Search Search all

-45 to 250℃ High and Low Temperature Circulator

ClassificationIndustry News 4 0

-45 to 250℃ High and Low Temperature Circulator

 

-45 to 250℃ High and Low Temperature Circulator is a high-performance temperature control device suitable for applications that require precise temperature control within an extreme temperature range. This equipment is commonly used in laboratories, industrial production and R&D, especially in chemical synthesis, pharmaceuticals, materials science and biotechnology.

Main features of -45 to 250℃ High and Low Temperature Circulator

1. Wide temperature range:

• The operating temperature range is from -45°C to +250°C, which can meet the experimental needs under various extreme temperature conditions.

2. High-precision temperature control:

• The temperature control accuracy can reach ±0.1°C or higher.

• PID control algorithm is used to ensure temperature stability and accuracy.

3. Multiple heat transfer media support:

• A variety of heat transfer media such as water, ethylene glycol solution, silicone oil, etc. can be used to adapt to different temperature ranges and application requirements.

4. Intelligent control system:

• Built-in microprocessor control, supporting programming and data recording.

• Touch screen operation interface, easy to set and monitor temperature curves.

• Support remote monitoring and data transmission, convenient for management and recording of experimental data.

5. Efficient refrigeration and heating system:

• Adopt efficient compressor refrigeration system to quickly reduce the temperature.

• Electric heating elements provide fast heating capability to meet high temperature operation requirements.

6. Safety protection function:

• Overtemperature protection: Automatically stop heating when the temperature exceeds the set value.

• Low liquid level alarm: Alarm when the heat transfer medium level is too low.

• Pressure protection: Prevent system pressure from being too high to ensure safe operation.

7. Compact design:

• Compact design, small footprint, suitable for laboratory benchtops.

• Easy to move and install, convenient for flexible use on different laboratory benches.

8. Easy to maintain:

• Easy to disassemble and clean, convenient for daily maintenance.

• Some models are equipped with self-cleaning function to reduce maintenance workload.

 

-45 to 250℃ High and Low Temperature Circulator

Application areas of -45 to 250℃ high and low temperature circulators

• Chemical synthesis: organic synthesis, catalytic reaction, etc.

• Pharmaceutical research and development: drug synthesis, extraction, purification, etc.

• Material science: research and development and testing of new materials.

• Biotechnology: enzyme activity research, protein crystallization, etc.

• Food processing: food composition analysis, microbial culture, etc.

Key points for selecting a high and low temperature circulator from -45 to 250°C

1. Temperature range:

• Make sure that the operating temperature range of the selected equipment covers your specific needs (-45°C to +250°C).

2. Temperature control accuracy:

• Select the appropriate accuracy level (such as ±0.1°C) according to the experimental requirements for temperature control.

3. Capacity and flow:

• Select the appropriate equipment capacity and fluid flow according to actual needs to ensure that the heat load requirements of the reactor or other equipment are met.

4. Medium compatibility:

• Select a system suitable for the heat transfer medium you are using to ensure long-term stable operation.

5. Control system:

• Select equipment with an intelligent control system that is easy to set up and monitor, and supports programming and data logging functions.

6. Safety:

• Ensure that the equipment has the necessary safety protection measures to prevent accidents.

7. Maintenance and Care:

• Choose equipment that is easy to maintain and care for lower long-term operating costs.

If you have a specific budget range, application scenario, or special requirements, please provide more details and I will provide you with more specific suggestions and recommendations. This will help you better choose a -45 to 250℃ high and low temperature circulator that suits your laboratory needs.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller