Suche Alle suchen

Water Cooling Chiller System

KlassifizierungIndustrie-Nachrichten 335

Water Cooling Chiller System

 

The water cooling chiller system uses the shell-and-tube evaporator to exchange heat between water and the refrigerant. After the refrigerant system absorbs the heat load in the water and cools the water to produce cold water, the heat is brought to the shell-and-tube condenser by the action of the compressor. The refrigerant exchanges heat with the water, so that the water absorbs the heat and takes it out of the external cooling tower through the water pipe to dissipate it. At the beginning, the compressor sucks the low-temperature and low-pressure refrigerant gas after evaporation and refrigeration, and then compresses it into high-temperature and high-pressure gas and sends it to the condenser; After the high-pressure and high-temperature gas is cooled by the condenser, the gas is condensed into a normal-temperature and high-pressure liquid; when the normal-temperature and high-pressure liquid flows into the thermal expansion valve, it is throttled into low-temperature and low-pressure wet steam, which flows into the shell-and-tube evaporator to absorb the frozen water in the evaporator The heat lowers the water temperature; the evaporated refrigerant is sucked back into the compressor, and the cycle repeats.

The operation of the water cooling chiller system is inseparable from the water source. The better the quality of the water source, the less the range of equipment failures. Therefore, it is recommended to use high-quality water sources when using the water cooling chiller system, so as to reduce consumption and use costs, which is conducive to the long-term safe use of chillers by enterprises. The more stable the cooling performance of the water cooling chiller system is, the stricter the water source. Otherwise, various sudden failures will occur during the use of the equipment. So, what are the requirements of water cooling chiller system for water quality?

1. pH

Any water quality that is too alkaline or too acidic cannot meet the needs of industrial chillers, and even cause irreparable corrosive failures after long-term operation of industrial chillers. Therefore, when using the water cooling chiller system, high-quality water sources must be used in order to avoid a large number of equipment failures.

2. Hardness

Since the water cooling chiller system needs to use abundant water sources during operation, if the water quality is relatively hard, it will affect the operation of the chiller. Especially in the state of high-efficiency operation, it is easy to cause various scale problems inside the chiller. After the scale accumulates to a certain extent, it will affect the normal use of the chiller in the enterprise.

3. Water flow

If the water flow rate is too high or too low, it will restrict the operating efficiency of the equipment, and even lead to a decrease in the cooling performance of the chiller. Being able to continuously increase the water flow within a reasonable range can increase the safety of the operation of the chiller, and at the same time avoid problems such as affecting the operation of the chiller and causing irreparable losses due to the small water flow.

 

Maßgeschneiderte Lösungen für Ihr Unternehmen


 

Niedertemperaturkühler

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperaturregelbereich: -150°C bis -5°C

Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.

Temperaturbereich Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°C Serie -110°C ~ -50°C
Kühlleistungbis zu 360 kWbis zu 360 kWbis zu 360 kWbis zu 270kWbis zu 180kW

 


Umwälzkühler

Rückkühler (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.

Temperaturbereich Serie -25°C ~ +30°C -45°C ~ +30°C Reihe Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Kühlleistungbis zu 38kWbis zu 12kWbis zu 7,2 kWbis zu 7,2 kWbis zu 8,6 kW

 


Kaltwassersatz

Raumtemperatur-Kühlgeräte / Kleinkühlgeräte

Temperaturregelbereich: +5°C bis +50°C

Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.

Temperaturbereich -18°C ~ +30°C +5°C ~ +35°C Reihe
Kühlleistungbis zu 0,9 kWbis zu 50kW

 


Direktkühlende Maschine

 

Kühlgeräte mit direkter Kühlung

Temperature Control Range: -120°C to -10°C

Er eignet sich für Orte mit kleiner Wärmeaustauschfläche und großem Wärmeaustausch.

 

Temperaturbereich -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Leistung des Kompressorsbis zu 8HPbis zu 8HP*2bis zu 45HP*3

 


 

Direktkühlende Ultra-Niedrigtemperatur-Kühlgeräte

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperaturbereich -150°C ~ -110°C
Kühlleistungbis zu 11kW

 


Schrauben-Kühlanlagen

 

Schraubenkühler

Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen

Customized solutions for your business.

 

 

Temperaturbereich +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Kühlleistungup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Neueste Nachrichten

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz