Closed Recirculating Cooling System

ClassificationIndustry News 235 0

Closed Recirculating Cooling System

Contact us today for the perfect temperature control solution

 

A closed recirculating cooling system is a machine used for low-temperature refrigeration. It uses static refrigeration to achieve cooling effect by circulating refrigerant. Closed recirculating cooling systems are often used in industrial fields such as laboratories, pharmaceutical factories, and food processing plants. Single-stage, double-stage, three-stage or even four-stage refrigeration can be selected according to actual needs. Different refrigeration levels can meet different cooling needs. The operation of the closed recirculating cooling system is composed of three interrelated systems: the refrigerant circulation system, the water circulation system, and the electrical automatic control system.

 

Closed Recirculating Cooling System

 

1. Refrigerant circulation system:

The liquid refrigerant in the evaporator in the refrigerant cycle system absorbs the heat in the water and begins to evaporate. Eventually, a certain temperature difference is formed between the refrigerant and the water. The liquid refrigerant also completely evaporates into a gas state and is sucked into the compressor and compressed (pressure and temperature increase), the gaseous refrigerant absorbs heat through the condenser (air-cooled/water-cooled), condenses into a liquid, and becomes low-temperature and low-pressure refrigerant after being throttled by the thermal expansion valve (or capillary tube) and enters the evaporator to complete the refrigerant cycle process .

2. Water circulation system:

The liquid refrigerant in the evaporator absorbs the heat of the object being cooled and vaporizes into low-pressure, low-temperature steam. The object being cooled in a chiller is water. When the refrigerator is running, turn on the cold water pump, and water will continuously circulate between the water tank and the evaporator to reduce the water temperature to the set temperature.

The water circulation system pump is responsible for pumping water from the water tank to the equipment that the user needs to cool. The chilled water takes away the heat and the temperature rises, and then returns to the chilled water tank.

3. Electrical automatic control system:

The electrical automatic control system includes the power supply part and the automatic control part. The power supply part supplies power to compressors, fans, water pumps, etc. through contactors. The automatic control part includes a thermostat, pressure protection, delayer, relay, overload protection, etc. that are combined to achieve functions such as automatic start and stop protection based on water temperature.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products up to 900 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Cooling Chillers                                                                                                     

 

recirculating chiller

Recirculating Chillers / Refrigerated Circulator

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Precision Chillers / Small ChillersWater Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6 ~ 40kW2 ~ 15kW1 ~ 8kW0.6 ~ 3kW1.5 ~ 3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

Cooling and Heating Chillers                                                                            

 

Cooling and Heating Chillers

(Custom Designs)

Temperature Control Range: -120°C to +350°C

cooling and heating thermostat, widely used in various industry.

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Recirculating Heater Chillers

(Custom Designs)

Temperature Control Range: -45°C to +250°C

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller