The chiller refrigeration cycle is a device used for industrial cooling. It generally consists of a compressor, condenser, evaporator and water pump. The cooled water is sucked in from the water pump, cooled by the circulating water through the condenser, and then evaporated through the evaporator to reduce the cooling water temperature to the required temperature.

The chiller refrigeration cycle is widely used in the field of industrial refrigeration. Especially in plastic processing, food processing, rubber processing, petrochemicals, cosmetics processing and other industries, the application of chiller refrigeration cycle is becoming more and more widespread. It can not only help companies save energy, but also maintain the health and safety of the production environment while maintaining product production quality.

 

Chiller Refrigeration Cycle

 

The chiller refrigeration cycle consists of three interrelated systems: refrigerant circulation system, water circulation system, and electrical automatic control system.

Refrigerant circulation system:

The liquid refrigerant in the evaporator absorbs heat from the water and begins to evaporate. The liquid refrigerant also completely evaporates and becomes gaseous, and is sucked and compressed by the compressor. The gaseous refrigerant absorbs heat through the condenser, condenses into liquid, and passes through the thermal expansion valve ( or capillary tube) after throttling, it becomes low-temperature and low-pressure refrigerant and enters the evaporator to complete the refrigerant cycle process.

Water circulatory system:

The water circulation system uses a water pump to pump water from the water tank to the equipment that the user needs to cool. The chilled water takes away the heat and the temperature rises, and then returns to the chilled water tank.

Electrical automatic control system:

The electrical automatic control system includes the power supply part and the automatic control part.

The power supply part supplies power to compressors, fans, water pumps, etc. through contactors.

The automatic control part includes thermostat, pressure protection, delayer, relay, overload protection, etc., which are combined to achieve automatic start and stop, protection and other functions according to the water temperature.

 

Chiller Refrigeration Cycle

 

Maintenance of chiller refrigeration cycle

The compressor of the chiller is a very critical component in the unit. The quality of the compressor is directly related to the stability of the unit, so it requires regular maintenance.

1. Change lubricating oil

After long-term use of the chiller refrigeration cycle, the quality of the lubricating oil will deteriorate, and the impurities and moisture inside the oil will increase, so the oil quality must be regularly observed and checked. Once a problem is discovered, it should be replaced in time. The grade of lubricant replaced must comply with the technical data.

2. Replace filter dryer

The filter dryer is an important component to ensure normal circulation of refrigerant. Since water and refrigerant are immiscible with each other, if there is moisture in the system, it will greatly affect the operating efficiency of the unit. Therefore, it is very important to keep the inside of the system dry. The filter element inside the dry filter must be replaced regularly.

3. Calibration of safety valve

The condenser and evaporator on the chiller are both pressure vessels. According to regulations, a safety valve must be installed on the high-pressure end of the unit, that is, the condenser body. Once the unit is in an abnormal working environment, the safety valve can automatically release the pressure. To prevent possible harm to the human body caused by high pressure. Therefore, regular calibration of the safety valve is very important for the safety of the entire unit.

4. Cleaning of condenser and evaporator

Since the cooling water of the water-cooled condenser is an open circulation loop, tap water is generally used for circulation through the cooling tower. When the calcium salt and magnesium salt content in the water is large, it is easy to decompose and deposit on the cooling water pipes to form scale, which affects heat transfer. Excessive scaling will also reduce the circulation cross-section of the cooling water, reduce the water volume, and increase the condensation pressure. Therefore, when the quality of the cooling water used is poor, the cooling water pipes should be cleaned at least once a year to remove scale and other dirt in the pipes. There are usually two methods for cleaning condenser water pipes:

Use a specialized pipe cleaning gun to clean the pipes.

Use a special cleaning agent to circulate and rinse, or fill it in cooling water, and then replace the solution after 24 hours until it is clean.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products up to 900 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 


 

Cooling Chillers                                                                                                     

 

recirculating chiller

Recirculating Chillers / Refrigerated Circulator

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Precision Chillers / Small ChillersWater Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6 ~ 40kW2 ~ 15kW1 ~ 8kW0.6 ~ 3kW1.5 ~ 3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

Cooling and Heating Chillers                                                                            

 

Cooling and Heating Chillers

(Custom Designs)

Temperature Control Range: -120°C to +350°C

cooling and heating thermostat, widely used in various industry.

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Recirculating Heater Chillers

(Custom Designs)

Temperature Control Range: -45°C to +250°C

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller