Double-layer Glass Reactor Temperature Control Units

 

The refrigeration and heating devices in the double-layer glass reactor are key components for achieving precise temperature control. They work together to meet the strict temperature requirements of different chemical reactions. The following are the details of the application of refrigeration and heating devices in double-layer glass reactors:

Heating device

1. Design principle: Usually, electric heating rods or steam heating are used to transfer heat to the heating medium in the interlayer, such as thermal oil or heating water. After the medium is heated, the heat is evenly transferred to the reactants in the inner reactor through heat conduction to achieve heating of the reaction system.

2. Temperature control: Equipped with a precise temperature controller, it can set and automatically adjust the heating power to ensure that the reaction system is maintained within the set temperature range to meet the temperature requirements of the experiment or production process.

Refrigeration device

1. Working method: Through the circulating refrigeration system, the refrigerant (such as Freon or other environmentally friendly refrigerants) is used for refrigeration circulation. The refrigerant is compressed into high-temperature and high-pressure gas under the action of the refrigeration compressor. After condensation, throttling, evaporation and other processes, it finally absorbs the heat in the reactor interlayer in the evaporator and vaporizes, thereby achieving a cooling effect.

2. Temperature regulation: The refrigeration system is also equipped with a temperature controller, which can adjust the refrigeration capacity according to the experimental requirements to achieve precise cooling of the reaction materials or maintain a low temperature state.

 

Double-layer Glass Reactor Temperature Control Units

 

Overall advantages

Flexibility: It can have both heating and cooling functions to meet the complex requirements of temperature changes during the reaction process.

Accuracy: Through the high-precision temperature control system, the temperature can be finely adjusted to ensure the stability and repeatability of the experiment or production process.

Efficiency: Quickly respond to temperature changes, shorten the experimental preparation time and improve production efficiency.

Safety: Double protection design to prevent overheating or overpressure, ensuring safe operation.

In short, the integration of refrigeration and heating devices makes the double-layer glass reactor an ideal equipment for various chemical reactions, material synthesis, drug preparation and other research and production activities, especially in those occasions with strict requirements for temperature control.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 

1.Cooling and Heating Systems


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

2.Cooling Chillers


low temperature chiller

Low Temperature/Cryogenic Chillers (Water Cooled)

(Custom Designs)

  • Temperature range: -150℃ ~ -5℃
  • International brand compressor, high cooling efficiency
  • Secondary subcooling technology, fast cooling speed
  • Automated control and operation, efficient and energy-saving
  • Each device is load tested for more than 12 hours

Six product series

Temperature range -25°C ~ -5°C -45°C ~ -10°C -60°C ~ -10°C -80°C ~ -30°C-110°C ~ -50°C -150°C ~ -110°C
Cooling Capacity12kW…360kW6kW…180kW6kW…180kW4kW…180kW2kW…120kW2.5kW…11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


recirculating chiller

Recirculating Chiller/Refrigerated Circulator (Air Cooled)

(Custom Designs)

  • Temperature range: -120℃ ~ +30℃
  • International brand compressor, cascade refrigeration technology
  • Use ethylene glycol or a mixture of ethylene glycol and water
  • Fully sealed design to ensure the purity of the medium
  • Each device is load tested for more than 12 hours

Five product series

Temperature range -25°C ~ +30°C -45°C ~ +30°C -60°C ~ -20°C -80°C ~ -20°C -120°C ~ -70°C
Cooling Capacity0.8kW…30kW0.75kW…12kW0.4kW…6kW0.2kW…6kW0.3kW…5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


 

Precision Chillers / Small ChillersSmall Chillers / Mini Chillers

(Custom Designs)

  • Temperature range: -18℃ ~ +35℃
  • International brand compressor, stable performance
  • Microcomputer controller, adjustment unit 0.1℃
  • Energy saving, high temperature control accuracy
  • Each device is load tested for more than 12 hours

Two product series

Temperature range -18°C ~ +30°C +5°C ~ +35°C
Cooling Capacity0.35 ~ 0.9kW1.8kW…50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

  • Temperature range: -100℃ ~ +80℃
  • International brand compressors and other accessories
  • Fully sealed design to ensure the purity of the medium
  • PLC programmable controller
  • Each device is load tested for more than 12 hours

Five product series

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6kW…40kW2kW…15kW1kW…8kW0.kW…3kW1.5kW…3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller