Air Cooled Unit
In the industrial refrigeration industry, friends often ask how to choose an air cooled unit. After comparing the chiller solutions of two or three companies, they feel that they are similar, but the prices are very different! Therefore, it is really necessary for enterprise producers to understand the basic selection common sense of air cooled unit. So how can you choose the air cooled unit solution that suits you for enterprise production? Below we will explain to you from six aspects.
1. How many parameters do you need?
For example, how much material and how long do you need to cool down to how much ℃? This is an important reference for us to choose the type of air cooled unit. In addition to the temperature difference, other cooling parameters include water flow, water pressure, cooling time, and material volume. These parameters are used to calculate the cooling capacity required by the production equipment.
2. Consider solutions with low energy consumption
If you are a large air cooled unit, pay attention to the energy consumption and choose a chiller scheme that comprehensively utilizes electric heating and cooling.
3. Do you need other chillers to work together?
See if your business needs multiple air cooled units, such as cold storage, which require stable and continuous cooling. When a certain air cooled unit fails, other chillers are needed to work instead. According to the production situation of your enterprise, explain it to the manufacturer.
4. Are there any environmental protection requirements?
Air cooled unit work will also cause some environmental problems, such as whether the refrigerant is toxic, whether the operating noise is loud, and whether it will affect the surrounding environment of the enterprise. When selecting equipment, the requirements in this regard must be clearly explained to the manufacturer .
5. Cooling water quality requirements
The water quality of the cooling water will affect the cleanliness of the pipeline, especially the evaporator. Poor cooling water quality will accelerate the scaling and corrosion of the pipeline, resulting in the blockage and damage of the evaporator. Please inform the manufacturer when selecting the model.
6. Other special requirements such as explosion-proof and vibration
The air cooled unit often works in a harsh environment and is often exposed to special substances such as flammable dust and explosive gas. Then the enterprise’s requirements for explosion-proof and shock-proof will also increase. At this time, it is necessary to consult the relevant technical personnel of the enterprise, whether the working environment of the chiller is flammable and explosive, and consult with the chiller manufacturer, whether the air cooled unit can be used for explosion-proof treatment, explosion-proof level For how much, the overall cooling needs match the appropriate chiller solution.
If your company needs to be equipped with customized air cooled units during the production process, you can consider the actual situation of your company in advance, start from the above six points, formulate a demand plan for chillers, and choose to cooperate with air cooled unit manufacturers with complete brand qualifications and reputations.
Customized Solutions For Your Business
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -150°C to -5°C
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW |
Recirculating Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers
Temperature Control Range: +5°C to +50°C
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments
Temperature Control Range: -120°C to -10°C
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Direct Cooling Ultra Low Temp Chillers
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperature range | -150°C ~ -110°C |
Cooling Capacity | up to 11kW |
Screw Chillers
Low temperature screw chillers and room temperature screw chillers
Customized solutions for your business.
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |