Laboratory Heater/Chiller for Jacketed Reactor
The cooling and heating units of the jacketed reactor are key components of its temperature control. They ensure that the materials in the reactor react effectively within a specific temperature range. The working principles of these two units are as follows:
Heating unit
1. Steam heating: A common method is to heat the jacket by filling it with steam. This usually requires an external steam boiler as a steam source. The steam circulates in the jacket and transfers heat to the materials in the reactor. The heating efficiency is high, but the initial hardware investment is large.
2. Electric heating: In some small or low-speed applications, the reactor may be equipped with electric heating elements, which are directly embedded in the jacket or fixed to the outside of the reactor. Electric heating has a fast response and is easy to control, but the operating cost is relatively high.
3. Heat transfer oil circulation: Heating is achieved by circulating heat transfer oil through the coils in the jacket. Heat transfer oil has good thermal stability and can effectively transfer heat over a wide temperature range. This method is flexible to control and heats evenly.
Refrigeration unit
1. Cold water circulation: The refrigeration unit usually uses cold water or refrigerant to circulate in the jacket to absorb the heat inside the reactor to achieve a cooling effect. Cold water can be supplied by an external refrigerator or chiller, and the temperature is adjustable.
2. Refrigerant circulation: Similar to thermal oil circulation heating, but using low-temperature refrigerants, such as Freon or other environmentally friendly refrigerants, to circulate in the coil to extract heat and achieve rapid cooling.
3. All-in-one cooling and heating machine: Some high-end jacketed reactors are equipped with all-in-one cooling and heating machines, which can quickly switch between heating and cooling. Through advanced control systems, the temperature in the reactor can be accurately controlled to meet the complex requirements of temperature changes during the reaction process.
Temperature control system
Whether heating or cooling, jacketed reactors are usually equipped with temperature sensors and automatic control systems (such as PID controllers) to monitor the temperature in the reactor in real time and automatically adjust the working status of the heating or cooling unit to maintain the set temperature point to ensure the stability and repeatability of the reaction conditions. The selection of the control unit needs to consider factors such as control accuracy, response speed and ease of operation to meet different experimental or production requirements.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
Ofrecemos soluciones personalizadas no estándar. Disponemos tanto de enfriadoras individuales como de unidades combinadas de refrigeración y calefacción.
Correo electrónico: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Sistemas de refrigeración y calefacción (serie SUNDI)
- Rango de temperatura: -120℃ ~ +350℃
- Control inteligente de la temperatura de alta precisión
- Capacidad de refrigeración: 0,5 kW ~ 1200 kW
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | ||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Circuladores de refrigeración y calefacción
- Rango de temperatura: -45℃ ~ +250℃
- Compresor Emerson Copeland, calidad fiable
- Función de autodiagnóstico, múltiples dispositivos de protección de seguridad
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Sistemas de refrigeración y calefacción (serie WTD)
- (Microcanales / reactores tubulares especializados)
- Rango de temperatura: -70℃ ~ +300℃
- Bomba de circulación de alto rendimiento, efecto de control de temperatura más estable
- Amplia gama de temperaturas para satisfacer las necesidades de más industrias
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW | ||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
TCU Sistema de control de temperatura multirreactores
- Rango de temperatura: -120℃ ~ +250℃
- Control de temperatura hermético y repetible
- Sistema auxiliar de aceite térmico de calefacción eléctrica incorporado
- Añade módulos de intercambio de calor por fuente de frío y calor en función de las necesidades
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C | |||||
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW | |||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Rango de temperatura: -150℃ ~ -5℃
- Compresor de marca internacional, alta eficiencia de refrigeración
- Tecnología de subenfriamiento secundario, velocidad de enfriamiento rápida
- Control y funcionamiento automatizados, eficientes y ahorradores de energía
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Six product series
Temperatura | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Capacidad de refrigeración | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Rango de temperatura: -120℃ ~ +30℃
- Compresor de marca internacional, tecnología de refrigeración en cascada
- Utilice etilenglicol o una mezcla de etilenglicol y agua
- Diseño totalmente sellado para garantizar la pureza del medio
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Capacidad de refrigeración | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Small Chillers / Mini Chillers
- Rango de temperatura: -18℃ ~ +35℃
- Compresor de marca internacional, rendimiento estable
- Controlador de microordenador, unidad de ajuste 0.1℃
- Ahorro de energía, alta precisión de control de la temperatura
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Two product series
Temperatura | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1.8kW…50kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Refrigeradores de alta temperatura
- Rango de temperatura: -100℃ ~ +80℃
- Compresores y otros accesorios de marcas internacionales
- Diseño totalmente sellado para garantizar la pureza del medio
- Controlador programable PLC
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Capacidad de refrigeración | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |