Glycol Chilled Water System
For low-temperature chillers using ethylene glycol solution, we call it glycol chilled water system. Its outlet water temperature is generally set below -10°C, and the specific temperature requirements are subject to user needs. Glycol chilled water systems are common in chemical plants. In order to ensure the safe and stable operation of the units, many chemical plants will strictly require explosion-proof measures for the chillers, which is what we often call explosion-proof chillers.
The structural components of low-temperature chillers are roughly the same, consisting of compressors, evaporators, condensers, throttling components, and electronic control systems. However, for glycol chilled water systems, they use low-temperature compressors and are equipped with economical separators. There are still some differences among other parts.
Working principle of glycol chilled water system
1. Compression
In order to keep the pressure in the evaporator low enough to ensure that the refrigerant is boiling at a low enough temperature, a compressor is used to pump away the evaporated refrigerant gas, that is, to compress the low-temperature and low-pressure refrigerant vapor into high-temperature and high-pressure gas. Refrigerant gas. When the suction speed of the compressor is greater than the evaporation speed of the refrigerant, the evaporation pressure will decrease and the evaporation temperature will also decrease; conversely, if the suction speed of the compressor is less than the refrigerant’s evaporation speed, the evaporation temperature and pressure will rise accordingly. High, when the compressor suction speed is equal to the refrigerant evaporation speed, equilibrium is established.
2. Condensation
The high-temperature and high-pressure refrigerant is condensed into liquid in the condenser. In the condenser, the refrigerant releases heat to air or water that is lower than its temperature. This part of the heat includes the heat absorbed by the refrigerant when it evaporates in the evaporator and the heat converted into it when the compressor compresses it.
Special attention: the temperature of the air or water must be lower than the temperature of the refrigerant, otherwise the refrigerant cannot release heat, that is, the temperature of the cooling medium is lower than the temperature of the refrigerant gas at the compressor outlet.
3. Throttling
Through the throttle, the pressure of the refrigerant is reduced from the condensing pressure to the evaporating pressure. The liquid coming out of the condenser is stored in the liquid receiver. At this time, the refrigerant is at normal temperature and high pressure. After passing through the expansion valve, the boiling point is lowered due to the pressure drop. After the liquid enters the evaporator, it easily absorbs heat and evaporates.
4. Evaporation
The low-temperature and low-pressure refrigerant liquid passing through the throttle exchanges with the secondary refrigerant in the evaporator, absorbs heat, and becomes saturated or superheated vapor to be compressed by the compressor.
Correo electrónico: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Enfriadoras de recirculación / Criotermostatos
El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.
Temperatura | Serie -25°C ~ +30°C | Serie -45°C ~ +30°C | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C | ||||
Capacidad de refrigeración | 0,8 ~ 30 kW | 0,75 ~ 12 kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Enfriadoras de agua / Enfriadoras pequeñas
El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.
Temperatura | -18°C ~ +30°C | Serie +5°C ~ +35°C | |||||||
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1,8 ~ 50 kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Refrigeradores de baja temperatura
Estamos especializados en la producción de refrigeradores de baja temperatura con un rango de control de temperatura de hasta -150°C, que pueden satisfacer las necesidades de refrigeración de diferentes industrias.
Temperatura | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C | Serie -150°C ~ -110°C | |||
Capacidad de refrigeración | 12 ~ 360 kW | 6 ~ 180 kW | 6 ~ 180 kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11 kW | |||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Enfriadoras y calefactoras
Rango de control de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | ||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Enfriadoras de recirculación
Rango de control de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |