100 Ton Chiller – Industrial Water Chiller Factory
In summer, many companies need to run chillers 24 hours a day, so the utilization rate is very high. However, after entering autumn and winter, enterprises in some areas no longer need chillers for cooling, but only need to cool through cooling water towers. When the enterprise stops using the 100 ton chiller, it is still necessary to do a good job in the maintenance of the chiller to facilitate the normal operation of the chiller in the next year.
100 ton chiller cleaning steps
1. Turn off the water source of the chiller, and clean up the water inside the equipment components and pipes, so as to avoid the remaining water from corroding the unit components after shutdown, or the temperature is too low to freeze the copper pipes; at the same time, unscrew the drain nut under the water pump to drain the water inside Drain the remaining water to prevent the water system from freezing due to low ambient temperature, the evaporator bursting and causing refrigerant leakage or water pump impeller damage and other failures.
2. Turn off the power of the 100 ton chiller, and check whether each part is worn (if any, it needs to be replaced).
3. Clean the fan of the air-cooled 100 ton chiller and keep it in a clean state.
4. For the water tank of the water tank coil evaporator, check whether there are scales and other debris and remove them.
5. Understand the use of lubricating oil through data records, and regularly replace lubricating oil according to the usage standards to maintain a good lubrication state.
Maßgeschneiderte Lösungen für Ihr Unternehmen
Niedertemperatur-Kühlgeräte (wasser- oder luftgekühlt)
Ultra-Niedrigtemperatur-Kaskaden-Kältetechnik.
Für jedes Temperatursegment stehen Ihnen mehr als ein Dutzend Produktmodelle zur Auswahl.
Temperaturbereich | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C | Serie -150°C ~ -110°C |
Kühlleistung | 3 ~ 103 Tonnen | 1,5 ~ 103 Tonnen | 1,5 ~ 103 Tonnen | 1,1 ~ 77 Tonnen | 0,5 ~ 52 Tonnen | 0,7 ~ 3,2 Tonnen |
Rückkühler (Wassergekühlt oder luftgekühlt)
Geschlossene Zirkulationsleitung, Ethylenglykol gemischt mit Wasser zur Kühlung.
Temperaturbereich | Serie -25°C ~ +30°C | -45°C ~ +30°C Reihe | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Kühlleistung | 0,2 ~ 11 Tonnen | 0,1 ~ 3,5 Tonnen | 0,1 ~ 2,1 Tonne | 0,05 ~ 2,1 Tonne | 0,08 ~ 2,5 Tonne |
Raumtemperatur-Kühlgeräte / Kleinkühlgeräte
Hochpräzises System zur Regelung der Kühltemperatur.
Temperaturbereich | -18°C ~ +30°C | +5°C ~ +35°C Reihe |
Kühlleistung | 0,09 ~ 0,26 Tonne | 0,5 ~ 15 Tonnen |
Kühlgeräte mit direkter Kühlung
Er eignet sich für Orte mit kleiner Wärmeaustauschfläche und großem Wärmeaustausch.
Temperaturbereich | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Leistung des Kompressors | bis zu 8HP | bis zu 8HP*2 | bis zu 45HP*3 |
Direktkühlende Ultra-Niedrigtemperatur-Kühlgeräte
Der Ultra-Niedrigtemperatur-Direktkühler verwendet die sekundäre Unterkühlungstechnologie, und die Kühlgeschwindigkeit ist schnell. Das Kältemittel im Kältesystem wird direkt ausgegeben und verdampft in das Zielsteuerelement (Wärmetauscher) zur Kühlung.
Temperaturbereich | -150°C ~ -110°C |
Kühlleistung | bis zu 11kW |