its daily maintenance work, which will help the condenser to improve its efficiency.
5. Check the oil and refrigerant: When the condenser is in operation, it is inevitable that the refrigeration oil will deteriorate or stick to the pipeline, resulting in a decrease in refrigeration efficiency. The reduction of refrigerant will also lead to a decrease in refrigeration efficiency, and it is necessary to add refrigerant in time.
Customized Solutions For Your Business
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -150°C to -5°C
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW |
Recirculating Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers
Temperature Control Range: +5°C to +50°C
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments
Temperature Control Range: -120°C to -10°C
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Direct Cooling Ultra Low Temp Chillers
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperature range | -150°C ~ -110°C |
Cooling Capacity | up to 11kW |
Screw Chillers
Low temperature screw chillers and room temperature screw chillers
Customized solutions for your business.
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |