Laboratory High and Low Temperature Refrigeration and Heating Circulator
Laboratory high and low temperature refrigeration and heating circulators are core equipment to ensure accurate and controllable temperature during experiments. They are suitable for chemical synthesis, materials research and other fields that have strict requirements for temperature control.
When selecting this type of equipment, you should focus on the following key features:
1. Temperature range: Confirm the minimum and maximum temperatures supported by the equipment. Conventional equipment usually covers the range of -80°C to +250°C to ensure that it meets your experimental needs.
2. Control accuracy: High-precision control is critical to experimental results, look for products that provide ±0.1°C or finer control.
3. Circulation capacity: The flow rate and pressure of the pumping system determine the heat exchange efficiency. Choose the circulation capacity that suits your reactor size and experimental rate.
4. Stability: The equipment needs to be able to maintain temperature stability without significant fluctuations during long-term operation, which is very important for the consistency of experimental results.
5. Safety functions: including over-temperature protection, pressure monitoring and leakage alarm to ensure safe operation.
6. Intelligent control: Modern circulators are often equipped with touch screens, preset program control, data recording and remote monitoring functions to improve the convenience of use and the repeatability of experiments.
7. Material and corrosion resistance: The material of internal pipes and containers should be corrosion-resistant, and SUS316 stainless steel is often used to adapt to a variety of chemical media.
8. Energy efficiency and environmental protection: Considering the energy consumption level of the equipment, choosing products with high energy efficiency will help save energy and reduce emissions.
If you need a recommendation for a specific model or have specific technical parameter requirements, please provide more detailed information and I will help you more accurately.
Wir bieten die Entwicklung und Herstellung kompletter Temperaturkontrollsysteme an. Von Standardmodellen bis hin zu kompletten kundenspezifischen Produkten. Wir haben uns auf den Kundenservice spezialisiert und sind bestrebt, jedem Kunden zu helfen, das optimale Temperaturkontrollsystem für seinen spezifischen Bedarf zu finden.
Wir bieten maßgeschneiderte Lösungen, die nicht dem Standard entsprechen. Es sind sowohl einzelne Kühlaggregate als auch kombinierte Kühl- und Heizaggregate erhältlich.
E-Mail: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Kühl- und Heizsysteme (Serie SUNDI)
- Temperaturbereich: -120℃ ~ +350℃
- Hochpräzise, intelligente Temperaturregelung
- Kühlleistung: 0,5kW ~ 1200kW
- Vollständig geschlossenes System zur Verlängerung der Lebensdauer des Thermofluids
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Kühlleistung | 1,5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0,45 ~ 200kW | 0,9 ~ 25kW | 0,25 ~ 60kW | 0,75 ~ 25kW | 0,4 ~ 15kW | 0,3 ~ 80kW | 0,2 ~ 80kW | 0,45 ~ 80kW | ||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |
Umwälzpumpen für Kühlung und Heizung
- Temperaturbereich: -45℃ ~ +250℃
- Emerson Copeland Kompressor, zuverlässige Qualität
- Selbstdiagnosefunktion, mehrere Sicherheitsschutzvorrichtungen
- Vollständig geschlossenes System zur Verlängerung der Lebensdauer des Thermofluids
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Kühlleistung | 1 ~ 15kW | 0,25 ~ 15kW | |||||||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |
Kühl- und Heizsysteme (WTD-Serie)
- (Mikrokanal / Röhrenreaktoren spezialisiert)
- Temperaturbereich: -70℃ ~ +300℃
- Leistungsstarke Umwälzpumpe, stabilere Temperaturregelung
- Breiter Temperaturbereich zur Erfüllung der Anforderungen mehrerer Branchen
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Kühlleistung | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |
TCU Multireaktoren Temperaturkontrollsystem
- Temperaturbereich: -120℃ ~ +250℃
- Versiegelte, wiederholbare Temperaturkontrolle
- Eingebautes Thermoöl-Hilfssystem für elektrische Heizung
- Hinzufügen von Kälte- und Wärmequellen-Wärmetauschermodulen je nach Bedarf
- Jedes Gerät wird mehr als 12 Stunden lang einem Belastungstest unterzogen.
Temperaturbereich | Serie -45°C ~ +250°C | -120°C ~ +250°C Reihe | Kundenspezifisches Temperaturkontrollsystem | RT+10°C ~ +135°C | |||||
Heizleistung | 25 ~ 80kW | 25 ~ 80kW | Benutzerdefiniert | 25 ~ 300kW | |||||
Hinweis: Jeder Temperaturbereich von -150℃ ~ +350℃ und jede Kühlleistung kann angepasst werden |