Suche Alle suchen

Cooling System in Data Center

KlassifizierungIndustrie-Nachrichten 180 0

Cooling System in Data Center

Kontaktieren Sie uns noch heute für die perfekte Lösung zur Temperaturkontrolle

 

With the rapid development of Internet technology, the scale and number of data centers are also expanding. During the operation of the data center computer room, a stable and reliable refrigeration system is essential.

Classification of data center computer room refrigeration systems

Data center computer room refrigeration systems are mainly divided into two categories: air cooling and water cooling.

1. Air-cooled refrigeration system

Air-cooled refrigeration systems are the most common refrigeration method. They mainly use fans to extract hot air from the server room, and exhaust the heat to the outside through air conditioners or cooling towers.

The air-cooled refrigeration system is mainly composed of four parts: fan, condenser, evaporator and control system. The fan is responsible for extracting hot air from the server room; the condenser condenses the moisture in the hot air into liquid and releases a large amount of heat; the evaporator absorbs the moisture in the hot air from the condenser and takes away the heat at the same time; the control system Responsible for adjusting the fan speed to maintain a constant cooling effect.

The air-cooled refrigeration system has the advantages of simple equipment, easy maintenance, and relatively low cost. However, its energy efficiency ratio is relatively low and requires more electricity to maintain the cooling effect.

2. Water cooling refrigeration system

The water-cooled refrigeration system uses the heat of water to take away the heat of the server by directly contacting the server. Water cooling systems can be divided into two types: natural cooling and forced cooling. Natural cooling uses low-temperature water provided by the natural environment for cooling; forced cooling uses a refrigerator to cool the water below the ambient temperature, and then sends the cooled water to the server through a water pump for cooling. The advantage of the water cooling system is that it has higher energy efficiency under the same cooling effect, but the equipment is complex and the maintenance cost is high.

 

Cooling System in Data Center

 

The future development trend of cooling system in data center

As energy prices rise and environmental protection requirements increase, the refrigeration system of data center computer rooms is developing in a more efficient and energy-saving direction. Future data center room cooling systems may be more inclined to use natural cooling or hybrid cooling to reduce dependence on power resources and reduce carbon emissions. At the same time, with the development of AI and big data technology, the cooling system of the data center computer room may also become more intelligent, able to automatically adjust the cooling effect and improve cooling efficiency. In addition, with the development of new materials, future data center room refrigeration systems may use more efficient heat dissipation materials to improve energy efficiency.

The cooling system of the data center computer room is an important factor in ensuring the stable operation of the data center. Whether air-cooled or water-cooled, each has its own unique advantages and disadvantages. In the future, we expect to see the emergence of more efficient, energy-saving, and smarter refrigeration systems to meet the growing cooling needs of data centers.

 

ModellZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
Temperaturbereich +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
Kühlwasser5℃~30℃ Einsatz eines Siemens/Honeywell-Regelventils zur Steuerung des Kühlwasserflusses
Genauigkeit der Temperaturregelung±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
Flusskontrolle10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
Die Durchflussregelung wird über einen Frequenzumrichter eingestellt, die Genauigkeit beträgt ±0,3 l/min.
Kühlleistung (MAX)15kW25kW50kW75kW100kW150kW
Speichervolumen15L30L60L100L150L200L
SoleWasser, Silikonöl, fluorierte Flüssigkeit, wässrige Ethylenglykol-Lösung, usw.
Mittlere RohrleitungSUS304SUS304SUS304SUS304SUS304SUS304
Größe der Eingangs- und AusgangsschnittstelleG3/4G1G1DN32DN40DN50
Schnittstelle zum KühlwasserG3/4G1DN40DN50DN50DN65
Kühlwasserdurchfluss 7~20℃2.5m³/h4m³/h8m³/h13m³/h17m³/h25m³/h
380V 50HZ 1kW1,5 kW3kW4kW5kW6kW
ShellKaltgewalztes Blech Spray RAL7035

 

ModellZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
Temperaturbereich +5℃~35℃
Temperaturgenauigkeit±0.5℃
Durchflusskontrolle15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
Kühlleistung(MAX) 200kW250kW300kW400kW500kW
Speichervolumen250L300L600L1000L1200L
MittelWasser, Silikonöl, fluorierte Flüssigkeit, wässrige Ethylenglykol-Lösung, usw.
Mittlere RohrleitungSUS304
Größe der Eingangs- und AusgangsschnittstelleDN65DN65DN65DN80DN80
Schnittstelle zum KühlwasserDN80DN80DN100DN100DN125
Kühlwasserdurchfluss 7~20℃34m³/h43m³/h51m³/h69m³/h86m³/h
Stromversorgung 380V 50HZ7kW7kW8kW9kW13kW
ShellKaltgewalztes Blech Spray RAL7035

 

Kälteverteilereinheit

 

Wir bieten die Entwicklung und Herstellung kompletter Temperaturkontrollsysteme an. Von Standardmodellen bis zu kompletten kundenspezifischen Produkten bis hin zu 1000 Tonnen. Wir haben uns auf den Kundenservice spezialisiert und sind bestrebt, jedem Kunden zu helfen, das optimale Temperaturkontrollsystem für seinen spezifischen Bedarf zu finden.

Wir bieten maßgeschneiderte Lösungen, die nicht dem Standard entsprechen. 

 

E-Mail: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scannen.

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Neueste Nachrichten
Angebot anfordern
Name
E-Mail-Adresse
Telefon
Unternehmen
Nachricht

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz