2hp Water Chiller – Cooling Chiller
After any piece of mechanical equipment has been in operation for a long time, there will be a series of problems, and corrosion of industrial chiller equipment is also one of the common ones. In order to avoid corrosion and other phenomena in the 2hp water chiller, we will tell you the reasons for the corrosion of the chiller below, and then you can take effective corresponding measures to avoid problems and even affect the normal production of the factory.
1. Unreasonable selection of installation location
After many companies purchase 2hp water chillers, they have not done anti-corrosion, anti-rust and other processes, so they are directly placed in the indoor environment, and repeatedly exposed to wind and sun, which will cause problems such as shell corrosion after a long time.
2. The water processor is installed incorrectly
Whether the water quality is good or bad determines whether there will be scale and rust in the pipeline. At this time, the water processor plays a very important role. If the water processor is not installed properly, it will cause rust or corrosion.
3. Regularly replace the filter
The filter plays the role of filtering impurities, but after the 2hp water chiller has been running for a long time, it is easy to cause other impurities such as condenser fouling/mud accumulation, so we need to replace the filter regularly to ensure that the inside is clean.
4. There is no blowdown valve installed
The blowdown valve plays a very good blowdown effect on the 2hp water chiller, and it also has corrosion resistance and impact resistance. The main sewage valve has a simple structure and good sealing performance.
5. The water supply pipeline should be equipped with a water meter
The water quality treatment method in the 2hp water chiller generally uses medicaments or bacterial agents. These two methods can kill internal fungi, microorganisms, and various types of dirt, etc., and must be used in accordance with the amount of water replenishment and the amount of water in the system. medicine. If the water supply pipeline is not equipped with a water meter, it will cause inaccurate dispensing, which will lead to corrosion of the pipeline in the later stage and cause greater losses.
6. Air environment and other issues
It is inevitable that there will be special gas flow in factory production, and these special gases will cause harm to the surface of the equipment. If you install a 2hp water chiller in such an environment, you must explain it clearly to the professionals in advance, and you must choose explosion-proof and resistant Corroded pipelines to avoid various problems in the later stage.
For 2hp water chiller, we should maintain regularly, regularly maintain, reduce failure rate, increase service life.
Customized Solutions For Your Business
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -150°C to -5°C
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW |
Recirculating Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers
Temperature Control Range: +5°C to +50°C
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments
Temperature Control Range: -120°C to -10°C
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Direct Cooling Ultra Low Temp Chillers
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperature range | -150°C ~ -110°C |
Cooling Capacity | up to 11kW |
Screw Chillers
Low temperature screw chillers and room temperature screw chillers
Customized solutions for your business.
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |