Circulating low temperature refrigeration system is also called a low-temperature chiller. It usually refers to a unit with a water temperature of -60°C to 5°C. It is generally used in various industrial production lines that require low temperatures. In fact, low-temperature units are a large category. If subdivided, they are divided into water-cooled and air-cooled types according to different cooling forms. According to different compressors, they are divided into screw type, scroll type and piston type.

Characteristics of circulating low temperature refrigeration system

1. Reliable performance, energy saving and environmental protection

The compressor of the circulating low temperature refrigeration system adopts a semi-closed screw type and has built-in advanced components such as oil filter, oil separator, safety pressure reducing valve, suction filter and protection module to ensure stable performance and no leakage during the operation of the equipment. Low energy consumption.

2. Multiple refrigerants available

In addition to R22 refrigerant, environmentally friendly refrigerants such as R134A or R407C can also be selected according to customers’ different usage scenarios and needs.

 

Circulating Low Temperature Refrigeration System

 

3. Low noise and smooth operation

Since the compressor of the circulating low temperature refrigeration system consumes a large amount of lubricating oil and supplies oil with a low pressure difference, the lubricating oil has high oil separation efficiency and can absorb the noise of the unit’s operation. In addition, the circulating low temperature refrigeration system uses a high-precision and high-stability compressor, so the unit runs smoothly, has low vibration, and the noise is much smaller, effectively reducing interference to the outside world and improving the unit’s operational stability.

4. High automation, easy to operate

The circulating low temperature refrigeration system has a built-in microcomputer automatic control system, which can directly control the unit through the touch screen to ensure the safety and stability of the unit, which reflects its advanced nature. The display screen will present each parameter setting value, operation status, alarm status and historical records of the unit in real time, making it easy for the operator to understand and operate.

5. Easy to install, simple and fast

When installing the circulating low temperature refrigeration system, you only need to connect water and electricity on site, and charge an appropriate amount of refrigerant into the equipment. After debugging according to the set values, it can be put into operation. No traditional equipment is required, and a lot of on-site installation work is also eliminated. .

6. High heat exchange efficiency

The circulating low temperature refrigeration system has been updated and optimized to optimize the internal heat exchange system. This change has greatly improved the heat exchange efficiency of the equipment.

7. Low consumption, saving refrigerant

The circulating low temperature refrigeration system uses a dry evaporator, which not only greatly reduces the amount of refrigerant injected, but also eliminates the need for an oil pump and makes oil return simple.

8. Long service life

With multiple built-in compressors, the circulation circuits of each compressor can operate independently without interfering with each other, extending the service life of the unit.

9. Strong compatibility and wide application range

In addition, the circulating low temperature refrigeration system needs to be cleaned regularly, at least once a month. Especially if it is going to be out of service for a long time, it must be cleaned carefully from the inside out. For example, major components such as refrigeration compressors and coolers, as well as components such as filter surfaces and pipelines that are prone to residual impurities. Insufficient cleaning will cause excessive stains to accumulate in the equipment, affecting the efficiency of the equipment. After cleaning, it is best to seal and store the low-temperature unit to prevent dust and impurities from entering.

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Precision Chillers / Small ChillersPrecision Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

recirculating chiller

Recirculating Chillers

(Custom Designs)

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

 

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Chillers for Automotive Test

(Custom Designs)

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.

 

 


 

Chillers for Semiconductor

(Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

 


 

Chillers for Energy Storage

 

Liquid Cooling For Battery Energy Storage Systems

(Custom Designs)

 

 

 

 

 

TypesFor Converting StationFor Energy Storage BatteryFor Charging Station
Cooling Capacity45kW5 ~ 8.5kW4kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

coolant distribution unit

 

ZLFQ Series

(Custom Designs)

Coolant Distribution Unit

Liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places.

 

 

 

Temperature range +5°C ~ +35°C +5°C ~ +35°C
Cooling Capacity15 ~ 150kW200 ~ 500kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

thermal chuck

 

MD Thermal Chucks Series

(Custom Designs)

It is used for testing RF devices and high-density power devices (IGBTs and MOSFETs), and can also be used for rapid cooling of laboratory flat panels (plasma, biological products, batteries), etc.

 

 

 

Temperature range -75°C ~ +225°C
Temperature accuracy±0.1℃
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


screw-chillers

 

Screw Chillers (Custom Designs)

Low temperature screw chillers and room temperature screw chillers

 

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacity107 ~ 1027kW (Single Compressor)299 ~ 2134kW (Dual Compressor)98 ~ 934kW (Single Compressor)272 ~ 1940kW (Dual Compressor)48 ~ 467kW (Single Compressor)51 ~ 497kW (Single Compressor)
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller