Chemical Reactor Thermal Control Units
With the continuous development of science and technology, the improvement of performance and efficiency of reactors, as reaction equipment in chemical, pharmaceutical, food and other industries, has become the focus of the industry. Among them, chemical reactor thermal control units, as important auxiliary equipment of the reactor, play a vital role in the reaction process.
Basic principles of chemical reactor thermal control units
Chemical reactor thermal control units mainly achieve accurate control of the material temperature in the reactor by controlling the fluid temperature in the heat exchanger. Its working principle is based on the principles of heat conduction and convection. By adjusting the fluid flow and temperature in the heat exchanger, it can achieve rapid and stable control of the temperature of the materials in the reactor.
Application of chemical reactor thermal control units in reaction process
1. Ensure stable reaction conditions: During the chemical reaction process, chemical reactor thermal control units can ensure the stability of the temperature during the reaction process, thereby ensuring the stability of the reaction conditions and improving product quality and yield.
2. Improve reaction efficiency: By accurately controlling the reaction temperature, the chemical reaction rate can be accelerated or slowed down, thereby improving reaction efficiency. Chemical reactor thermal control units can quickly respond to temperature changes to ensure that the reaction proceeds at the right temperature, thereby improving reaction efficiency.
3. Ensure production safety: Certain chemical reactions may cause danger at high or low temperatures, such as explosions, combustion, etc. Chemical reactor thermal control units can ensure that the reaction temperature fluctuates within a safe range, thereby ensuring production safety.
Chemical reactor thermal control units can ensure the stability of reaction conditions, improve reaction efficiency, and ensure production safety by accurately controlling the reaction temperature during the reaction process.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Heating Circulators
- Temperature range: +50℃ ~ +300℃
- Large heat exchange area and fast heating speed
- Self-diagnosis function, multiple safety protection devices
- Closed circulation system, no oil mist at high temperatures
- Each device is load tested for more than 12 hours
Temperature range | +50°C ~ +170°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) | ||||||
Heating Capacity | 5.5 ~ 15kW | 3.5 ~ 130kW | 3.5 ~ 95kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TES Series (Temperature control for fuel and oil testing)
- Temperature range: -85℃ ~ +250℃
- Siemens PLC controller and other brand accessories
- Self-diagnosis function, multiple safety protection devices
- Fully closed circulation system, no oil mist at high temperatures
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series | ||||||
Cooling Capacity | 0.3 ~ 25kW | 0.25 ~ 25kW | 3 ~ 60kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chillers / Refrigerated Circulator
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Mini Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6 ~ 40kW | 2 ~ 15kW | 1 ~ 8kW | 0.6 ~ 3kW | 1.5 ~ 3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |