Search Search all

Chiller 10 Toneladas

ClassificationIndustry News 181 0

Chiller 10 Toneladas

Contact us today for the perfect temperature control solution

 

Components of chiller 10 toneladas

Compressor: Responsible for compressing the refrigerant and increasing its temperature and pressure.

Condenser: used for heat exchange between refrigerant and cooling water to condense the refrigerant into liquid.

Expansion valve: Responsible for reducing the pressure of the refrigerant to form a low-temperature and low-pressure liquid-gas mixture.

Evaporator: used for the refrigerant to absorb the heat of the cooling water to prepare cold water.

Control system: including temperature sensors, pressure sensors, liquid level gauges, etc., responsible for monitoring and adjusting the operating status of the entire system.

 

Chiller 10 Toneladas

 

Chiller 10 toneladas features and benefits

1. Compact structure and smooth operation.

The condenser and dry evaporator of chiller 10 toneladas adopt high-efficiency heat transfer tubes, and the main engine adopts imported high-efficiency semi-hermetic twin-screw compressor, which has many advantages such as compact structure, small size, light weight, and small installation location. The semi-hermetic twin-screw compressor has few moving parts. The compressor uses a 5:6 ultra-efficient screw rotor. There is no direct wear between the rotors and it has high reliability. Since the screw machine is a continuous compressor without pulsation, the unit has the characteristics of stable performance, low noise, small vibration and smooth operation. The efficiency is 20%-30% higher than that of reciprocating compressors.

2. Complete energy control system.

The chiller 10 toneladas has a four-level capacity control system that automatically adjusts the start and stop of the unit according to load changes, making it more energy-saving. During operation, the computer control system will change the energy output of the unit according to changes in the client’s heat load. The microcomputer quickly determines and sends a signal to push the slide valve to the required energy by monitoring the difference between the measured actual load and the user’s setting. And in multiple systems, it works in an optimized way with the lowest power consumption at the best cooling capacity. It not only shows excellent performance at full load, but also has high operating efficiency even at partial load.

3. Independent refrigeration cycle system.

chiller 10 toneladas have two or more independent refrigeration circuits. Even if one circuit fails or is under maintenance, the other circuit can still operate normally. With backup function, it is especially suitable for use in industrial non-stop environments.

 

Chiller 10 Toneladas

 

4. Easy and intuitive operation.

The chiller 10 toneladas uses a microcomputer programmable controller with a touch screen display. Follow the menu selections on the screen and touch the display button on the screen directly with your finger to start the unit. The screen can display the operating status of the unit at any time, and can display parameters in graphics and text tables at a glance.

5. Protection function of microcomputer controller.

It has the protection of compressor coil temperature being too high, oil preheating timer switch, cold water flow switch, cold water outlet temperature too low protection, exhaust temperature too high protection, compressor overload protection, power failure memory function, frequent start and stop protection, Protection functions such as voltage abnormality protection, low oil level protection, high and low voltage protection, etc.

6. Multiple protections, safe and reliable.

chiller 10 toneladas In addition to the internal protection module of the compressor providing over-under-voltage, phase loss, overload and other functions to protect the compressor, the pressure control and other devices of the refrigeration system can make the unit work foolproof.

7. Freezing medium.

The chiller 10 toneladas uses ethylene glycol antifreeze, and can also be designed to use salt water as antifreeze according to user requirements.

8. Easy to install.

The chiller 10 toneladas has completed all component installation, operation testing, and has been filled with refrigerant and refrigeration oil in the factory. Users only need to connect water lines and electrical circuits before it can be put into use, reducing installation and debugging time.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products up to 900 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Cooling Chillers                                                                                                     

 

recirculating chiller

Recirculating Chillers / Refrigerated Circulator

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Precision Chillers / Small ChillersWater Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

Cooling and Heating Chillers                                                                            

 

Cooling and Heating Chillers

(Custom Designs)

Temperature Control Range: -120°C to +350°C

cooling and heating thermostat, widely used in various industry.

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Recirculating Heater Chillers

(Custom Designs)

Temperature Control Range: -45°C to +250°C

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Request a Quote
Name
Email Address
Phone
Company
Please fill in your requirements
Request A Quote

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller