Chiller 5 hp – Water Chiller Manufacture
The 5 hp chiller needs to be strictly debugged before leaving the factory (the debugging time is not less than 24 hours), and only after correct debugging can the normal operation of the equipment be guaranteed.
Commissioning preparations for a 5 hp chiller
1. Check whether the installation of the 5 hp chiller meets the technical requirements, and whether the connecting pipeline, size, specification, material, etc. meet the requirements.
2. Check whether the circuit system of the 5 hp chiller meets the requirements and is normal.
3. Carry out the water flow test, flush the dirt in the water system, check whether the water pump is normal, whether the circulating water volume meets the requirements of the working conditions, etc.
4. Check whether the pressure gauge, temperature gauge and sensor on the pipeline are normal.
5. Check whether the water pressure in the pipeline is in a normal state.
6. Safety protection equipment needs to be prepared during operation
debugging
1. Check whether the valves are in the normal open state, and do not close them.
2. Check whether the power supply voltage is normal.
3. After starting the 5 hp chiller, check whether the parameters of the equipment are normal.
4. Record the various data of the 5 hp chiller.
5. During the commissioning and operation of the equipment, pay attention to whether the compressor is working normally.
6. If there is an abnormal situation during debugging, stop the machine immediately and check it.
7 hp chiller must be cleaned and dried inside before debugging. If the cleaning is not clean, it will cause various failures during debugging.
Customized Solutions For Your Business
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -150°C to -5°C
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW |
Recirculating Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers
Temperature Control Range: +5°C to +50°C
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments
Temperature Control Range: -120°C to -10°C
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Direct Cooling Ultra Low Temp Chillers
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperature range | -150°C ~ -110°C |
Cooling Capacity | up to 11kW |
Screw Chillers
Low temperature screw chillers and room temperature screw chillers
Customized solutions for your business.
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |