Industry Water Chiller
The industry water chiller is a device used for refrigeration. It can reduce water and other liquid cooling media to a low-temperature state so that it can be used in industrial manufacturing, building air conditioning and other fields.
Industry water chiller usually consists of compressor, condenser, evaporator, expansion valve and other main components, and is widely used in various industrial fields, such as plastic injection molding, substrate manufacturing, chemical products, pharmaceutical storage, semiconductor research, etc.
Industry water chiller is a refrigeration equipment that uses the refrigerant circulation process to cool down cooling water or other liquid substances.
The main principles of industry water chiller are as follows:
1. Cycle working principle: The main working principle of the industrial water chiller is to use the heat exchange effect between the refrigerant and water or other liquid substances to reduce the temperature of the cooling water or other liquids.
The main components responsible for circulating refrigerant consist of a compressor, condenser, dryer, regulating valve and evaporator.
2. Circulation flow direction of refrigerant: The compressor is used to compress and heat the refrigerant, and then the refrigerant is cooled through the condenser and then enters the expansion valve to regulate the valve.
The refrigerant becomes evaporated due to expansion here, and completes the process of absorbing heat in the evaporator. The heat-absorbing refrigerant flows back to the compressor, and the cycle begins again.
3. Heat exchange principle: The industry water chiller cools down through heat exchange between liquids. The liquid that needs to be cooled is introduced through the water pump, and heat is exchanged with the refrigerant through the evaporator, so that the liquid is cooled and discharged.
Accordingly, different types of industry water chillers have subtle differences, including compressor models, control systems, heat dissipation methods, etc., but their basic principles are to use heat exchange between the refrigerant and the substance to be cooled for cooling.
Specifically, the functions of industry water chiller include:
1. Provide cooling for the processing process: industry water chiller can improve production efficiency and quality by cooling the processing materials or equipment surface, which is necessary in many industrial manufacturing processes.
For example, it has applications in plastic screen printing machines, injection molding machines, electronic chip cooling, etc.
1. Provide cold water for air conditioning systems: Industry water chillers are the main components of air conditioning and central air conditioning systems in large commercial and office spaces. They transmit cooling effects through air or water to reduce the air temperature, thereby providing cold air to buildings. Keep indoor temperatures comfortable.
2. Provide cooling for mechanical equipment: In some mechanical equipment that require cooling, such as heaters, electrical control cabinets, frequency converters, motors, etc., they all need to be cooled by cooling water.
The industry water chiller can provide cooling water source for these equipment and keep the temperature of the equipment stable.
3. Help control humidity: Some specific applications need to control the humidity of the air. For example, in the printing and textile industries, the chiller can control the indoor humidity by providing cold water.
The industrial water chiller is a device used for refrigeration. Its main function is to cool down water or other liquid substances, so it can be used in industrial manufacturing, building air conditioning and other fields.
Correo electrónico: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Enfriadoras de precisión / Enfriadoras pequeñas
El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.
Temperatura | -18°C ~ +30°C | Serie +5°C ~ +35°C |
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1,8 ~ 50 kW |
Enfriadoras de recirculación
Nuestro enfriador de recirculación adopta tecnología de refrigeración de baja temperatura, la temperatura es tan baja como -120℃, y varios accesorios son personalizables.
Temperatura | Serie -25°C ~ +30°C | Serie -45°C ~ +30°C | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Capacidad de refrigeración | 0,8 ~ 30 kW | 0,75 ~ 12 kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW |
Refrigeradores de baja temperatura
Estamos especializados en la producción de refrigeradores de baja temperatura con un rango de control de temperatura de hasta -150°C, que pueden satisfacer las necesidades de refrigeración de diferentes industrias.
Temperatura | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C | Serie -150°C ~ -110°C |
Capacidad de refrigeración | 12 ~ 360 kW | 6 ~ 180 kW | 6 ~ 180 kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11 kW |
Enfriadoras para pruebas en automoción
Simulación de temperatura para pruebas de calidad de vehículos: prueba de duración de baterías, banco de pruebas de inyectores/motores de combustible, prueba de airbags, banco de pruebas de componentes, etc.
Enfriadoras para semiconductores
Adecuado para el control preciso de la temperatura de los componentes electrónicos. En la fabricación de componentes electrónicos semiconductores para entornos adversos, las fases de ensamblaje de embalajes de CI y de pruebas de ingeniería y producción incluyen pruebas térmicas electrónicas y otras simulaciones de pruebas ambientales.
Refrigeración líquida para sistemas de almacenamiento de energía en baterías
Tipos | Para estación de conversión | Para batería de almacenamiento de energía | Para estación de carga |
Capacidad de refrigeración | 45 kW | 5 ~ 8,5 kW | 4kW |
Serie ZLFQ
Unidad de distribución de refrigerante
El equipo de refrigeración líquida es adecuado para pruebas de semiconductores, pruebas de temperatura constante de equipos electrónicos, infraestructura de soporte de servidores de refrigeración y otros lugares de control de temperatura de fluidos.
Temperatura | +5°C ~ +35°C | +5°C ~ +35°C |
Capacidad de refrigeración | 15 ~ 150 kW | 200 ~ 500 kW |
Serie de mandriles térmicos MD
Se utiliza para probar dispositivos de radiofrecuencia y dispositivos de potencia de alta densidad (IGBT y MOSFET), y también puede utilizarse para el enfriamiento rápido de paneles planos de laboratorio (plasma, productos biológicos, baterías), etc.
Temperatura | -75°C ~ +225°C |
Precisión de la temperatura | ±0.1℃ |
Refrigeradores de tornillo (Diseños a medida)
Refrigeradores de tornillo de baja temperatura y refrigeradores de tornillo a temperatura ambiente
Temperatura | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacidad de refrigeración | 107 ~ 1027 kW (compresor único) | 299 ~ 2134 kW (compresor doble) | 98 ~ 934 kW (compresor único) | 272 ~ 1940 kW (compresor doble) | 48 ~ 467 kW (un compresor) | 51 ~ 497 kW (compresor único) |