Closed Recirculating Cooling Water Systems
Contact us today for the perfect temperature control solution
The main function of closed recirculating cooling water systems is to use cooling water to cool the internal circulating media of various heating equipment, such as metallurgical blast furnaces, smelting furnaces, heat treatments, steam turbines, generators, air conditioning hosts, fans, compressors, industrial appliances, A system for cooling quenching fluid, hydraulic oil, etc.
During the cooling process, closed recirculating cooling water systems are completely isolated from the outside world, that is, they have no contact with the heat-exchanging air. They have no direct heat exchange with the air and are completely isolated from the outside air. This ensures the purity and non-destructive nature of the circulating water or circulating medium.
Structure of closed recirculating cooling water systems
Generally, closed recirculating cooling water systems consist of industrial heating equipment, closed cooling towers, circulation pumps, system pipes and water tanks.
The functions and processes of each part in closed recirculating cooling water systems
Industrial heating equipment is equipment that produces heat and needs to be cooled. There is a circulating medium passing through it and it is heated.
A closed cooling tower is a device that dissipates heat. It transfers heat to the atmosphere. It is a heat dissipation terminal device in which the circulating medium is cooled and cooled.
Circulation pump is the source of power that drives the flow of circulating media.
System pipes are blood vessels, spaces where circulating media flows, connecting various components.
A water tank is a container used to stabilize pressure and supplement media.
Features and advantages of closed recirculating cooling water systems
1. No evaporation. Due to complete sealing, there is no evaporation, ensuring that the number of circulating media remains unchanged.
2. No scaling. For circulating water, since there is no evaporation and the concentration of various ions inside remains unchanged, scaling will not occur.
3. No impurities. Since it is completely isolated from the outside world, no external impurities can enter, ensuring the purity of the medium. Suitable for cooling various flowing media.
4. Energy saving, because the fan and spray can be automatically controlled to start and stop according to the temperature, reducing energy consumption.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products up to 900 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Recirculating Chillers / Refrigerated Circulator
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Water Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6 ~ 40kW | 2 ~ 15kW | 1 ~ 8kW | 0.6 ~ 3kW | 1.5 ~ 3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Chillers
Temperature Control Range: -120°C to +350°C
cooling and heating thermostat, widely used in various industry.
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Heater Chillers
Temperature Control Range: -45°C to +250°C
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |