Search Search all

5 Ton Water Chiller – Industrial Chiller Supplier

ClassificationIndustry News 244

5 Ton Water Chiller – Industrial Chiller Supplier

 

The relevant parts of the 5 ton water chiller will cause certain problems during use. Therefore, reasonable and scientific maintenance and repair can effectively avoid the occurrence of failures.

First, inspection and maintenance of 5 ton water chiller

The compressor of the chiller will make noise when it is working. This may be a problem with the expansion valve. Pay more attention to the expansion valve at ordinary times. In addition, the pipeline and condenser should be cleaned regularly to ensure smooth circulation. If the suction pressure of your 5 ton water chiller is too high, pay attention to the amount of refrigerant used, excess or reduction will cause the suction pressure to rise, and improper adjustment of the expansion valve will also cause changes in the suction of the chiller.

Second, the maintenance method of the condenser

1. Detection

Condenser is a key part in 5 ton water chiller, therefore, in the production process, various failures often occur. Pay close attention to the pressure of the condenser, do not add too much refrigerant, and do not have air and non-condensable gases, otherwise the pressure of the condenser will increase, which will affect the normal operation of the condenser.

2. Environment

As long as the condenser of the 5 ton water chiller is in normal working condition, its working efficiency will reach a very high level. Since the main function of the condenser is cooling, it will definitely cause different degrees of pollution to the nearby environment in the case of a bad working environment. Only a good heat dissipation effect can ensure the normal operation of the condenser of the industrial chiller.

Therefore, in daily maintenance, it is necessary to ensure that the temperature of the condenser is volatilized in the shortest time, so as to ensure the cooling capacity of the equipment and ensure the safety of the operation of the equipment.

3. Clean

When using the 5 ton water chiller, all parts must be cleaned carefully to ensure its normal operation. Especially the fins, because there are gaps between the fins, a large amount of dust will seep into the fins, resulting in poor heat dissipation and seriously affecting the work of the condenser. It is necessary to ensure that the condenser is checked regularly after the 6-month cycle of the industrial chiller.

If it is used for a long time, thick dirt will form on the heat transfer surface of the condenser, and it will adhere to the surface of the radiator. As time goes by, it will affect the heat dissipation effect of the condenser, and regular descaling and maintenance must be carried out.

 

Customized Solutions For Your Business


low temperature chiller

 

Low Temperature Chillers (Water Cooled or Air Cooled)

Ultra-low temperature cascade refrigeration technology.

Each temperature segment has more than a dozen product models for you to choose from.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity3 ~ 103 Ton1.5 ~ 103 Ton1.5 ~ 103 Ton1.1 ~ 77 Ton0.5 ~ 52 Ton0.7 ~ 3.2 Ton

 


recirculating chiller

 

Recirculating Chillers (Water Cooled or Air Cooled)

Closed circulation pipeline, ethylene glycol mixed with water for refrigeration.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.2 ~ 11 Ton0.1 ~ 3.5 Ton0.1 ~ 2.1 Ton0.05 ~ 2.1 Ton0.08 ~ 2.5 Ton

 


water chiller

 

Room Temperature Chillers / Small Chillers

High-precision refrigeration temperature control system.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.09 ~ 0.26 Ton0.5 ~ 15 Ton

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

It is suitable for places with small heat exchange area and large heat exchange.

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

The ultra-low temperature direct cooling chiller adopts the secondary subcooling technology, and the cooling speed is fast. The refrigerant in the refrigeration system is directly output and evaporated into the target control element (heat exchanger) for cooling.

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller