Cryogenic Freezing Systems
Contact us today for the perfect temperature control solution
Cryogenic freezing systems are a commonly used refrigeration equipment. Its main function is to evaporate low-temperature refrigerant into the evaporator through an expansion valve and other devices, thereby absorbing heat and achieving a refrigeration effect.
1. Refrigerant selection
In cryogenic freezing systems, commonly used refrigerants include R404A, R507, etc. These refrigerants have lower saturated steam temperature and higher refrigeration efficiency, and can meet the refrigeration requirements under low temperature conditions.
2. Refrigeration cycle
The refrigeration cycle of cryogenic freezing systems includes four processes: compression, condensation, expansion and evaporation. The refrigeration cycle consists of a compressor, condenser, expansion valve and evaporator. Among them, the compressor compresses the low-temperature refrigerant into high-temperature and high-pressure gas, the condenser cools the high-temperature and high-pressure gas into high-pressure liquid, and the expansion valve expands the high-pressure liquid into low-pressure liquid and passes the refrigerant in the evaporator to finally achieve the refrigeration effect.
3. Evaporation process
Evaporation is the key process of refrigeration in cryogenic refrigeration units. In the evaporator, low-temperature refrigerant enters through an expansion valve and other devices, causing the refrigerant to evaporate at low temperatures and absorb the surrounding heat to achieve the purpose of refrigeration. At the same time, the temperature of the refrigerant will gradually increase during the evaporation process. When it reaches a certain temperature, it will re-enter the compressor and start the next refrigeration cycle.
4. Temperature control
Cryogenic freezing systems require precise temperature control during use to achieve good refrigeration effects. Under normal circumstances, by receiving the signal returned by the temperature sensor, the opening of the expansion valve is automatically controlled to achieve the required temperature control purpose.
In short, the refrigeration principle of cryogenic freezing systems not only requires the selection of refrigerant, but also requires precise control of various parameters of the refrigeration cycle to achieve the best refrigeration effect.
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Precision Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chillers
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Liquid Cooling For Battery Energy Storage Systems
Types | For Converting Station | For Energy Storage Battery | For Charging Station | ||||||
Cooling Capacity | 45kW | 5 ~ 8.5kW | 4kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
ZLFQ Series
Coolant Distribution Unit
Liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places.
Temperature range | +5°C ~ +35°C | +5°C ~ +35°C | |||||||
Cooling Capacity | 15 ~ 150kW | 200 ~ 500kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
MD Thermal Chucks Series
It is used for testing RF devices and high-density power devices (IGBTs and MOSFETs), and can also be used for rapid cooling of laboratory flat panels (plasma, biological products, batteries), etc.
Temperature range | -75°C ~ +225°C | ||||||||
Temperature accuracy | ±0.1℃ | ||||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Screw Chillers (Custom Designs)
Low temperature screw chillers and room temperature screw chillers
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C | |||
Cooling Capacity | 107 ~ 1027kW (Single Compressor) | 299 ~ 2134kW (Dual Compressor) | 98 ~ 934kW (Single Compressor) | 272 ~ 1940kW (Dual Compressor) | 48 ~ 467kW (Single Compressor) | 51 ~ 497kW (Single Compressor) | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |