Search Search all

Process Cooling Water System

ClassificationIndustry News 219 0

Process Cooling Water System

Contact us today for the perfect temperature control solution

 

Process cooling water system is one of the circulation systems used in the fields of industrial production, energy and construction. It is usually used to transfer heat from high-temperature or high-energy equipment to cooling water and dissipate heat to the air or underground.

The process cooling water system consists of multiple components, including water circulation pumps, cooling towers, cooling water pipes and coolers. The water circulation pump draws the cooling water from the cooling tower, circulates it in the equipment and returns it to the cooling tower for heat dissipation. Cooling towers spray hot water into the air flow from the cooling area, causing the water to be cooled and returned to the system. Cooling water pipes carry cooling water to different equipment and return hot water to the cooling tower. A cooler is a device that transfers hot water to cooling water.

 

Process Cooling Water System

 

Comparison of open and closed process cooling water systems

The process cooling water system is divided into two types: open system and closed system. The closed system mainly consists of water pump, plate exchanger, process equipment, pipe network and constant pressure equipment. The open system mainly consists of water tank, water pump, plate exchanger, process equipment. Equipment and pipe network.

The same points between open and closed systems:

①All are indirect heat transfer;

② Process equipment has relatively high requirements for water quality, so softened water is required for system water replenishment (secondary reverse osmosis water from a pure water station can be used as system water replenishment, without adding a water treatment device);

③The system refrigerant is all refrigerator cooling water.

The differences between open systems and closed systems:

① The cooling water in the open system is partially in contact with the atmosphere at the water tank;

② The open system cannot utilize the system return water pressure and is not energy-saving enough.

 

Process Cooling Water System

 

Selection of process cooling water system mode

The mode of process cooling water system is divided into open system and closed system. How to choose open system and closed system during the design process should be based on the following situations:

① When the height difference between the highest point of the process equipment and the water pump plate replacement equipment is relatively large (height difference exceeds 10m), it is recommended to use a closed system, so that the residual pressure and static head of the equipment can be fully utilized;

② When the water supply pressure of process equipment is very high but the pressure difference of the equipment is not large, it is recommended to use a closed system, so that the residual pressure of the pipe network can be used to reduce the water pump head and save energy;

③ When the plant process equipment is put into production in phases or in batches or when the equipment update and adjustment are relatively simple, taking into account the system debugging ability, it is recommended to use an open system, which can speed up the system debugging and operation. At the same time, due to the addition of a water tank, the system retains more water and the cold source When interrupted, it has certain accident buffering capabilities.

④ From the perspective of energy saving, the use of a closed system can greatly reduce the head of the process cooling water supply circulation pump. On the one hand, it can save the initial investment, on the other hand, it can save energy and reduce operating costs.

⑤ When the cooling water temperature of the equipment can be directly cooled by a cooling tower on the hottest days or the owner requires a small investment, an open system can be used. When the equipment cooling water inlet temperature cannot be met by an open cooling tower, a closed system is used, using chilled water as the refrigerant.

 

Process Cooling Water System

 

In conclusion

Process cooling water system is widely used in semiconductor, microelectronics and other industries. In order to achieve good benefits in improving the stability of system engineering, reducing engineering costs and saving energy, during the system engineering design process, users need to choose based on actual usage conditions. ideal operating mode.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products up to 900 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 


 

Cooling Chillers                                                                                                     

 

recirculating chiller

Recirculating Chillers / Refrigerated Circulator

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Precision Chillers / Small ChillersWater Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6 ~ 40kW2 ~ 15kW1 ~ 8kW0.6 ~ 3kW1.5 ~ 3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

Cooling and Heating Chillers                                                                            

 

Cooling and Heating Chillers

(Custom Designs)

Temperature Control Range: -120°C to +350°C

cooling and heating thermostat, widely used in various industry.

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Recirculating Heater Chillers

(Custom Designs)

Temperature Control Range: -45°C to +250°C

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller