Laboratory Heating and Cooling Units for Jacketed Reactors
When choosing the right heating and cooling device for your lab jacketed reactor, you need to focus on the following aspects to ensure efficient and accurate temperature control:
1. Compatibility and design: Choose a device that can perfectly interface with your jacketed reactor to ensure good heat exchange performance. The jacket layer should be designed to facilitate the circulation of heating media (such as hot water, oil or hot and cold gas).
2. Temperature control range and accuracy: According to the experimental requirements, determine the temperature range that the device needs to cover. Usually, industrial applications range from -80°C to +250°C, and the control accuracy must reach ±0.5°C or higher.
3. Heating and cooling capacity: Evaluate the capacity of the reactor, the specific heat capacity of the material, and the desired heating/cooling rate, and select heating elements and cooling capacity with corresponding power to ensure that the set temperature is quickly reached and maintained.
4. Control system: Modern PID controllers or PLC systems can achieve precise temperature control and program setting, support remote monitoring and data recording, and improve the automation level and traceability of experiments.
5. Safety measures: including over-temperature protection, pressure control, low liquid level alarm, etc., to ensure safe and worry-free experimental operation.
6. Material and corrosion resistance: Corrosion-resistant materials, such as stainless steel 316L, should be used for parts in contact with the medium to meet the needs of different chemical media.
7. Energy efficiency and sustainability: Consider the energy efficiency level of the equipment and choose energy-saving products to reduce operating costs and environmental impact.
To obtain specific product recommendations, more detailed information is required, such as budget range, specific space limitations of the laboratory, or any specific experimental requirements. Please provide this additional information and I will provide you with more specific suggestions.
Wir bieten die Entwicklung und Herstellung kompletter Temperaturkontrollsysteme an. Von Standardmodellen bis hin zu kompletten kundenspezifischen Produkten. Wir haben uns auf den Kundenservice spezialisiert und sind bestrebt, jedem Kunden zu helfen, das optimale Temperaturkontrollsystem für seinen spezifischen Bedarf zu finden.
Wir bieten maßgeschneiderte Lösungen, die nicht dem Standard entsprechen. Es sind sowohl einzelne Kühlaggregate als auch kombinierte Kühl- und Heizaggregate erhältlich.
E-Mail: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Kühl- und Heizsysteme (Serie SUNDI)
- Temperaturbereich: -120℃ ~ +350℃
- Hochpräzise, intelligente Temperaturregelung
- Kühlleistung: 0,5kW ~ 1200kW
- Vollständig geschlossenes System zur Verlängerung der Lebensdauer des Thermofluids
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Kühlleistung | 1,5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0,45 ~ 200kW | 0,9 ~ 25kW | 0,25 ~ 60kW | 0,75 ~ 25kW | 0,4 ~ 15kW | 0,3 ~ 80kW | 0,2 ~ 80kW | 0,45 ~ 80kW | ||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |
Umwälzpumpen für Kühlung und Heizung
- Temperaturbereich: -45℃ ~ +250℃
- Emerson Copeland Kompressor, zuverlässige Qualität
- Selbstdiagnosefunktion, mehrere Sicherheitsschutzvorrichtungen
- Vollständig geschlossenes System zur Verlängerung der Lebensdauer des Thermofluids
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Kühlleistung | 1 ~ 15kW | 0,25 ~ 15kW | |||||||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |
Kühl- und Heizsysteme (WTD-Serie)
- (Mikrokanal / Röhrenreaktoren spezialisiert)
- Temperaturbereich: -70℃ ~ +300℃
- Leistungsstarke Umwälzpumpe, stabilere Temperaturregelung
- Breiter Temperaturbereich zur Erfüllung der Anforderungen mehrerer Branchen
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Kühlleistung | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |
TCU Multireaktoren Temperaturkontrollsystem
- Temperaturbereich: -120℃ ~ +250℃
- Versiegelte, wiederholbare Temperaturkontrolle
- Eingebautes Thermoöl-Hilfssystem für elektrische Heizung
- Hinzufügen von Kälte- und Wärmequellen-Wärmetauschermodulen je nach Bedarf
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | Serie -45°C ~ +250°C | -120°C ~ +250°C Reihe | Kundenspezifisches Temperaturkontrollsystem | RT+10°C ~ +135°C | |||||
Heizleistung | 25 ~ 80kW | 25 ~ 80kW | Benutzerdefiniert | 25 ~ 300kW | |||||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |