Air Cooled and Water Cooled Chillers

ClassificationIndustry News 338

Air Cooled and Water Cooled Chillers

 

Industrial chillers are divided into two categories, namely air-cooled chillers and water-cooled chillers. First of all, you need to determine which type you need, and you must also understand the differences between the two cooling methods, as well as price comparisons. .

The air-cooled chiller mainly consists of four main components: compressor, evaporator, condenser, and throttling device. Air-cooled chillers have the advantages of easy installation and no need for cooling tower systems, and are widely used in various industries.

1. The air-cooled chiller adopts a finned condenser, which directly uses the fan to take away the heat of the refrigerant, so no other auxiliary equipment is needed, which saves the need to install a cooling pipeline system. And it has certain advantages in installation, especially for small chillers, it is more convenient when it needs to be moved.

2. The condensing temperature of the air-cooled chiller is higher than that of the water-cooled chiller during operation. Under the same cooling capacity, the power consumption of the air-cooled chiller will be higher, and the air-cooled chiller is higher than the water-cooled chiller. The cooling capacity of the traditional type is about 300 to 500Kcal/h higher.

3. The air-cooled chiller uses a finned condenser, which is greatly affected by the accumulation of dust and scale, so the finned tubes should be cleaned regularly to avoid clogging.

The water-cooled chiller mainly uses water to dissipate heat. It uses a shell-and-tube evaporator to exchange heat between water and refrigerant. The refrigerant system absorbs the heat load in the water and cools the water to produce cold water. It is brought to the shell-and-tube condenser, and the refrigerant exchanges heat with water, so that the water absorbs the heat and then takes the heat out to the external cooling tower (belonging to water cooling) through the water pipe.

1. The water-cooled chiller is safer in operation than the air-cooled chiller, and it is more convenient for maintenance.

2. The power consumption of water-cooled chillers is less than that of air-cooled chillers, and the power consumption of water-cooled chillers is only about 70% of that of air-cooled chillers.

3. The built-in automatic water supply device saves installation and maintenance, and is especially suitable for other special occasions such as large temperature difference and small flow.

In fact, both air-cooled chillers and water-cooled chillers have their own application advantages. When choosing a chiller, you can choose a suitable type of industrial chiller based on your own environment, price and cost, and other factors.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller