Suche Alle suchen

Evaporative Heating and Cooling Machine

KlassifizierungIndustrie-Nachrichten 231

Evaporative Heating and Cooling Machine

 

The evaporative heating and cooling machine is used in many industries and laboratories. This equipment is actually similar to the previous mold temperature machine and constant temperature bath. Then, compared with these two, why is the evaporative heating and cooling machine more popular? ?

1. Setting of internal program of evaporative heating and cooling machine

Adopt feed-in PID, model-free self-construction tree algorithm, PLC controller, material temperature control and equipment outlet temperature control mode can be freely selected, and the temperature difference between equipment outlet temperature and reaction material temperature can be controlled and set. For example, SUNDI-320 series can program 5 Each program can be programmed with 40 steps. The evaporative heating and cooling machine’s inlet temperature, equipment outlet temperature, and reactor material temperature (external temperature sensor) can be fed back at three points.

2. Explosion-proof customization of the size of the evaporative heating and cooling machine

The size of the evaporative heating and cooling machine is different, and the size, isolation and explosion-proof and various optional functions can be customized according to user requirements. Generally speaking, the size of each model of equipment is different, and users can put forward their own size requirements and customize them when communicating.

3. Refrigeration system of evaporative heating and cooling machine

The equipment adopts compressor refrigeration (single-unit self-cascading refrigeration technology). The whole system is a fully enclosed system. There will be no oil mist at high temperature and no moisture in the air at low temperature. The system will not increase the pressure due to high temperature during operation. Low temperature automatic replenishment of heat transfer medium.

4. Protection function of evaporative heating and cooling machine

The equipment has self-diagnosis function; refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other reliable protection functions. If an abnormality occurs during the operation of the equipment, the protection function can be turned on in time.

The evaporative heating and cooling machine has certain advantages in the pharmaceutical and chemical industry. The isolation, explosion-proof and protection functions can make the operation of the equipment more reliable.

 

Maßgeschneiderte Lösungen für Ihr Unternehmen


Kühl- und Heizsysteme (Serie SUNDI)

Temperaturregelbereich: -120°C bis +350°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Automobilindustrie, Halbleiter- und Elektrotests, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -40 ~ +200°C Serie -10 ~ +200°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C -25 ~ +200°C eine Maschine für zwei Reaktoren -40 ~ +200°C eine Maschine für zwei Reaktoren
Kühlleistungbis zu 3kWbis zu 15kWbis zu 200kWbis zu 200kWbis zu 200kWbis zu 25kWbis zu 60kWbis zu 25kWbis zu 15kWbis zu 80kWbis zu 80kWbis zu 80kWbis zu 10*2kWbis zu 10*2kW

 


Kühl- und Heizsysteme (WTD-Serie)

(Mikrokanal / Röhrenreaktoren spezialisiert)

Temperaturregelbereich: -70°C bis +300°C

Spezielles Design für Mikrokanäle (geringe Flüssigkeitsspeicherkapazität, starke Wärmeaustauschkapazität, Zirkulationssystem mit hohem Druckabfall)

 

Temperaturbereich -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Kühlleistungbis zu 7,5 kWbis zu 5,5 kWbis zu 50kW

 


Kühl- und Heizsysteme (TES-Serie)

Temperaturregelbereich: -85°C ~ +250°C

Temperaturregelungsgenauigkeit: ± 0,3°C

 

 

Temperaturbereich Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Kühlleistungbis zu 25kWbis zu 25kWbis zu 60kW

 


Kühl- und Heizmaschinen (LTS-Serie)

Temperaturregelbereich: -80°C bis +80°C

Es wird häufig in der Halbleiterindustrie eingesetzt, um die Temperatur der Reaktionskammer, der Heizplatte und des nicht brennbaren Wärmeträgers zu regeln.

 

 

Temperaturbereich -20°C ~ +80°C Reihe Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Durchflusskontrolle7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Umwälzpumpen für Kühlung und Heizung

Temperaturregelbereich: -45°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Kühlleistungbis zu 15kWbis zu 15kW

 


Heizungsumwälzpumpen

Temperaturregelbereich: +50°C bis +300°C

Hinweis: Die UC-Serie kann die Temperatur des Wärmeträgermediums regeln. Die UST-Serie kann nicht nur die Temperatur des Wärmeträgermediums, sondern auch die Temperatur des Reaktionsmaterials regeln.

Temperaturbereich +50°C ~ +200°C (UC-Serie) +50°C ~ +300°C (UC-Serie) +50°C ~ +300°C (UST-Serie)
Heizleistungbis zu 38kWbis zu 200kWbis zu 95 kW

 


TCU Multireaktoren Temperaturkontrollsystem

Temperaturregelbereich: -120°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -45°C ~ +250°C -120°C ~ +250°C ReiheKundenspezifisches TemperaturkontrollsystemRT+10°C ~ +135°C
Heizleistungbis zu 80kWbis zu 80kWBenutzerdefiniertbis zu 300kW

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Neueste Nachrichten

购物车

X

我的足迹

X