Heater and cooler unit is widely used in pharmaceutical, chemical, biological, laboratory, new energy, components and other industries to provide temperature control equipment for cold source and heat source. So, how much do you know about this kind of equipment?

First, the working principle of the heater and cooler unit:

1. The heater and cooler unit can achieve the purpose of refrigeration, heating, constant temperature and separation in various experiments such as reactors, reactors, drying equipment, mixing equipment, separation equipment, and heat transfer equipment.

2. Heater and cooler unit is an instrument and equipment with refrigeration and heating functions. Through the heat transfer medium, it goes from the oil tank to the equipment, and then returns to the oil tank from the equipment. The equipment controller can adjust the fluid temperature by controlling the fluid temperature according to the fluid temperature measured by the sensor. device temperature.

3. The heater and cooler unit uses compressors for refrigeration at high temperatures, which is often referred to as stand-alone self-cascading refrigeration technology, which can eliminate the need to replace the heat transfer medium when performing exothermic reactions at high temperatures, and utilizes compressor refrigeration technology to bring Take off excess heat.

4. The heater and cooler unit adopts refrigeration and heating dynamic temperature control technology, which can transmit the temperature of the liquid inlet and outlet and the material in real time, and control the heat absorption and release when the temperature difference is large, and use the heat transfer medium to control the temperature.

5. The heater and cooler unit adopts a fully enclosed pipeline design, uses a plate heat exchanger, reduces the demand for heat transfer fluid, and improves the thermal energy utilization rate of the system to achieve rapid temperature increase.

Second, the characteristics of the heater and cooler unit:

1. The heater and cooler unit adopts a fully enclosed system. There will be no oil mist at high temperature, and no moisture in the air at low temperature. The system will not increase the pressure due to high temperature during operation, and automatically replenish heat transfer medium at low temperature.

2. The heater and cooler unit has a self-diagnosis function; if an abnormality occurs during the operation of the equipment, the protection function can be turned on in time.

3. The circulation pump of the heater and cooler unit outputs the heat transfer fluid to heat the materials in the supporting equipment.

4. The heater and cooler unit is equipped with an exhaust valve, which is convenient for replenishing circulating fluid into the equipment; the heater is customized and has a long service life.

5. It has over-temperature alarm function, overload and over-current protection function. The temperature control adopts PID method, and the temperature control accuracy is high.

6. A fully closed system is adopted, and the heat transfer fluid circulation system is sealed to prolong the service life of the heat transfer fluid.

Third, considerations for the selection of heater and cooler unit:

1. Factors such as the size, weight, and material of the reactor or reactor need to be considered;

2. Consider the reaction temperature requirements, temperature control accuracy, jacket temperature, temperature control time, etc.;

3. The viscosity and density of the reaction medium and the corresponding medium selection;

4. Consider whether to choose air cooling or water cooling, and you can customize the isolation and explosion-proof model;

5. Consider the model size and size of the heater and cooler unit to see if the placement environment is satisfactory.

 

Maßgeschneiderte Lösungen für Ihr Unternehmen


Kühl- und Heizsysteme (Serie SUNDI)

Temperaturregelbereich: -120°C bis +350°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Automobilindustrie, Halbleiter- und Elektrotests, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -40 ~ +200°C Serie -10 ~ +200°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C -25 ~ +200°C eine Maschine für zwei Reaktoren -40 ~ +200°C eine Maschine für zwei Reaktoren
Kühlleistungbis zu 3kWbis zu 15kWbis zu 200kWbis zu 200kWbis zu 200kWbis zu 25kWbis zu 60kWbis zu 25kWbis zu 15kWbis zu 80kWbis zu 80kWbis zu 80kWbis zu 10*2kWbis zu 10*2kW

 


Kühl- und Heizsysteme (WTD-Serie)

(Mikrokanal / Röhrenreaktoren spezialisiert)

Temperaturregelbereich: -70°C bis +300°C

Spezielles Design für Mikrokanäle (geringe Flüssigkeitsspeicherkapazität, starke Wärmeaustauschkapazität, Zirkulationssystem mit hohem Druckabfall)

 

Temperaturbereich -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Kühlleistungbis zu 7,5 kWbis zu 5,5 kWbis zu 50kW

 


Kühl- und Heizsysteme (TES-Serie)

Temperaturregelbereich: -85°C ~ +250°C

Temperaturregelungsgenauigkeit: ± 0,3°C

 

 

Temperaturbereich Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Kühlleistungbis zu 25kWbis zu 25kWbis zu 60kW

 


Kühl- und Heizmaschinen (LTS-Serie)

Temperaturregelbereich: -80°C bis +80°C

Es wird häufig in der Halbleiterindustrie eingesetzt, um die Temperatur der Reaktionskammer, der Heizplatte und des nicht brennbaren Wärmeträgers zu regeln.

 

 

Temperaturbereich -20°C ~ +80°C Reihe Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Durchflusskontrolle7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Umwälzpumpen für Kühlung und Heizung

Temperaturregelbereich: -45°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Kühlleistungbis zu 15kWbis zu 15kW

 


Heizungsumwälzpumpen

Temperaturregelbereich: +50°C bis +300°C

Hinweis: Die UC-Serie kann die Temperatur des Wärmeträgermediums regeln. Die UST-Serie kann nicht nur die Temperatur des Wärmeträgermediums, sondern auch die Temperatur des Reaktionsmaterials regeln.

Temperaturbereich +50°C ~ +200°C (UC-Serie) +50°C ~ +300°C (UC-Serie) +50°C ~ +300°C (UST-Serie)
Heizleistungbis zu 38kWbis zu 200kWbis zu 95 kW

 


TCU Multireaktoren Temperaturkontrollsystem

Temperaturregelbereich: -120°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -45°C ~ +250°C -120°C ~ +250°C ReiheKundenspezifisches TemperaturkontrollsystemRT+10°C ~ +135°C
Heizleistungbis zu 80kWbis zu 80kWBenutzerdefiniertbis zu 300kW