Suche Alle suchen

3 Kühlungsmethoden für das Wärmemanagement von Energiespeicherbatterien

KlassifizierungIndustrie-Nachrichten 355 0

3 Kühlungsmethoden für das Wärmemanagement von Energiespeicherbatterien

Kontaktieren Sie uns noch heute für die perfekte Lösung zur Temperaturkontrolle

 

In the energy storage industry, the attention paid to thermal management is relatively high. The cooling methods of energy storage thermal management mainly include air cooling, liquid cooling, phase change cooling, and heat pipe cooling.

1. Air cooling technology

At present, air cooling technology is mainly used in container energy storage systems with low power density and communication base station energy storage systems. On the one hand, it is because the structure of the air-cooling system is simple, reliable, and easy to implement; on the other hand, because the energy storage system is not as strict as the power battery system on energy density and space, it can be obtained by increasing the number of batteries to achieve a lower working temperature. rate and heat production rate.

The air-cooled heat management system has an air-conditioning structure, including a floor-standing integrated type, a top-mounted integrated type, and a split type. The floor-standing integrated air conditioner is used in the energy storage container with reserved air-conditioning space. Usually, the air comes out from the top and is connected to the air duct inside the container to directly supply air to the battery pack accurately.

If there is no space to install an air conditioner inside the energy storage container, a top-mounted integrated air conditioner is required. The air conditioner is installed on the top of the container to cool the battery from the top.

The internal unit of the split air conditioner is installed in the battery pack, and the air is returned from the front to the back, and the air outlet of the air conditioner is connected to the air duct to directly cool the battery.

 

luftgekühlt

 

 

2. Liquid cooling technology

The liquid cooling scheme uses cooling liquids such as water, ethanol, and silicone oil to dissipate heat through indirect contact between the evenly distributed flow guide grooves on the liquid cooling plate and the battery cells. Its advantages include:

1) Close to the heat source for effective cooling;

2) Compared with the container air-cooling solution of the same capacity, the liquid cooling system does not need to design air ducts, and is more suitable for large-scale energy storage power stations;

3) Compared with the air-cooled system, due to the reduction of the use of mechanical components such as fans, the failure rate is lower;

4) Liquid cooling has low noise and saves system power consumption;

The core of the liquid cooling system of the energy storage battery pack thermal management cooling system is the chiller and the liquid cooling plate. Among them, the chiller includes compressors, condensers, throttles, evaporators, water pumps and other components. The liquid cooling plate is to process raw materials such as copper and aluminum into corresponding plates. The production process of the liquid cooling plate is divided into needle welding, blowing, etc. Expansion, die casting, stamping, friction stir welding, etc.

With the start of new energy power stations, off-grid energy storage and other energy storage power stations with larger battery capacity and higher system power density, the energy storage system has greater energy density and calorific value, and has higher requirements on life and service life, which will promote the industry to become more Multi-turn adopts liquid cooling solution.

 

 

3. Phase change cooling

Phase change cooling is a cooling method that utilizes the phase change of phase change materials to absorb heat. The selection of phase change materials has a greater impact on the heat dissipation effect of the battery. When the selected phase change material has a larger specific heat capacity and a higher heat transfer coefficient The higher the value, the better the cooling effect under the same conditions, otherwise the worse the cooling effect.
Phase change cooling has the advantages of compact structure, low contact thermal resistance, and good cooling effect, but the phase change material itself does not have the ability to dissipate heat, and the absorbed heat needs to be exported by the liquid cooling system and air cooling system, otherwise the phase change material cannot continue to absorb heat . In addition, phase change materials take up space and are expensive.

 

Phase change cooling

 

Produkte und Lösungen

 

ModellCNYL -45
Kühlleistung45KW
Genauigkeit der Temperaturregelung±0,5℃ Temperaturaufzeichnung in Echtzeit
Sekundäres KältemittelEthylenglykol-Frostschutzmittel, vollständig geschlossene Bauweise des Kältemittelkreislaufs
KältemittelR410A
Durchfluss300L/min~400L/min Anzeigeverlauf einstellen
Niederdruck elektrischSchneider/Siemens
Bildschirm7-Zoll-Farb-Touchscreen
Strom380V 50HZ Wählen Sie 220V60HZ 460V 60HZ
Material der SchaleKaltgewalztes Spritzblech REL7035
Interne VerrohrungSUS304

 

ModellCNYL-5CNYL-8.5
Kühlleistung5KW8,5KW
Genauigkeit±0,5℃ Temperaturaufzeichnung in Echtzeit±0,5℃ Temperaturaufzeichnung in Echtzeit
Minimale Wassereintrittstemperatur15℃(Kann je nach Batteriesystem angepasst werden)13℃(Kann je nach Batteriesystem angepasst werden)
Erkennung des SystemdrucksensorsFlüssigkeitsausgangsdruck, Flüssigkeitseintrittsdruck, Hoch- und Niederdruck des Kühlsystems
COP*2.0*2.2
KompressorHermetischer Kompressor (1 Satz)34cm3 /UmdrehungVollständig gekapselter Scrollverdichter (1 Satz)
KältemittelR410AR410A
Anzeige7-Zoll-Farb-Touchscreen7-Zoll-Farb-Touchscreen
Betriebstemperaturbereich der Umgebung-45℃~55℃
Steuerspannungsbereich18-32V18-32V
Kältetechnik Hochdruck Höchstleistung2.2KW3,5KW
Durchschnittliche elektrische Eingangsleistung der Kühlung (kW) +1,5 kWEinstellbare Frequenz +2kWeinstellbare Frequenz
COP*2.0*2.2

 

ModellCHDYL-4
Kühlleistung4KW
Genauigkeit±1℃ Temperaturaufzeichnung in Echtzeit
KompressorHermetischer Kompressor (1 Satz)
KältemittelR134A
Anzeige7-Zoll-Farb-Touchscreen
KontrollsystemPLC
KommunikationCAN
Betriebstemperaturbereich der Umgebung-45℃~55℃

 

Kühlung von Energiespeicherbatterien

Wir bieten die Entwicklung und Herstellung kompletter Temperaturkontrollsysteme an. Von Standardmodellen bis zu kompletten kundenspezifischen Produkten bis hin zu 1000 Tonnen. Wir haben uns auf den Kundenservice spezialisiert und sind bestrebt, jedem Kunden zu helfen, das optimale Temperaturkontrollsystem für seinen spezifischen Bedarf zu finden.

Wir bieten maßgeschneiderte Lösungen, die nicht dem Standard entsprechen. 

 

E-Mail: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scannen.

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Neueste Nachrichten
Angebot anfordern
Name
E-Mail-Adresse
Telefon
Unternehmen
Please fill in your requirements
展开更多
Angebot anfordern

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz