Model | GD-9000-2-B1-KRYCH-4A15W | GD-9000-2-B1-KRYCH-475W | GD-9000-2-B1-KRYCH-4A10W | GD-1000-B1-KRYCH-475 |
Temperature range | -40℃~100℃ Antifreeze | -40℃~100℃ Test chamber | -40℃~100℃ Antifreeze | -40℃~100℃ Test chamber | -40℃~100℃ Antifreeze | -40℃~100℃ Test chamber | -40℃~100℃ Antifreeze | -40℃~100℃ Test chamber |
Antifreeze flow control | 1L/min~40L/min | | 1L/min~25L/min | | 1L/min~25L/min | | 1L/min~10L/min | |
Antifreeze flow control accuracy | ±0.2L/min | ±0.2L/min | ±0.2L/min | ±0.2L/min |
Antifreeze pressure | Measure and display the inlet and outlet pressure and display the pressure on the touch screen |
Test chamber size (W*H*D) | Upper cavity (cm) | 220*322*120 | 220*322*120 | 220*322*120 | Single cavity: 100*100*100 |
Lower cavity (cm) | 220*322*110 | 220*322*110 | 220*322*110 |
Heating capacity (kW) | 15 | 14 | 7.5 | 14 | 10 | 14 | 7.5 | 6 |
Cooling capacity (kW) Antifreeze | 135℃ | 15 | 7.5 | 10 | 7.5 |
20°℃ | 15 | 7.5 | 10 | 7.5 |
0℃ | 15 | 7.5 | 10 | 7.5 |
-20℃ | 10 | 4.5 | 6 | 4.5 |
-35℃ | 4 | 1.8 | 2.5 | 1.8 |
Test chamber | Heating rate | 25~+100℃≥±2℃/Min (no load, full-time average) (5~25℃ can be customized) |
Cooling rate | 25~-40℃≥1℃/Min (no load, average over the whole process) (5~25℃ can be customized) |
Antifreeze temperature control accuracy | ±0.1℃ |
Temperature uniformity of high and low temperature chambers | ≤±1℃ (no load) |
Circulation air volume | 5000m³/h | 2500m³/h |
Control method | Segmented fuzzy PID algorithm control |
Communication protocol interface | CAN/TCP/RS485 |
Internal temperature feedback of the equipment | Equipment box internal temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (water cooling equipment has) |
High temperature cooling module | Can cool down from high temperature 100℃ |
Circulation pump | Magnetic drive pump |
compressor | Brand inverter compressor |
Evaporator | Plate/Fin Heat Exchanger |
Refrigeration accessories | Emerson/Danfoss brand filter drier, oil separator, etc. |
Throttling method | Electronic expansion valve |
Refrigerant | R125/R404A |
Safety protection | Phase sequence failure protector, refrigerator overload protection; high pressure switch, overload relay, thermal protection device and other safety protection functions. |
Water-cooled condenser | Jacket/shell and tube heat exchanger |
Operation panel | 10-inch color touch screen, temperature curve display\EXCEL data export | 7-inch color touch screen, temperature curve display\EXCEL data export |
Internal reserved antifreeze interface | ZG3/4 | ZG3/8 |
Cooling water @20℃ | 25m3/H | 20m3/H | 20m3/H | 7m3/H |
Overall dimensions (W*H*D)cm | 240*560*285 | 240*560*285 | 240*560*285 | 120*205*205 |
Inner bottom plate load bearing | 1500kg | 1500kg | 1500kg | 120kg |
Weight | 4600kg | 4200kg | 4200kg | 600kg |
Power supply | 380V 50HZ |
Insulation material | Glass fiber wool & polyurethane |
Inner box material | SUS304 stainless steel brushed plate |
Outer box material | Cold rolled steel plate + plastic spraying |
Execution meets standards | GB/T 2423.1;GB/T 2423.2;GB/T 2423.3;GB/T 2423.4;GB/T 5170.2;GB/T 5170.5;GB/T 11158;GB/T 10589;GB/T 10592; GB/T 10586;IEC 60068 |