Air Cooled Water Chiller System
The air cooled water chiller system is widely used in the global industrial market and is a relatively efficient refrigeration equipment. Although the air cooled water chiller system is equipped with multiple protection devices, these are all to prevent direct damage to the unit in case of failure. If the enterprise wants to ensure high cooling efficiency and long service life of the equipment, it must remember to do regular maintenance and inspection. So, what aspects of an air cooled water chiller system should be checked?
1. Regularly check the compressor
The compressor is the “heart” of the air cooled water chiller system, and its quality directly affects the stability of the chiller in use. The necessary acceptance test for equipment should be carried out in accordance with the principles of air tightness test first, vacuum test second, sub-item test first, and machine test last.
2. Check the stability of voltage and current
When the air cooled water chiller system is working normally, the voltage is 380V (the voltage of DYJ-01A~DYJ-02A is 220V, and the voltage in other foreign regions is also 410V, etc.), and the current is normal within the range of 11A-15A.
3. Regularly check the instrument
The temperature control meter is out of control, replace the temperature control meter. High voltage failure, poor heat dissipation, radiator is too dirty, clean the radiator. Poor ventilation, improve ventilation conditions. The cooling fan does not work, check whether the fan motor is burnt out or short circuited, repair or replace the motor. The high-pressure engine is damaged, replace the high-pressure engine.
4. Regular cleaning
In addition to checking the technical performance of the air cooled water chiller system, care should also be taken to protect the neat appearance of the equipment and the cleanliness of the work site. After the product has been in operation for 6 months, it is necessary to clean the entire system, such as pipes, filters, condensers, fans, etc., especially the fans, like our commonly used fans, are covered with dust and affect heat dissipation, so the cooling efficiency will be directly reduced.
5. Regularly check whether the refrigerant is reduced
Judging by the high pressure and low pressure gauge values on the front of the air cooled water chiller system. When the chiller is running normally, the high pressure is 11-17kg and the low pressure is 3-5kg, which is the normal range. In the shutdown state, both high pressure and low pressure are around 0.6kg.
In addition to the above-mentioned main inspection aspects, it is also necessary to check the oil level and oil temperature of each compressor, check the main power supply voltage and current, and check whether the set value of the chilled water supply temperature is appropriate. If there is a problem, make changes in time.
Maßgeschneiderte Lösungen für Ihr Unternehmen
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperaturregelbereich: -150°C bis -5°C
Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.
Temperaturbereich | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C |
Kühlleistung | bis zu 360 kW | bis zu 360 kW | bis zu 360 kW | bis zu 270kW | bis zu 180kW |
Rückkühler (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.
Temperaturbereich | Serie -25°C ~ +30°C | -45°C ~ +30°C Reihe | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Kühlleistung | bis zu 38kW | bis zu 12kW | bis zu 7,2 kW | bis zu 7,2 kW | bis zu 8,6 kW |
Raumtemperatur-Kühlgeräte / Kleinkühlgeräte
Temperaturregelbereich: +5°C bis +50°C
Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.
Temperaturbereich | -18°C ~ +30°C | +5°C ~ +35°C Reihe |
Kühlleistung | bis zu 0,9 kW | bis zu 50kW |
Kühlgeräte mit direkter Kühlung
Temperature Control Range: -120°C to -10°C
Er eignet sich für Orte mit kleiner Wärmeaustauschfläche und großem Wärmeaustausch.
Temperaturbereich | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Leistung des Kompressors | bis zu 8HP | bis zu 8HP*2 | bis zu 45HP*3 |
Direktkühlende Ultra-Niedrigtemperatur-Kühlgeräte
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperaturbereich | -150°C ~ -110°C |
Kühlleistung | bis zu 11kW |
Schraubenkühler
Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen
Customized solutions for your business.
Temperaturbereich | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Kühlleistung | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |