With the rapid development of Internet technology, the scale and number of data centers are also expanding. During the operation of the data center computer room, a stable and reliable refrigeration system is essential.

Classification of data center computer room refrigeration systems

Data center computer room refrigeration systems are mainly divided into two categories: air cooling and water cooling.

1. Air-cooled refrigeration system

Air-cooled refrigeration systems are the most common refrigeration method. They mainly use fans to extract hot air from the server room, and exhaust the heat to the outside through air conditioners or cooling towers.

The air-cooled refrigeration system is mainly composed of four parts: fan, condenser, evaporator and control system. The fan is responsible for extracting hot air from the server room; the condenser condenses the moisture in the hot air into liquid and releases a large amount of heat; the evaporator absorbs the moisture in the hot air from the condenser and takes away the heat at the same time; the control system Responsible for adjusting the fan speed to maintain a constant cooling effect.

The air-cooled refrigeration system has the advantages of simple equipment, easy maintenance, and relatively low cost. However, its energy efficiency ratio is relatively low and requires more electricity to maintain the cooling effect.

2. Water cooling refrigeration system

The water-cooled refrigeration system uses the heat of water to take away the heat of the server by directly contacting the server. Water cooling systems can be divided into two types: natural cooling and forced cooling. Natural cooling uses low-temperature water provided by the natural environment for cooling; forced cooling uses a refrigerator to cool the water below the ambient temperature, and then sends the cooled water to the server through a water pump for cooling. The advantage of the water cooling system is that it has higher energy efficiency under the same cooling effect, but the equipment is complex and the maintenance cost is high.

 

Cooling System in Data Center

 

The future development trend of cooling system in data center

As energy prices rise and environmental protection requirements increase, the refrigeration system of data center computer rooms is developing in a more efficient and energy-saving direction. Future data center room cooling systems may be more inclined to use natural cooling or hybrid cooling to reduce dependence on power resources and reduce carbon emissions. At the same time, with the development of AI and big data technology, the cooling system of the data center computer room may also become more intelligent, able to automatically adjust the cooling effect and improve cooling efficiency. In addition, with the development of new materials, future data center room refrigeration systems may use more efficient heat dissipation materials to improve energy efficiency.

The cooling system of the data center computer room is an important factor in ensuring the stable operation of the data center. Whether air-cooled or water-cooled, each has its own unique advantages and disadvantages. In the future, we expect to see the emergence of more efficient, energy-saving, and smarter refrigeration systems to meet the growing cooling needs of data centers.

 

ModeloZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
Rango de temperatura +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
Agua de refrigeración5℃~30℃ Adopta válvula reguladora Siemens/Honeywell para controlar el flujo de agua de refrigeración.
Precisión del control de temperatura±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
control de flujo10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
El control de caudal se ajusta mediante un convertidor de frecuencia, la precisión es de ±0,3 L/min.
Capacidad de refrigeración (MAX)15 kW25 kW50 kW75 kW100 kW150 kW
Volumen de almacenamiento15L30L60L100L150L200L
SalmueraAgua, aceite de silicona, líquido fluorado, solución acuosa de etilenglicol, etc.
Canalización mediaSUS304SUS304SUS304SUS304SUS304SUS304
Tamaño de la interfaz de entrada y salidaG3/4G1G1DN32DN40DN50
Interfaz de agua de refrigeraciónG3/4G1DN40DN50DN50DN65
Caudal de agua de refrigeración 7~20℃2,5 m³/h4 m³/h8m³/h13 m³/h17 m³/h25 m³/h
380V 50HZ 1kW1,5 kW3kW4kW5kW6kW
conchaChapa laminada en frío pulverizada RAL7035

 

ModeloZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
Rango de temperatura +5℃~35℃
Precisión de la temperatura±0.5℃
Control del caudal15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
Capacidad de refrigeración(MAX) 200 kW250 kW300 kW400 kW500 kW
Volumen de almacenamiento250L300L600L1000L1200L
MedioAgua, aceite de silicona, líquido fluorado, solución acuosa de etilenglicol, etc.
Canalización mediaSUS304
Tamaño de la interfaz de entrada y salidaDN65DN65DN65DN80DN80
Interfaz de agua de refrigeraciónDN80DN80DN100DN100DN125
Caudal de agua de refrigeración 7~20℃34 m³/h43 m³/h51 m³/h69 m³/h86 m³/h
Alimentación 380V 50HZ7kW7kW8kW9kW13kW
conchaChapa laminada en frío pulverizada RAL7035

 

unidad de distribución de frío

 

Ofrecemos diseño y fabricación de sistemas completos de control de temperatura. Desde modelos estándar hasta productos personalizados completos hasta 1000 toneladas. Nos especializamos en el servicio al cliente y nos dedicamos a ayudar a cada cliente a tener el sistema de control de temperatura óptimo para su necesidad específica.

Ofrecemos soluciones personalizadas no estándar. 

 

Correo electrónico: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

escanear

La información sobre derechos de autor pertenece a lneya-online.com, por favor contacte por correo electrónico para más detalles: lilia@lneya.com

O escanee el código QR de WhatsApp o WeChat que aparece a continuación para ponerse en contacto con nosotros. 

WhatsAPP WeChat

escanear

Anterior: Siguiente:
Últimas noticias
Solicitar presupuesto
Nombre
Dirección de correo electrónico
Teléfono
Empresa
Mensaje

购物车

X

我的足迹

X
palabras clave:Alegría embotellada enfriador de agua