Water Cooled Refrigeration System Chillers
The water cooled refrigeration system uses a water cooling system for heat dissipation, that is to say, it does not need to use a fan? In fact, this understanding is one-sided. According to our experience, the water cooled refrigeration system may also use a fan. In fact, most Most industrial water-cooled equipment must use fans to assist in heat dissipation. Why?
First of all, do you understand the cooling system of the water cooled refrigeration system?
The cooling system is a device for dissipating heat and cooling the condenser of the water cooled refrigeration system, and the system of this equipment cannot only have cooling water. Therefore, the water cooling system must rely on the cooling water tower to work normally, and the natural flow of the cooling water tower dissipates heat, even if there is The filler and water distribution device may also not be able to meet the heat dissipation requirements of the equipment. Therefore, it is necessary to use a fan to perform additional heat dissipation and cooling of the cooling water, or to speed up its heat dissipation and cooling effect.
Secondly, is the fan of the water cooled refrigeration system the same as the air cooling system of the air-cooled chiller?
The principle is the same, but the fan used in the cooling tower of the water-cooled chiller may not be as powerful as the fan of the air-cooled system of the air-cooled chiller, but in terms of operating principle, the two are almost the same , The cooling tower fan of the water cooled refrigeration system will often encounter problems, mainly as follows.
First, the air volume is small.
Like the air cooler, the small air volume is also one of the problems of the cooling tower fan in the water cooling system. There are many reasons for this. For example, the bearing failure mentioned below will also cause the small air volume, but the small air volume is often related to the motor. The transmission belt is related to whether the fan blade is deformed, whether there is too much dust on the fan blade, etc.
Second, bearing failure.
As long as there are fans, there will be bearing failures. The employees responsible for operating and maintaining the water cooled refrigeration system in the enterprise should regularly check the cooling tower fans, add lubricating oil regularly, and clean up possible foreign objects. If the bearings are found to be excessively worn Or if other problems cause bearing damage or operation problems, the relevant parts should be replaced in time, otherwise it will affect the heat dissipation and cooling effect of the cooling water of the cooling tower.
Niedertemperatur-Kühlgeräte (Benutzerdefinierte Designs)
Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.
Temperaturbereich | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C | Serie -150°C ~ -110°C |
Kühlleistung | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11kW |
Rückkühler (Benutzerdefinierte Designs)
Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.
Temperaturbereich | Serie -25°C ~ +30°C | -45°C ~ +30°C Reihe | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Kühlleistung | 0,8 ~ 30kW | 0,75 ~ 12kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW |
Raumtemperatur-Kühlgeräte / Kleinkühlgeräte (Benutzerdefinierte Designs)
Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.
Temperaturbereich | -18°C ~ +30°C | +5°C ~ +35°C Reihe |
Kühlleistung | 0,35 ~ 0,9kW | 1,8 ~ 50kW |
Chillers for Automotive Battery Test (Benutzerdefinierte Designs)
Temperatursimulation für die Qualitätsprüfung von Fahrzeugen: Prüfung der Batterielebensdauer, Prüfstand für Einspritzdüsen/Motoren, Airbag-Prüfung, Komponentenprüfstand, usw.
Temperaturbereich | -25°C ~ +100°C | -40°C ~ +100°C | 0°C ~ +100°C | -40°C ~ +135°C |
Kühlleistung | 2,8 ~ 38kW | 1,2 ~ 60kW | 1.8 ~ 60kW | 4 ~ 60kW |
Temperatur/Druck/Durchfluss können unabhängig voneinander geregelt werden.
1&2: eine Maschine für zwei Kontrollgruppen.
Temperaturbereich | -40 ~ +100℃ 1&2 | 0 ~ +100℃ 1&2 |
Kühlleistung | 1.8kW*2 ~ 60kW*2 | 1.8kW*2 ~ 60kW*2 |
Die Temperatur bleibt konstant, Druck und Durchfluss können unabhängig voneinander geregelt werden.
1&3: eine Maschine für drei Kontrollgruppen.
1&6: eine Maschine für sechs Kontrollgruppen.
Temperaturbereich | -40 ~ +100℃ 1&2 | -40 ~ +100℃ 1&3 | -40 ~ +100℃ 1&6 | -20 ~ +100℃ 1&6 | 0 ~ +100℃ 1&2 | 0 ~ +100℃ 1&3 | 0 ~ +100℃ 1&6 |
Kühlleistung | 2,5 ~ 60kW | 4 ~ 60kW | 10 ~ 60kW | 10 ~ 60kW | 7 ~ 60kW | 11 ~ 60kW | 18 ~ 60kW |
Halbleiter Kühlanlagen (TES series) (Benutzerdefinierte Designs)
Geeignet für die präzise Temperaturkontrolle von elektronischen Bauteilen. Bei der Herstellung von elektronischen Halbleiterkomponenten für raue Umgebungen umfassen die Phasen der IC-Gehäusemontage sowie der Entwicklungs- und Produktionstests auch elektronische Wärmetests und andere Simulationen von Umwelttests.
Temperaturbereich | Serie -45°C ~ +250°C | Serie -85°C ~ +200°C | Serie -60°C ~ +200°C |
Kühlleistung | 0,3 ~ 25kW | 0,25 ~ 25kW | 3 ~ 60kW |
Halbleiter Kühlanlagen (LTS series) (Benutzerdefinierte Designs)
Geeignet für die präzise Temperaturkontrolle von elektronischen Bauteilen. Bei der Herstellung von elektronischen Halbleiterkomponenten für raue Umgebungen umfassen die Phasen der IC-Gehäusemontage sowie der Entwicklungs- und Produktionstests auch elektronische Wärmetests und andere Simulationen von Umwelttests.
Temperaturbereich | -20°C ~ +80°C Reihe | Serie -45°C ~ +80°C | Serie -60°C ~ +80°C | Serie -80°C ~ +80°C |
Durchflusskontrolle | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Kältemaschinen für die Energiespeicherung(Benutzerdefinierte Designs)
Liquid Cooling Solutions For Battery Energy Storage Systems
Temperaturbereich | -45°C ~ +55°C |
Kühlleistung | 45kW |
Schraubenkühler (Benutzerdefinierte Designs)
Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen
Temperaturbereich | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Kühlleistung | 107 ~ 1027kW (Einzelverdichter) | 299 ~ 2134kW (Doppelkompressor) | 98 ~ 934kW (Einzelverdichter) | 272 ~ 1940kW (Doppelkompressor) | 48 ~ 467kW (Einzelverdichter) | 51 ~ 497kW (Einzelverdichter) |