Heating and Cooling Devices for Jacketed Reactors
The application of heating and cooling devices in jacketed reactors is a key component for achieving efficient and controllable chemical reaction processes. In the design of jacketed reactors, there is a cavity between its outer wall and the internal reaction chamber, which is the jacket layer. Through this jacket layer, heating media (such as hot water, steam) or cooling media (such as cold water, freezing liquid) can flow to heat or cool the materials in the reactor to achieve precise temperature control. The following are several key points for the application of heating and cooling devices in jacketed reactors:
1. Heating device:
Steam heating: often connected to the steam pipeline, using saturated steam or superheated steam as the heating source, suitable for reactions that require rapid heating and high temperature requirements.
Electric heating: heat is provided by electric heating elements installed in the jacket, such as electric heating wires or far-infrared heaters, which is suitable for scenarios with high temperature control requirements and low heating power.
Hot water circulation: using a hot water circulation system, driving hot water to circulate in the jacket through a pump, suitable for reactions that require gentle heating.
2. Cooling device:
Cold water circulation: Through the cold water circulation system, cooling water is introduced into the jacket for circulation to take away the reaction heat. It is suitable for situations where rapid cooling or low temperature reaction conditions are required.
Refrigeration liquid circulation: When a lower cooling temperature is required, the refrigerated liquid after refrigeration by the freezer can be circulated to achieve the purpose of deep cooling.
Semiconductor refrigeration: For small-scale applications or applications with extremely high temperature control accuracy, a semiconductor temperature control system may be directly attached to the surface of the reactor to achieve precise temperature control.
Temperature control: In order to accurately control the internal temperature of the reactor, an automatic control system is usually equipped, which combines a temperature sensor to monitor the temperature of the reaction medium in real time and automatically adjusts the flow and temperature of the heating or cooling medium to maintain the set temperature point. PID controller is one of the most commonly used temperature control strategies.
Safety measures: The heating and cooling systems are also equipped with safety devices, such as over-temperature protection, pressure relief valve, low liquid level alarm, etc., to ensure the safety of the operation process.
Through the integrated application of the above devices and technologies, the jacketed reactor can effectively cope with the strict requirements for temperature control in various chemical reactions, ensuring reaction efficiency and product quality.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
Ofrecemos soluciones personalizadas no estándar. Disponemos tanto de enfriadoras individuales como de unidades combinadas de refrigeración y calefacción.
Correo electrónico: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Sistemas de refrigeración y calefacción (serie SUNDI)
- Rango de temperatura: -120℃ ~ +350℃
- Control inteligente de la temperatura de alta precisión
- Capacidad de refrigeración: 0,5 kW ~ 1200 kW
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | ||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Circuladores de refrigeración y calefacción
- Rango de temperatura: -45℃ ~ +250℃
- Compresor Emerson Copeland, calidad fiable
- Función de autodiagnóstico, múltiples dispositivos de protección de seguridad
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Sistemas de refrigeración y calefacción (serie WTD)
- (Microcanales / reactores tubulares especializados)
- Rango de temperatura: -70℃ ~ +300℃
- Bomba de circulación de alto rendimiento, efecto de control de temperatura más estable
- Amplia gama de temperaturas para satisfacer las necesidades de más industrias
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW | ||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
TCU Sistema de control de temperatura multirreactores
- Rango de temperatura: -120℃ ~ +250℃
- Control de temperatura hermético y repetible
- Sistema auxiliar de aceite térmico de calefacción eléctrica incorporado
- Añade módulos de intercambio de calor por fuente de frío y calor en función de las necesidades
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C | |||||
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW | |||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Rango de temperatura: -150℃ ~ -5℃
- Compresor de marca internacional, alta eficiencia de refrigeración
- Tecnología de subenfriamiento secundario, velocidad de enfriamiento rápida
- Control y funcionamiento automatizados, eficientes y ahorradores de energía
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Six product series
Temperatura | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Capacidad de refrigeración | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Rango de temperatura: -120℃ ~ +30℃
- Compresor de marca internacional, tecnología de refrigeración en cascada
- Utilice etilenglicol o una mezcla de etilenglicol y agua
- Diseño totalmente sellado para garantizar la pureza del medio
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Capacidad de refrigeración | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Small Chillers / Mini Chillers
- Rango de temperatura: -18℃ ~ +35℃
- Compresor de marca internacional, rendimiento estable
- Controlador de microordenador, unidad de ajuste 0.1℃
- Ahorro de energía, alta precisión de control de la temperatura
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Two product series
Temperatura | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1.8kW…50kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Refrigeradores de alta temperatura
- Rango de temperatura: -100℃ ~ +80℃
- Compresores y otros accesorios de marcas internacionales
- Diseño totalmente sellado para garantizar la pureza del medio
- Controlador programable PLC
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Capacidad de refrigeración | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |