Search Search all

Process Liquid Chillers

ClassificationIndustry News 221 0

Process Liquid Chillers

Contact us today for the perfect temperature control solution

 

Process liquid chillers are indirect cooling devices used for key equipment in semiconductor, microelectronics and other industries. Divided into open system and closed system.

The application range of process liquid chillers is very wide, involving all aspects of industrial production, including semiconductors, microelectronics, industrial refrigeration machines, steam turbine exhaust condensation in thermal power plants, large central air conditioners, coal chemical industry, petrochemical plants, natural gas pipeline cooling, etc. A large amount of process cooling water is used in all places. In many product or process production environments, clean workshops are required. The temperature and relative humidity in the workshop are required to be maintained within a certain range throughout the year. Some of the production processes generate large amounts of heat, and process equipment requires low-temperature water cooling. Even in winter, air conditioning is still required for cooling. , in order to meet these requirements, process liquid chillers must be built, which are divided into two categories: open system and closed system.

 

Process Liquid Chillers

 

The composition and working principle of process liquid chillers

Process liquid chillers consist of the following parts: chillers, pumps, heat exchangers, water tanks, filters, and process equipment.

Chiller: Provides cold source for cooling water system.

Water pump: pressurizes water to ensure its circulation in the cooling system.

Heat exchanger: This equipment is used to exchange heat between the chilled water system and the cooling water system to transfer the heat generated at the load end of the system to the chilled water system. There are many types of heat exchangers, which can be divided into shell-and-tube type, plate type, plate-fin type, heat pipe type, etc. In comparison, plate heat exchangers have the advantages of small floor space and large heat transfer area. Considering the space and cost characteristics of semiconductor factories, equipment with small floor space is preferred to save land area and project cost.

Water tank: The water tank in the open system mainly serves to supplement the water source. The water tank in a closed system needs to choose an expansion water tank. The expansion water tank has three functions. One is to contain and compensate for the expansion and contraction of water in the system; the other is to provide stable pressure to the closed circulating water system and stabilize the system pressure; The third is as an instruction for the system water replenishment pump, usually the expansion tank sends a signal to start or shut down the system water replenishment pump.

Filter: Filter out solid impurities in the water and purify the water source.

The process liquid chillers system has two relatively independent systems: chilled water and cooling water. The chilled water is provided by the chiller. The chilled water exchanges heat with the cooling water to cool down the cooling water and thereby reduce the temperature of the equipment. Water is pumped from the production equipment through the water pump to the heat exchanger to ensure the temperature of the process cooling water by controlling the amount of chilled water. After passing through the filter, it is sent to the production line equipment and then returns to the water pump. The process cooling water is circulated repeatedly. Chilled water is returned directly to the chiller.

 

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Precision Chillers / Small ChillersPrecision Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

recirculating chiller

Recirculating Chillers

(Custom Designs)

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Chillers for Automotive Test

(Custom Designs)

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.

 

 


 

Chillers for Semiconductor

(Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

 


 

Chillers for Energy Storage

 

Liquid Cooling For Battery Energy Storage Systems

(Custom Designs)

 

 

 

 

TypesFor Converting StationFor Energy Storage BatteryFor Charging Station
Cooling Capacity45kW5 ~ 8.5kW4kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

coolant distribution unit

 

ZLFQ Series

(Custom Designs)

Coolant Distribution Unit

Liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places.

 

 

 

Temperature range +5°C ~ +35°C +5°C ~ +35°C
Cooling Capacity15 ~ 150kW200 ~ 500kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

thermal chuck

 

MD Thermal Chucks Series

(Custom Designs)

It is used for testing RF devices and high-density power devices (IGBTs and MOSFETs), and can also be used for rapid cooling of laboratory flat panels (plasma, biological products, batteries), etc.

 

 

 

Temperature range -75°C ~ +225°C
Temperature accuracy±0.1℃
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


screw-chillers

 

Screw Chillers (Custom Designs)

Low temperature screw chillers and room temperature screw chillers

 

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacity107 ~ 1027kW (Single Compressor)299 ~ 2134kW (Dual Compressor)98 ~ 934kW (Single Compressor)272 ~ 1940kW (Dual Compressor)48 ~ 467kW (Single Compressor)51 ~ 497kW (Single Compressor)
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller