Search Search all

Cooling and Heating Systems in the Hydrothermal Autoclave Reactor

ClassificationIndustry News 234 0

Cooling and Heating Systems in the Hydrothermal Autoclave Reactor

Contact us today for the perfect temperature control solution

 

Cooling and heating systems in the hydrothermal autoclave reactor are heating equipment that uses water as the heat transfer medium. It uses water’s characteristics of large specific heat and fast heat transfer to transfer heat to the object being heated. In industrial production, water is widely used as a coolant and solvent in chemical processes.

For example: petroleum cracking gas to produce ethylene; methanol dehydration to produce formaldehyde; caustic soda production in the chlor-alkali industry, etc.

Hydrothermal autoclave reactors widely used in the chemical industry mainly include the following types: tubular heat exchangers; tube and tube heat exchangers; plate heat exchangers and spiral plate heat exchangers; sleeve and jacket types Hybrid heat exchangers; circulating fluidized bed reactors with internal cooling and external heating; fixed bed reactors and other types of special structure hydrothermal autoclave reactors, etc.

 

Cooling and Heating Systems in the Hydrothermal Autoclave Reactor

 

Cooling and heating systems in the hydrothermal autoclave reactor

1. Natural cooling

The natural cooling method of hydrothermal autoclave reactor is to allow the kettle body to naturally dissipate heat. When the reaction is completed, turn off the heater and stirrer and allow the kettle to cool naturally. This method is suitable for situations where the reaction temperature is not too high. Generally, the temperature can be lowered to below room temperature, but it takes a long time and requires patience.

2. Water cooling

Water cooling is a common cooling method and one of the faster and more effective methods. The specific operation method is: after the reaction is completed, first turn off the heater and stirrer, then connect the cooling water pipe, flow the cooling water into the reaction kettle through the cooling jacket, and circulate the cooling until the temperature of the kettle body drops to the required temperature.

It should be noted that when using water cooling, pay attention to the flow and temperature of the water to avoid problems of too low or too high temperature. In addition, use high-quality cooling water to avoid negative effects on the reaction.

3. Air cooling

Gas cooling is a cooling method suitable for high temperature reactions. The specific operation method is: after the reaction is completed, turn off the heater and stirrer, then flow the inert gas (such as nitrogen) into the reaction kettle through the cooling jacket, and circulate the cooling until the kettle temperature drops to the required temperature.

It should be noted that when using gas exhaust, prevent gas leakage and maintain good ventilation. At the same time, use high-quality inert gases and avoid adverse effects on the reaction.

In short, different cooling methods can be selected according to the needs of different reactions. At the same time, ensuring the normal operation of the reactor equipment also requires regular maintenance of the equipment.

 

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Cooling and Heating Systems (SUNDI series)

(Custom Designs)

Temperature Control Range: -120°C to +350°C

cooling and heating thermostat, widely used in various industry.

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Cooling and Heating Systems (WTD series)

(Custom Designs)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Cooling and Heating Circulators

(Custom Designs)

Temperature Control Range: -45°C to +250°C

 

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Heating Circulators

(Custom Designs)

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +170°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacity5.5 ~ 15kW3.5 ~ 130kW3.5 ~ 95kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

TCU Multi-reactors Temperature Control System

(Custom Designs)

Temperature Control Range: -120°C to +250°C

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

 

Cooling Chillers                                                                                                     

 

recirculating chiller

Recirculating Chillers / Refrigerated Circulator

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Precision Chillers / Small ChillersWater Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller