Jacketed Reactor Temperature Control Device
The temperature control device of the jacketed reactor is a key device to ensure that the chemical reaction is carried out under precise temperature conditions. It usually includes the following key parts:
1. Cold and heat sources: Depending on the process requirements, the cold and heat sources can be hot water, steam, thermal oil or refrigerant. Steam or thermal oil is used as the heating medium at high temperatures, and cold water or refrigerant is used for cooling at low temperatures.
2. Temperature Control Unit (TCU): This usually refers to a dynamic control unit, which is responsible for adjusting the temperature and flow rate of the hot fluid flowing into or out of the jacket to achieve the required reaction temperature. The TCU needs to have the characteristics of high control accuracy, fast dynamic response speed, temperature uniformity and ease of operation, and it also needs to have multiple safety protection functions such as overheating and overcurrent.
3. Sensors and controllers: Temperature sensors (such as thermocouples or RTDs) are installed inside the reactor or in the jacket to monitor temperature changes in real time and feed back data to the controller (such as PLC or PID controller). The controller automatically adjusts the heating or cooling action of the TCU according to the preset temperature curve or actual reaction requirements.
4. Refrigeration and heating system: This is a device that integrates heating and cooling functions in one, which can quickly increase and decrease the temperature and is suitable for reaction processes that require frequent temperature changes. The integrated cooling and heating machines provided by Wuxi Guanya Refrigeration are examples of such equipment. They can effectively deal with the difficulties of reactor jacket temperature control and ensure constant temperature control.
5. Pipes and accessories: Includes Teflon tubes or bellows for conveying hot fluids, and high-temperature resistant connection accessories. The cooling water outlet needs to be equipped with a hose or cotton yarn tube made of high-temperature resistant materials to ensure the safety and efficiency of the entire system.
6. Installation and layout: During installation, attention should be paid to circuit connection, equipment layout, and the design and construction of the cooling water system to ensure that all components meet safety regulations and efficient operation requirements. When selecting and installing the jacket reactor temperature control device, it is necessary to comprehensively consider the specific requirements of the reaction process, the performance parameters of the equipment, the convenience of operation and safety factors to ensure that the reaction process is both efficient and safe.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
Ofrecemos soluciones personalizadas no estándar. Disponemos tanto de enfriadoras individuales como de unidades combinadas de refrigeración y calefacción.
Correo electrónico: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Sistemas de refrigeración y calefacción (serie SUNDI)
- Rango de temperatura: -120℃ ~ +350℃
- Control inteligente de la temperatura de alta precisión
- Capacidad de refrigeración: 0,5 kW ~ 1200 kW
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | ||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Circuladores de refrigeración y calefacción
- Rango de temperatura: -45℃ ~ +250℃
- Compresor Emerson Copeland, calidad fiable
- Función de autodiagnóstico, múltiples dispositivos de protección de seguridad
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Sistemas de refrigeración y calefacción (serie WTD)
- (Microcanales / reactores tubulares especializados)
- Rango de temperatura: -70℃ ~ +300℃
- Bomba de circulación de alto rendimiento, efecto de control de temperatura más estable
- Amplia gama de temperaturas para satisfacer las necesidades de más industrias
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW | ||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
TCU Sistema de control de temperatura multirreactores
- Rango de temperatura: -120℃ ~ +250℃
- Control de temperatura hermético y repetible
- Sistema auxiliar de aceite térmico de calefacción eléctrica incorporado
- Añade módulos de intercambio de calor por fuente de frío y calor en función de las necesidades
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C | |||||
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW | |||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Rango de temperatura: -150℃ ~ -5℃
- Compresor de marca internacional, alta eficiencia de refrigeración
- Tecnología de subenfriamiento secundario, velocidad de enfriamiento rápida
- Control y funcionamiento automatizados, eficientes y ahorradores de energía
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Six product series
Temperatura | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Capacidad de refrigeración | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Rango de temperatura: -120℃ ~ +30℃
- Compresor de marca internacional, tecnología de refrigeración en cascada
- Utilice etilenglicol o una mezcla de etilenglicol y agua
- Diseño totalmente sellado para garantizar la pureza del medio
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Capacidad de refrigeración | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Small Chillers / Mini Chillers
- Rango de temperatura: -18℃ ~ +35℃
- Compresor de marca internacional, rendimiento estable
- Controlador de microordenador, unidad de ajuste 0.1℃
- Ahorro de energía, alta precisión de control de la temperatura
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Two product series
Temperatura | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1.8kW…50kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Refrigeradores de alta temperatura
- Rango de temperatura: -100℃ ~ +80℃
- Compresores y otros accesorios de marcas internacionales
- Diseño totalmente sellado para garantizar la pureza del medio
- Controlador programable PLC
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Capacidad de refrigeración | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |