Industrial Water Cooled Chiller Machine
It is extremely necessary for industrial water cooled chiller machine to be maintained regularly so that the equipment can operate normally. Today I will introduce you some three items that need to be checked regularly for industrial water cooled chiller machine!
1. Regularly clean the scale. If the water quality in the operating environment is poor, after the long-term operation of the industrial water cooled chiller machine, there is no effective treatment for the water source, and a large amount of scale will inevitably be generated inside the equipment. When the scale accumulates to a certain extent, it will directly affect the normal use of the pipeline. When the water flow of the water source decreases, the heat dissipation performance of the industrial water cooled chiller machine will be seriously affected, especially for large equipment. If the heat dissipation performance is poor, Then the use stability of the equipment will inevitably be affected, and even the cooling performance will continue to decline, seriously affecting the normal use of the enterprise.
2. If there is a lot of dust in the working environment of the industrial water cooled chiller machine, after a period of operation, the equipment needs to be cleaned regularly. The existence of dust threatens the stable operation of the equipment. When the dust enters the interior of the industrial water cooled chiller machine, the equipment is affected by the dust, and it is prone to serious failures such as reduced operating power, which directly threatens the normal use of the equipment. In order to maintain the stable operation of the industrial water cooled chiller machine, it is necessary for the enterprise to clean up the dust existing in the environment in a timely manner to ensure that the operating environment of the equipment is suitable for long-term stable use of the equipment, so as to be able to completely stay away from various common faults and avoid industrial water cooled chiller The machine has problems such as downtime.
3. To avoid failure of the industrial water cooled chiller machine, it is also necessary to regularly complete the treatment of water sources and the treatment of environmental dust. It can provide a comfortable working environment for industrial chillers and pay attention to maintenance. Even if the enterprise runs the industrial water cooled chiller machine for a long time, the equipment can also maintain stable operating performance and truly achieve the goal of quickly reducing the space temperature.
A large amount of dust and poor water quality in the operating environment of industrial water cooled chiller machine will affect the normal operation of the equipment, and even lead to downtime. If you want to increase the operating power, you need to conduct regular inspections to ensure the operating environment required by the equipment and effectively maintain the stable operating power of the industrial water cooled chiller machine.
Maßgeschneiderte Lösungen für Ihr Unternehmen
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperaturregelbereich: -150°C bis -5°C
Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.
Temperaturbereich | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C |
Kühlleistung | bis zu 360 kW | bis zu 360 kW | bis zu 360 kW | bis zu 270kW | bis zu 180kW |
Rückkühler (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.
Temperaturbereich | Serie -25°C ~ +30°C | -45°C ~ +30°C Reihe | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Kühlleistung | bis zu 38kW | bis zu 12kW | bis zu 7,2 kW | bis zu 7,2 kW | bis zu 8,6 kW |
Raumtemperatur-Kühlgeräte / Kleinkühlgeräte
Temperaturregelbereich: +5°C bis +50°C
Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.
Temperaturbereich | -18°C ~ +30°C | +5°C ~ +35°C Reihe |
Kühlleistung | bis zu 0,9 kW | bis zu 50kW |
Kühlgeräte mit direkter Kühlung
Temperature Control Range: -120°C to -10°C
Er eignet sich für Orte mit kleiner Wärmeaustauschfläche und großem Wärmeaustausch.
Temperaturbereich | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Leistung des Kompressors | bis zu 8HP | bis zu 8HP*2 | bis zu 45HP*3 |
Direktkühlende Ultra-Niedrigtemperatur-Kühlgeräte
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperaturbereich | -150°C ~ -110°C |
Kühlleistung | bis zu 11kW |
Schraubenkühler
Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen
Customized solutions for your business.
Temperaturbereich | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Kühlleistung | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |