Laboratory Reactor Temperature Control System
The temperature control system of a laboratory reactor is an important part of ensuring that experiments proceed smoothly under precise temperature conditions. It has many features and technical solutions. Here are a few key points:
1. Closed circulation system: Some advanced laboratory reactor temperature control systems are designed as fully closed liquid circulation systems, which means that there are no valves in the entire cycle, thereby reducing the risk of leakage and maintenance requirements. The system is usually equipped with an expansion vessel, which is insulated from the liquid circulation and is only mechanically connected to accommodate changes in the volume of the medium without directly participating in heat exchange, ensuring that the temperature of the medium in the expansion vessel can be maintained at a safe level, such as below 60°C, even at extreme temperatures.
2. Wide temperature range control: Advanced temperature control systems can achieve a wide temperature control range from -100 to 200°C on a single device, and can provide cooling capacity from -1KW to 80KW to meet the stringent temperature control requirements of different experiments.
3. Integrated heating and cooling: The reactor coil cooling and heating temperature control system integrates cooling and heating functions, and accurately controls the temperature of the materials inside the reactor through the refrigerant or heat medium flowing through the special coil. This design not only improves the flexibility of temperature control, but also enables fast and precise temperature rise and fall.
4. Diversified temperature control methods: In addition to the above-mentioned coil control temperature control system, there are also water bath temperature control, oil bath temperature control, internal circulation temperature control and external circulation temperature control. These methods control the temperature of the reactor through different heat exchange media and mechanisms, each with its own advantages, such as the simplicity and practicality of water baths, the high thermal conductivity and heat capacity of oil baths, and the improvement of temperature control accuracy by internal and external circulation.
5. Intelligent control: Modern laboratory reactors are usually equipped with advanced control systems, such as digital display instruments, which can realize automatic temperature management by setting parameters such as upper and lower temperature alarms and working temperatures. The controller can automatically adjust the heating or cooling power according to the temperature information fed back by the sensor to ensure the stability of the reaction conditions.
6. Safety and maintenance: The temperature control system also focuses on safety design, such as preventing thermal shock, ensuring smooth temperature changes during cooling, and avoiding equipment damage. At the same time, the system is easy to maintain, such as easy-to-replace heating elements and easy-to-clean structural designs. In summary, the temperature control system of the laboratory reactor is a highly specialized and sophisticated device designed to meet the high standards of temperature control required for scientific research. Choosing the right temperature control system is crucial to the success of the experiment.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
Ofrecemos soluciones personalizadas no estándar. Disponemos tanto de enfriadoras individuales como de unidades combinadas de refrigeración y calefacción.
Correo electrónico: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Sistemas de refrigeración y calefacción (serie SUNDI)
- Rango de temperatura: -120℃ ~ +350℃
- Control inteligente de la temperatura de alta precisión
- Capacidad de refrigeración: 0,5 kW ~ 1200 kW
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | ||
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | ||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Circuladores de refrigeración y calefacción
- Rango de temperatura: -45℃ ~ +250℃
- Compresor Emerson Copeland, calidad fiable
- Función de autodiagnóstico, múltiples dispositivos de protección de seguridad
- Sistema totalmente cerrado para prolongar la vida útil del fluido térmico
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C | |||||||
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Sistemas de refrigeración y calefacción (serie WTD)
- (Microcanales / reactores tubulares especializados)
- Rango de temperatura: -70℃ ~ +300℃
- Bomba de circulación de alto rendimiento, efecto de control de temperatura más estable
- Amplia gama de temperaturas para satisfacer las necesidades de más industrias
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW | ||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
TCU Sistema de control de temperatura multirreactores
- Rango de temperatura: -120℃ ~ +250℃
- Control de temperatura hermético y repetible
- Sistema auxiliar de aceite térmico de calefacción eléctrica incorporado
- Añade módulos de intercambio de calor por fuente de frío y calor en función de las necesidades
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C | |||||
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW | |||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Rango de temperatura: -150℃ ~ -5℃
- Compresor de marca internacional, alta eficiencia de refrigeración
- Tecnología de subenfriamiento secundario, velocidad de enfriamiento rápida
- Control y funcionamiento automatizados, eficientes y ahorradores de energía
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Six product series
Temperatura | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Capacidad de refrigeración | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Rango de temperatura: -120℃ ~ +30℃
- Compresor de marca internacional, tecnología de refrigeración en cascada
- Utilice etilenglicol o una mezcla de etilenglicol y agua
- Diseño totalmente sellado para garantizar la pureza del medio
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Capacidad de refrigeración | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Small Chillers / Mini Chillers
- Rango de temperatura: -18℃ ~ +35℃
- Compresor de marca internacional, rendimiento estable
- Controlador de microordenador, unidad de ajuste 0.1℃
- Ahorro de energía, alta precisión de control de la temperatura
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Two product series
Temperatura | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1.8kW…50kW | |||||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |
Refrigeradores de alta temperatura
- Rango de temperatura: -100℃ ~ +80℃
- Compresores y otros accesorios de marcas internacionales
- Diseño totalmente sellado para garantizar la pureza del medio
- Controlador programable PLC
- Cada dispositivo se somete a pruebas de carga durante más de 12 horas
Five product series
Temperatura | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Capacidad de refrigeración | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración. |