70 Ton Chiller – Water Chiller Manufacturer
How to maintain the 70 ton chiller daily?
1. Routine inspection
Every other week, it is necessary to check whether the water level of the 70 ton chiller meets the requirements, and check whether the water quality of the chiller has changed (color, smell, impurities, etc.) once a month. Followed by regular replacement and cleaning, you can refer to the following replacement and cleaning cycle.
2. Filter cleaning cycle
According to the water quality, check once a week whether the filter is clogged (laser water inlet filter, water cooler filter), the laser water inlet filter is in the Y-shaped laser water inlet, and the 70 ton chiller filter can be confirmed according to the equipment model The location is generally on the outlet pipe.
3. Dust filter cleaning cycle and cleaning steps
The dust filter is on both sides of the 70 ton chiller, and the dust filter is easy to remove. When there is a lot of dust, the frequency of cleaning can be increased. Remove the dust screen and use an air spray gun to remove the dust on the dust screen. For oily dirt, please clean it with a neutral detergent. Before reinstalling the dust screen, rinse and dry it.
4. Filter replacement cycle
Check whether the filter element of the 70 ton chiller is polluted, and the filter element needs to be replaced every six months at most (depending on the actual model, some have no filter element).
5. Cooling water replacement cycle
Replace the cooling water according to the water quality, and the cooling water needs to be replaced once every 3 months at the longest. The water tank of the 70 ton chiller is not sealed. It is exposed to dust for a long time. Dust, metal shavings and bacteria enter the cold water and cause the water to deteriorate. Substances that do not dissolve water are produced and adhere to the inner wall of the laser waterway, thereby blocking the waterway and causing water leakage. The flow rate drops, reducing the cooling effect. If this happens, drain all the deteriorated cooling water in time and replace it with new cooling water.
Customized Solutions For Your Business
Low Temperature Chillers (Water Cooled or Air Cooled)
Ultra-low temperature cascade refrigeration technology.
Each temperature segment has more than a dozen product models for you to choose from.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series |
Cooling Capacity | 3 ~ 103 Ton | 1.5 ~ 103 Ton | 1.5 ~ 103 Ton | 1.1 ~ 77 Ton | 0.5 ~ 52 Ton | 0.7 ~ 3.2 Ton |
Recirculating Chillers (Water Cooled or Air Cooled)
Closed circulation pipeline, ethylene glycol mixed with water for refrigeration.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | 0.2 ~ 11 Ton | 0.1 ~ 3.5 Ton | 0.1 ~ 2.1 Ton | 0.05 ~ 2.1 Ton | 0.08 ~ 2.5 Ton |
Room Temperature Chillers / Small Chillers
High-precision refrigeration temperature control system.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | 0.09 ~ 0.26 Ton | 0.5 ~ 15 Ton |
Direct Cooling Type Refrigeration Equipments
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Direct Cooling Ultra Low Temp Chillers
The ultra-low temperature direct cooling chiller adopts the secondary subcooling technology, and the cooling speed is fast. The refrigerant in the refrigeration system is directly output and evaporated into the target control element (heat exchanger) for cooling.
Temperature range | -150°C ~ -110°C |
Cooling Capacity | up to 11kW |