Search Search all

Low Temperature Process Chillers

ClassificationIndustry News 401

Low Temperature Process Chillers

 

Low temperature process chillers are used in many industries, so there are many varieties, but because many customers do not understand the selection of chillers, when purchasing low-temperature process chillers, the operating parameters of the equipment, such as voltage , current, power, cooling capacity, pump lift, protection function, etc.

1. Classification of low-temperature process chillers: According to the type of compressor, there are three main types: piston type, screw type, and centrifugal type.

According to the cooling mode, it can be divided into three categories: water-cooled, air-cooled and evaporative.

According to the energy compensation method, it can be divided into two categories, one is the compression type, the other is the absorption type, one is to use electric energy for compensation, and the other is to use gas for compensation.

According to the sealing method, there are three types: fully enclosed, semi-closed, and open.

According to the energy usage mode, it can be divided into cooling only type, heat pump type, heat recovery type cooling only type, ice storage type and so on.

2. What parameters should be considered when choosing a low-temperature process chiller: a low-temperature process chiller is a device that can provide cooling water for the equipment to cool the equipment, thereby improving production efficiency. In the process of selecting refrigeration equipment, the first thing to consider To the working parameters and performance parameters of the refrigeration system.

Working parameters:

(1) Voltage: Chillers have 220 V (single-phase) and 380 V (three-phase), and their power supply voltage should be consistent with the required power supply voltage.

(2) Current: including rated current and real current.

(3) Power: It is the power consumption of the low temperature process chiller.

(4) Temperature: including evaporator temperature, condensing temperature, compressor suction temperature, compressor discharge temperature, intermediate temperature, refrigerant subcooling temperature before the throttle valve, compressor oil temperature in the crankcase, cooling water temperature, Chilled water temperature.

Performance parameters:

(1) Cooling capacity: also known as cooling capacity, usually expressed in kW.

(2) Cooling water flow: refers to the size of the circulating water, the number of L per minute, or the tonnage per hour.

(3) Pump head: When multiple low-temperature process chillers are connected in parallel to multiple refrigeration devices, the resistance of the piping system must be considered to calculate the required head of the pump.

(4) Control adjustment requirements: control the performance of the system, including: pressure adjustment and temperature adjustment.

 


low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Refrigerated Circulators (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller