CDU in Data Center

Contact us today for the perfect temperature control solution

 

Data center liquid cooling solution – a full-link layout of supporting infrastructure for liquid-cooled servers. The liquid-cooled CDU distribution unit provides cooling liquid for the cold plate in the server rack, maximizing the use of the heat exchange of the liquid cooling plate to the main heat source inside the server. Cooling, reducing the use of air cooling systems, helping servers achieve greater power dissipation requirements and greater computing density in a single cabinet, further reducing PUE and assisting the high-quality development of data centers.

1. CDU in Data Center application

With its strong R&D, construction, and operation and maintenance capabilities in the field of data centers, Data has launched a new air-liquid architecture cold plate liquid-cooled CDU with a heat dissipation of up to 15kw. Relying on modular lightweight and intelligent design, the construction of edge computer rooms can be quickly completed and renovation of old computer rooms.

2. Product introduction of CDU in Data Center

CDU distribution unit liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places. It is a modular intelligent device with independent heat exchange system, power supply system and monitoring system.

3. Working principle of CDU in Data Center

The cooling water flows into the CDU distribution unit, exchanges heat with the heat transfer medium, takes away the heat of the heat transfer medium, and reaches the intended temperature. It can automatically adjust frequency according to system pressure, temperature and flow rate.

The CDU distribution unit uses liquid cooling heat exchange to cool the main heat source and reduce the use of air cooling systems. The liquid cooling equipment provides cooling fluid circulation for the heating elements, saving air heat exchange links and saving a large amount of energy consumption in the refrigeration system.

The circulation system of the CDU distribution unit adopts a fully sealed design, a magnetic drive pump, a PLC programmable controller, and a 7-inch color touch screen temperature curve display, which can be customized according to user needs.

 

ModelZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
Temp range +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
Cooling water5℃~30℃ Adopt Siemens/Honeywell regulating valve to control cooling water flow
Temperature control accuracy±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
flow control10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
The flow control is adjusted by frequency converter, the accuracy is ±0.3L/min
Cooling capacity (MAX)15kW25kW50kW75kW100kW150kW
Storage volume15L30L60L100L150L200L
BrineWater, silicone oil, fluorinated liquid, ethylene glycol aqueous solution, etc.
Medium pipelineSUS304SUS304SUS304SUS304SUS304SUS304
In and out interface sizeG3/4G1G1DN32DN40DN50
Cooling water interfaceG3/4G1DN40DN50DN50DN65
Cooling water flow 7~20℃2.5m³/h4m³/h8m³/h13m³/h17m³/h25m³/h
380V 50HZ 1kW1.5kW3kW4kW5kW6kW
shellCold-rolled sheet spray RAL7035

 

ModelZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
Temp range +5℃~35℃
Temp accuracy±0.5℃
Flow control15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
Cooling capacity(MAX) 200kW250kW300kW400kW500kW
Storage volume250L300L600L1000L1200L
MediumWater, silicone oil, fluorinated liquid, ethylene glycol aqueous solution, etc.
Medium pipelineSUS304
In and out interface sizeDN65DN65DN65DN80DN80
Cooling water interfaceDN80DN80DN100DN100DN125
Cooling water flow 7~20℃34m³/h43m³/h51m³/h69m³/h86m³/h
Power supply 380V 50HZ7kW7kW8kW9kW13kW
shellCold-rolled sheet spray RAL7035

 

CDU in Data Center

 

We provide complete temperature control system design and manufacturing. From standard models to complete customized products up to 1000 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. 

 

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller