Introduction of 20 ton air cooled chiller

20 ton air cooled chiller is a type of water chiller. It cools normal temperature water to a certain temperature through the compressor of the chiller to strengthen the cooling of the mold or machine. It is used as a stand-alone machine. The heat dissipation device is a built-in fan. There are three main mutual Contact systems: refrigerant circulation system, water circulation system, electrical automatic control system.

Features of 20 ton air cooled chiller:

1. The compressor of the unit adopts a scroll-type fully sealed compressor and electronic control components, and is equipped with a condenser and evaporator made of high-quality copper tubes with high heat exchange efficiency;

2. Equipped with various safety protection devices, with stable performance, low noise, long service life and simple operation. Using LCD display human-machine interface, the operation is simple and convenient, and the operating status is clear at a glance;

3. The models adopt single compressor or multi-compressor combined refrigeration system. The compressors can automatically operate alternately according to load changes, balancing the operating hours of each compressor, thereby saving energy consumption and extending the service life of the chiller. Convenient for energy adjustment and more energy-saving under partial load;

4. The whole machine casing has a box-type structure, with beautiful appearance and compact structure. The operation of the unit can be checked at any time. The unit can be equipped with its own water tank and circulating water pump according to the cooling capacity, without the need for cooling towers and cooling water pumps, and installation and maintenance are simple and convenient.

 

20 Ton Air Cooled Chiller

 

The basic composition of 20 ton air cooled chiller:

Condenser: In the refrigeration process, the condenser plays the role of outputting heat energy and condensing the refrigerant. After the high-pressure superheated steam discharged from the refrigeration compressor enters the condenser, all the heat absorbed during the working process, including the heat absorbed from the evaporator and refrigeration compressor and in the pipeline, is transferred to the surrounding medium (water or air) taken away. The high-pressure superheated vapor of the refrigerant recondenses into a liquid. (According to different cooling media and cooling methods, condensers can be divided into three categories: water-cooled condensers, air-cooled condensers, and evaporative condensers).

Liquid receiver: The liquid receiver is installed after the condenser and is directly connected to the drain pipe of the condenser. The refrigerant liquid of the condenser should flow into the liquid receiver unobstructed, so that the cooling area of the condenser can be fully utilized. On the other hand, when the heat load of the evaporator changes, the demand for refrigerant liquid also changes. At that time, the liquid receiver plays the role of adjusting and storing refrigerant. For small chiller refrigeration equipment systems, liquid receivers are often not installed, but condensers are used to adjust and store refrigerant.

Drying filter: In the refrigeration cycle of the chiller, moisture and dirt (oil, iron filings, copper filings) must be prevented from entering. The main source of moisture is the trace moisture contained in the newly added refrigerant and lubricating oil, or due to Moisture brought by air entering during system maintenance. If the water in the system is not completely removed, when the refrigerant passes through the throttle valve (thermal expansion valve or capillary tube), the water will sometimes solidify into ice due to the drop in pressure and temperature, blocking the passage and affecting the normal operation of the refrigeration device. Therefore, a filter drier must be installed in the chiller refrigeration system.

Evaporator: The evaporator is a heat exchange device that relies on the evaporation (actually boiling) of the refrigerant liquid to absorb the heat of the cooled medium. Its function in the refrigeration system is to absorb heat (or output cooling capacity). In order to ensure that the evaporation process can proceed stably and lastingly, the evaporated gas must be continuously pumped away by a refrigeration compressor to maintain a certain evaporation pressure.

Thermal expansion valve: The thermal expansion valve is not only a flow regulating valve in the chiller refrigeration system, but also a throttle valve in the refrigeration equipment. It is installed between the drying filter and the evaporator in the refrigeration equipment. Its temperature sensing package It is wrapped at the outlet of the evaporator. Its main function is to throttle and reduce the pressure of high-pressure and normal-temperature refrigerant liquid when flowing through the thermal expansion valve, and turn it into low-temperature and low-pressure refrigerant wet vapor (mostly liquid, a small part is steam) into the evaporator, and vaporizes in the evaporator. Absorb heat to achieve the purpose of cooling.

Refrigerant: Most industrial chillers used in modern industry use R22 or R12 as refrigerant. Refrigerant is the flowing working fluid in the refrigeration system. Its main function is to carry heat and absorb and release heat when its state changes.

 

Anfrage

E-Mail: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Präzisionskältemaschinen / KleinkältemaschinenPräzisionskältemaschinen / Kleinkältemaschinen

(Benutzerdefinierte Designs)

Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.

 

Temperaturbereich -18°C ~ +30°C +5°C ~ +35°C Reihe
Kühlleistung0,35 ~ 0,9kW1,8 ~ 50kW
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden

 


 

Umwälzkühler

Rückkühler

(Benutzerdefinierte Designs)

Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.

 

Temperaturbereich Serie -25°C ~ +30°C -45°C ~ +30°C Reihe Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Kühlleistung0,8 ~ 30kW0,75 ~ 12kW0,4 ~ 6kW0,2 ~ 6kW0,3 ~ 5kW
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden

 


 

Niedertemperaturkühler

Niedertemperatur-Kühlgeräte

(Benutzerdefinierte Designs)

Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.

 

Temperaturbereich Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°CSerie -110°C ~ -50°C Serie -150°C ~ -110°C
Kühlleistung12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2,5 ~ 11kW
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden

 


 

Chillers for Automotive Test

(Benutzerdefinierte Designs)

Temperatursimulation für die Qualitätsprüfung von Fahrzeugen: Prüfung der Batterielebensdauer, Prüfstand für Einspritzdüsen/Motoren, Airbag-Prüfung, Komponentenprüfstand, usw.

 

 


 

Chillers for Semiconductor

(Benutzerdefinierte Designs)

Geeignet für die präzise Temperaturkontrolle von elektronischen Bauteilen. Bei der Herstellung von elektronischen Halbleiterkomponenten für raue Umgebungen umfassen die Phasen der IC-Gehäusemontage sowie der Entwicklungs- und Produktionstests auch elektronische Wärmetests und andere Simulationen von Umwelttests.

 


 

Kältemaschinen für die Energiespeicherung

 

Flüssigkeitskühlung für Batterie-Energiespeichersysteme

(Benutzerdefinierte Designs)

 

 

 

 

TypenFür Converting StationFür EnergiespeicherbatterieFür die Ladestation
Kühlleistung45kW5 ~ 8,5kW4kW
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden

 


 

Kühlmittelverteilerstation

 

Baureihe ZLFQ

(Benutzerdefinierte Designs)

Kühlmittelverteilereinheit

Flüssigkeitskühlgeräte eignen sich für die Prüfung von Halbleitern, die Prüfung elektronischer Geräte bei konstanter Temperatur, die Kühlung der Serverinfrastruktur und andere Orte, an denen die Temperatur von Flüssigkeiten kontrolliert wird.

 

 

 

Temperaturbereich +5°C ~ +35°C +5°C ~ +35°C
Kühlleistung15 ~ 150kW200 ~ 500kW
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden

 


 

Thermofutter

 

MD-Thermofutter-Serie

(Benutzerdefinierte Designs)

Es wird für die Prüfung von HF-Bauteilen und Leistungsbauteilen mit hoher Dichte (IGBTs und MOSFETs) verwendet und kann auch für die schnelle Kühlung von flachen Laborplatten (Plasma, biologische Produkte, Batterien) usw. eingesetzt werden.

 

 

 

Temperaturbereich -75°C ~ +225°C
Temperaturgenauigkeit±0.1℃
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden

 


Schrauben-Kühlanlagen

 

Schraubenkühler (Benutzerdefinierte Designs)

Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen

 

 

 

Temperaturbereich +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Kühlleistung107 ~ 1027kW (Einzelverdichter)299 ~ 2134kW (Doppelkompressor)98 ~ 934kW (Einzelverdichter)272 ~ 1940kW (Doppelkompressor)48 ~ 467kW (Einzelverdichter)51 ~ 497kW (Einzelverdichter)
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Angebot anfordern
Name
E-Mail-Adresse
Telefon
Unternehmen
Nachricht

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz