Jacketed Glass Reactor Heating and Cooling Systems
Dynamic temperature control of jacketed glass reactors is a key step in the chemical reaction process, which directly affects the reaction rate, product quality and energy efficiency. Dynamic temperature control usually requires a precise and responsive control system to adjust in time according to the temperature changes during the reaction process to maintain the required reaction conditions. Here are a few key points:
Temperature Control Unit (TCU):
The TCU should have high-precision temperature control capabilities and be able to respond quickly to temperature changes to adapt to temperature fluctuations that may occur during the reaction process. Dynamic response speed is an important consideration in selecting a TCU because temperature changes during the reaction process can be very rapid.
Medium Circulation System:
The temperature inside the reactor is controlled by circulating a heating or cooling medium (such as water, oil or salt bath) in the jacket. • The temperature, flow rate and pressure of the circulating medium need to be precisely controlled to ensure the stability and accuracy of temperature control.
Sensors and Monitoring:
Temperature sensors are placed inside the reactor and in the jacket to monitor temperature changes in real time.
The data acquisition system is used to collect temperature data and feed it back to the control system for real-time adjustments.
Control strategy:
PID (proportional-integral-derivative) controller is a commonly used control algorithm that adjusts the control signal according to the deviation between the set point and the actual measurement value.
More advanced control strategies, such as fuzzy logic control or model predictive control, can also be used for more complex reaction process control.
Safety measures:
Over-temperature protection and emergency shutdown mechanisms are designed to prevent safety accidents caused by temperature runaway.
Operation interface:
User-friendly operation interface allows operators to set parameters, monitor status and adjust control strategies.
Maintenance and calibration: Regularly check and calibrate temperature sensors and control systems to ensure long-term accuracy and reliability.
The above factors should be fully considered when selecting and designing the dynamic temperature control system of the jacketed glass reactor to meet the temperature control needs of specific chemical reactions. In addition, with the advancement of technology, some new control systems and methods are also developing, such as more intelligent and automated systems, which can further improve control accuracy and efficiency.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
Ofrecemos soluciones personalizadas no estándar. Disponemos tanto de enfriadoras individuales como de unidades combinadas de refrigeración y calefacción.
Correo electrónico: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Sistemas de refrigeración y calefacción (serie SUNDI)
- Rango de temperatura: -120℃ ~ +350℃
- Control inteligente de la temperatura de alta precisión
- Capacidad de refrigeración: 0,5 kW ~ 1200 kW
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | ||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Circuladores de refrigeración y calefacción
- Rango de temperatura: -45℃ ~ +250℃
- Compresor Emerson Copeland, calidad fiable
- Función de autodiagnóstico, múltiples dispositivos de protección de seguridad
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Sistemas de refrigeración y calefacción (serie WTD)
- (Microcanales / reactores tubulares especializados)
- Rango de temperatura: -70℃ ~ +300℃
- Bomba de circulación de alto rendimiento, efecto de control de temperatura más estable
- Amplia gama de temperaturas para satisfacer las necesidades de más industrias
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW | ||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
TCU Sistema de control de temperatura multirreactores
- Rango de temperatura: -120℃ ~ +250℃
- Control de temperatura hermético y repetible
- Sistema auxiliar de aceite térmico de calefacción eléctrica incorporado
- Añade módulos de intercambio de calor por fuente de frío y calor en función de las necesidades
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C | |||||
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW | |||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Rango de temperatura: -150℃ ~ -5℃
- Compresor de marca internacional, alta eficiencia de refrigeración
- Tecnología de subenfriamiento secundario, velocidad de enfriamiento rápida
- Control y funcionamiento automatizados, eficientes y ahorradores de energía
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Six product series
Temperatura | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Capacidad de refrigeración | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Rango de temperatura: -120℃ ~ +30℃
- Compresor de marca internacional, tecnología de refrigeración en cascada
- Utilice etilenglicol o una mezcla de etilenglicol y agua
- Diseño totalmente sellado para garantizar la pureza del medio
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Capacidad de refrigeración | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Small Chillers / Mini Chillers
- Rango de temperatura: -18℃ ~ +35℃
- Compresor de marca internacional, rendimiento estable
- Controlador de microordenador, unidad de ajuste 0.1℃
- Ahorro de energía, alta precisión de control de la temperatura
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Two product series
Temperatura | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1.8kW…50kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Refrigeradores de alta temperatura
- Rango de temperatura: -100℃ ~ +80℃
- Compresores y otros accesorios de marcas internacionales
- Diseño totalmente sellado para garantizar la pureza del medio
- Controlador programable PLC
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Capacidad de refrigeración | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |