Double-layer Glass Reactor Temperature Control Units
The refrigeration and heating devices in the double-layer glass reactor are key components for achieving precise temperature control. They work together to meet the strict temperature requirements of different chemical reactions. The following are the details of the application of refrigeration and heating devices in double-layer glass reactors:
Heating device
1. Design principle: Usually, electric heating rods or steam heating are used to transfer heat to the heating medium in the interlayer, such as thermal oil or heating water. After the medium is heated, the heat is evenly transferred to the reactants in the inner reactor through heat conduction to achieve heating of the reaction system.
2. Temperature control: Equipped with a precise temperature controller, it can set and automatically adjust the heating power to ensure that the reaction system is maintained within the set temperature range to meet the temperature requirements of the experiment or production process.
Refrigeration device
1. Working method: Through the circulating refrigeration system, the refrigerant (such as Freon or other environmentally friendly refrigerants) is used for refrigeration circulation. The refrigerant is compressed into high-temperature and high-pressure gas under the action of the refrigeration compressor. After condensation, throttling, evaporation and other processes, it finally absorbs the heat in the reactor interlayer in the evaporator and vaporizes, thereby achieving a cooling effect.
2. Temperature regulation: The refrigeration system is also equipped with a temperature controller, which can adjust the refrigeration capacity according to the experimental requirements to achieve precise cooling of the reaction materials or maintain a low temperature state.
Overall advantages
Flexibility: It can have both heating and cooling functions to meet the complex requirements of temperature changes during the reaction process.
Accuracy: Through the high-precision temperature control system, the temperature can be finely adjusted to ensure the stability and repeatability of the experiment or production process.
Efficiency: Quickly respond to temperature changes, shorten the experimental preparation time and improve production efficiency.
Safety: Double protection design to prevent overheating or overpressure, ensuring safe operation.
In short, the integration of refrigeration and heating devices makes the double-layer glass reactor an ideal equipment for various chemical reactions, material synthesis, drug preparation and other research and production activities, especially in those occasions with strict requirements for temperature control.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Temperature range: -150℃ ~ -5℃
- International brand compressor, high cooling efficiency
- Secondary subcooling technology, fast cooling speed
- Automated control and operation, efficient and energy-saving
- Each device is load tested for more than 12 hours
Six product series
Temperature range | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Cooling Capacity | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Temperature range: -120℃ ~ +30℃
- International brand compressor, cascade refrigeration technology
- Use ethylene glycol or a mixture of ethylene glycol and water
- Fully sealed design to ensure the purity of the medium
- Each device is load tested for more than 12 hours
Five product series
Temperature range | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Cooling Capacity | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Small Chillers / Mini Chillers
- Temperature range: -18℃ ~ +35℃
- International brand compressor, stable performance
- Microcomputer controller, adjustment unit 0.1℃
- Energy saving, high temperature control accuracy
- Each device is load tested for more than 12 hours
Two product series
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8kW…50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
- Temperature range: -100℃ ~ +80℃
- International brand compressors and other accessories
- Fully sealed design to ensure the purity of the medium
- PLC programmable controller
- Each device is load tested for more than 12 hours
Five product series
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |