Search Search all

20 Ton Chiller – Chiller Manufacturer

ClassificationIndustry News 308

20 Ton Chiller – Chiller Manufacturer

 

20 ton chiller is a very important refrigeration equipment for an enterprise. Its operation stability has a non-negligible effect on production efficiency and product quality. Therefore, regular maintenance of the chiller is required to ensure the normal operation of the chiller. of.

So, how to maintain the 20 ton chiller?

1. Replace lubricating oil

After the 20 ton chiller group is used for a long time, the oil quality of the lubricating oil will deteriorate, and the impurities and moisture inside the oil will increase, so it is necessary to observe and check the oil quality regularly, and replace it in time if any problem is found.

In addition, I would like to remind everyone that the grade of lubricating oil to be replaced must comply with the technical data to avoid additional damage to the chiller due to incorrect use of lubricating oil.

2. Replace the dry filter

The dry filter is an important part to ensure the normal circulation of the refrigerant. Since water and refrigerant are incompatible with each other, if there is water in the system, it will greatly affect the operating efficiency of the unit.

Therefore, the filter element inside the drying filter must be replaced regularly to keep the inside of the system dry for a long time.

3. Calibration of the safety valve

Both the condenser and evaporator of the 20 ton chiller are pressure vessels. According to regulations, a safety valve should be installed on the high-pressure end of the unit, that is, the condenser body. Once the unit is in an abnormal working environment, the safety valve can automatically release the pressure. Prevent possible damage to the human body caused by high voltage. Therefore, in order to ensure the safety of the staff, the safety valve must be checked regularly.

4. Cleaning of condenser and evaporator

The cooling water of the water-cooled condenser is an open circulation loop, and tap water is generally used to circulate through the cooling tower. However, when the content of calcium salt and magnesium salt in the water is large, it is easy to decompose and deposit on the cooling water pipe to form scale, which affects heat transfer. Excessive scaling will also reduce the circulation section of cooling water, reduce the amount of water, and increase the condensation pressure.

Therefore, when the water quality of the cooling water used is poor, the cooling water pipe should be cleaned at least once a year to remove scale and other dirt in the pipe.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

 

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller