Model | KRY-4A25W/6S | KRY-4A38W/6S | KRY-4A60W/6S |
Temp Range | -40℃~+100℃ |
Temperature control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ |
Temperature feedback | Pt100 | Pt100 | Pt100 |
Temperature display | 0.01k | 0.01k | 0.01k |
Flow control/Group | 1~20 L/min | 1~20 L/min | 1~40 L/min |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L |
Number of fluid output groups | 6 groups | 6 groups | 6 groups |
Pressure control/group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar |
Flow description | When the temperature control is lower than -30℃, the flow rate is controlled within 80% of the maximum value. |
Flow pressure description | The unit can control the flow individually or separately. Need to control different solutions at the same time (customized) |
Heating Power | 15kW | 25kW | 38kW |
cooling capacity | 100℃ | 25kW | 38kW | 60kW |
20℃ | 25kW | 38kW | 60kW |
0℃ | 25kW | 38kW | 60kW |
-20℃ | 14kW | 22kW | 35kW |
-35℃ | 5kW | 8kW | 13kW |
Compression | Emerson Valley Wheel Compressor |
Expansion valve | Electronic expansion valve |
Oil distributor | Emerson |
Dry filter, Pressure control | Danfoss |
Evaporator | plate heat exchanger |
Circulating pump | Magnetic drive pump |
Frequency converter | Delta |
Flow,Pressure sensor | Electromagnetic flowmeter, Johnson Controls pressure sensor |
Input, Display | 10 inch color touch screen \ Siemens S7-1200 PLC controller |
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol |
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection |
| device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions |
Closed circulation system | The whole system is a fully closed system, there will be no oil mist at high temperature, low temperature does not |
| absorb water in the air, the system in operation will not because of high temperature pressure rise, low temperature |
| automatically add heat conduction medium. |
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available |
Connection size | There are six groups of inlet and outlet,G3/4 |
Cooling water@20C | 8000L/H | 12000L/H | 18000L/H |
Condenser(W) | Shenshi tube type heat exchanger |
Condenser(A) | Optional air-cooled type, upper air outlet, the equipment size will be increased. |
Power 380V50HZ | 38kW max | 55kW max | 82kW max |
Dimension cm | 200*145*205 | 200*145*205 | 200*145*205 |
Weight(W) | 900kg | 1200kg | 1950kg |
Optional | 220V 60HZ Three phase 400V 50HZ Three phase 440V 60HZ Three phase |
Optional | Extend to -40~+135℃ |
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, |
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. |