Search Search all

Cooling Heating Temperature Control Units for Reaction Vessel

ClassificationIndustry News 127 0

Cooling Heating Temperature Control Units for Reaction Vessel

 

As a multi-functional experimental equipment that integrates heating and cooling control, cooling heating temperature control units are increasingly used in the pharmaceutical and chemical industry.

The working principle of cooling heating temperature control units mainly includes four parts: heating system, cooling system, stirring system and control system. The heating system transfers the heat generated by the electric heating wire to the medium in the reaction vessel to heat the materials in the reaction vessel; the cooling system uses water cooling or air cooling to cool the reaction vessel through circulating cooling water or air; the stirring system uses The magnetic stirring method achieves uniform mixing of the substances in the reaction vessel; the control system adopts an intelligent control system to realize automatic control of heating, cooling, stirring and other systems to improve the safety and accuracy of the experiment.

 

Cooling Heating Temperature Control Units

 

In the field of pharmaceutical and chemical industry, the application of cooling heating temperature control units is mainly reflected in the following aspects:

During the pharmaceutical preparation process, cooling heating temperature control units can provide accurate temperature control and optimize reaction conditions, thereby improving the production efficiency and quality of pharmaceuticals. For example, in the field of biopharmaceuticals, subtle changes in temperature can have a significant impact on biological activity during processes such as protein expression, enzyme-catalyzed reactions, and cell culture. By using the reaction tank high and low temperature cycle integrated machine, a stable temperature environment can be provided for the bioreactor to ensure the normal expression and function of biologically active substances.

Secondly, in the process of drug crystallization, the reaction tank high and low temperature circulation integrated machine also plays a role. The drug crystallization process is very sensitive to temperature and solvent concentration. This equipment can be used to finely control the temperature changes during the crystallization process, thereby optimizing the crystal morphology and improving drug purity and solubility.

In addition, during the extraction process of traditional Chinese medicine, the solubility of different components changes with temperature. This equipment can be used to control the temperature of the extraction process and improve the extraction rate of active ingredients and product quality.

In continuous flow chemical synthesis, the reaction tank high and low temperature cycle integrated machine also plays a role. By integrating this equipment, continuous and accurate temperature control can be achieved, reaction efficiency and safety can be improved, and continuous production can be promoted.

In general, the reaction tank high and low temperature cycle integrated machine has broad application prospects in the pharmaceutical and chemical industry due to its accurate temperature control, stirring ability and intelligent control system.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 


 

Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Heating Circulators

(Custom Designs)

  • Temperature range: +50℃ ~ +300℃
  • Large heat exchange area and fast heating speed
  • Self-diagnosis function, multiple safety protection devices
  • Closed circulation system, no oil mist at high temperatures
  • Each device is load tested for more than 12 hours
Temperature range +50°C ~ +170°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacity5.5 ~ 15kW3.5 ~ 130kW3.5 ~ 95kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

semiconductor chiller

TES Series (Temperature control for fuel and oil testing)

(Custom Designs)

  • Temperature range: -85℃ ~ +250℃
  • Siemens PLC controller and other brand accessories
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed circulation system, no oil mist at high temperatures
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacity0.3 ~ 25kW0.25 ~ 25kW3 ~ 60kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

Cooling Chillers                                                                                                     

 

recirculating chiller

Recirculating Chillers / Refrigerated Circulator

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Precision Chillers / Small ChillersMini Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6 ~ 40kW2 ~ 15kW1 ~ 8kW0.6 ~ 3kW1.5 ~ 3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message
展开更多

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller