Buscar en Buscar todos

Process Chilled Water Systems

ClasificaciónNoticias del sector 304 0

Process Chilled Water Systems

Póngase en contacto con nosotros hoy mismo para obtener la solución de control de temperatura perfecta

 

Process Chilled Water Systems are indirect cooling devices used for key equipment in semiconductor, microelectronics and other industries. Divided into open system and closed system.

Process Chilled Water Systems have a wide range of applications, involving all aspects of industrial production, including semiconductors, microelectronics, industrial refrigeration machines, steam turbine exhaust condensation in thermal power plants, large central air conditioners, coal chemical industry, petrochemical plants, and natural gas pipeline cooling A large amount of process cooling water is used in such places. In many product or process production environments, clean workshops are required. The temperature and relative humidity in the workshop are required to be maintained within a certain range throughout the year. Some of the production processes generate large amounts of heat, and process equipment requires low-temperature water cooling. Even in winter, air conditioning is still required for cooling. , in order to meet these requirements, Process Chilled Water Systems must be built.

 

Process Chilled Water Systems

 

The composition and working principle of Process Chilled Water Systems

Process Chilled Water Systems mainly include the following parts: chillers, pumps, heat exchangers, water tanks, filters, and process equipment.

Chiller: Provides cold source for cooling water system.

Water pump: pressurizes water to ensure its circulation in the cooling system.

Heat exchanger: This equipment is used to exchange heat between the chilled water system and the cooling water system to transfer the heat generated at the load end of the system to the chilled water system. There are many types of heat exchangers, which can be divided into shell-and-tube type, plate type, plate-fin type, heat pipe type, etc. In comparison, plate heat exchangers have the advantages of small floor space and large heat transfer area. Considering the space and cost characteristics of semiconductor factories, equipment with small floor space is preferred to save land area and project cost.

Water tank: The water tank in the open system mainly serves to supplement the water source. The water tank in a closed system needs to choose an expansion water tank. The expansion water tank has three functions. One is to contain and compensate for the expansion and contraction of water in the system; the other is to provide stable pressure to the closed circulating water system and stabilize the system pressure; The third is as an instruction for the system water replenishment pump, usually the expansion tank sends a signal to start or shut down the system water replenishment pump.

Filter: Filter out solid impurities in the water and purify the water source.

Process Chilled Water Systems has two relatively independent systems: chilled water and cooling water. Chilled water is provided by a chiller. Chilled water exchanges heat with cooling water to cool the cooling water and thereby reduce the temperature of the equipment. Water is pumped from the production equipment through the water pump to the heat exchanger to ensure the temperature of the process cooling water by controlling the amount of chilled water. After passing through the filter, it is sent to the production line equipment and then returns to the water pump. The process cooling water is circulated repeatedly. Chilled water is returned directly to the chiller.

 

Process Chilled Water Systems

 

Process Chilled Water Systems Mode Selection

The mode of process cooling water system is divided into open system and closed system. How to choose open system and closed system during the design process should be based on the following situations:

① When the height difference between the highest point of the process equipment and the water pump plate replacement equipment is relatively large (height difference exceeds 10m), it is recommended to use a closed system, so that the residual pressure and static head of the equipment can be fully utilized;

② When the water supply pressure of process equipment is very high but the pressure difference of the equipment is not large, it is recommended to use a closed system, so that the residual pressure of the pipe network can be used to reduce the water pump head and save energy;

③When the plant process equipment is put into production in phases or in batches or when the equipment update and adjustment are relatively simple, considering the system debugging ability, it is recommended to use an open system, which can speed up the system debugging and operation. At the same time, due to the addition of a water tank, the system retains more water and the cold source When interrupted, it has certain accident buffering capabilities.

④ From the perspective of energy saving, the use of a closed system can greatly reduce the head of the process cooling water supply circulation pump. On the one hand, it can save the initial investment, on the other hand, it can save energy and reduce operating costs.

⑤ When the cooling water temperature of the equipment can be directly cooled by a cooling tower on the hottest days or the owner requires low investment, an open system can be used. When the equipment cooling water inlet temperature cannot be met by an open cooling tower, a closed system is used, using chilled water as the refrigerant.

 


 

Ofrecemos diseño y fabricación de sistemas completos de control de temperatura. Desde modelos estándar hasta productos personalizados completos de hasta 900 toneladas. Nos especializamos en el servicio al cliente y nos dedicamos a ayudar a cada cliente a tener el sistema de control de temperatura óptimo para su necesidad específica.

Ofrecemos soluciones personalizadas no estándar. Disponemos tanto de enfriadoras individuales como de unidades combinadas de refrigeración y calefacción.

solicitar

Correo electrónico: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Enfriadoras                                                                                                     

 

enfriador de recirculación

Enfriadoras de recirculación / Criotermostatos

(Diseños a medida)

El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.

 

 

Temperatura Serie -25°C ~ +30°C Serie -45°C ~ +30°C Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Capacidad de refrigeración0,8 ~ 30 kW0,75 ~ 12 kW0,4 ~ 6kW0,2 ~ 6kW0,3 ~ 5kW
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración.

 


 

Enfriadoras de precisión / Enfriadoras pequeñasEnfriadoras de agua / Enfriadoras pequeñas

(Diseños a medida)

El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.

 

 

Temperatura -18°C ~ +30°C Serie +5°C ~ +35°C
Capacidad de refrigeración0,35 ~ 0,9 kW1,8 ~ 50 kW
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración.

 


 

refrigerador de baja temperatura

Refrigeradores de baja temperatura

(Diseños a medida)

Estamos especializados en la producción de refrigeradores de baja temperatura con un rango de control de temperatura de hasta -150°C, que pueden satisfacer las necesidades de refrigeración de diferentes industrias.

 

 

Temperatura Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°CSerie -110°C ~ -50°C Serie -150°C ~ -110°C
Capacidad de refrigeración12 ~ 360 kW6 ~ 180 kW6 ~ 180 kW4 ~ 180kW2 ~ 120kW2,5 ~ 11 kW
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración.

 


ENFRIADOR DE SEMICONDUCTORES

 

Refrigeradores de alta temperatura

(Diseños a medida)

El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.

 

 

Temperatura +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Capacidad de refrigeración6 ~ 40kW2 ~ 15kW1 ~ 8kW0,6 ~ 3 kW1,5 ~ 3 kW
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración.

 

 

Enfriadoras y calefactoras                                                                            

 

Enfriadoras y calefactoras

(Diseños a medida)

Rango de control de temperatura: -120°C a +350°C

termostato de refrigeración y calefacción, ampliamente utilizado en diversas industrias.

 

Temperatura Serie -10 ~ +150°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C
Capacidad de refrigeración1,5 ~ 15 kW1 ~ 200 kW1 ~ 200 kW0,45 ~ 200 kW0,9 ~ 25 kW0,25 ~ 60 kW0,75 ~ 25 kW0,4 ~ 15 kW0,3 ~ 80 kW0,2 ~ 80 kW0,45 ~ 80 kW
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración.

 


 

Enfriadoras de recirculación

(Diseños a medida)

Rango de control de temperatura: -45°C a +250°C

 

Temperatura Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Capacidad de refrigeración1 ~ 15 kW0,25 ~ 15 kW
Nota: Se puede personalizar cualquier rango de temperatura de -150℃ ~ +350℃ y cualquier capacidad de refrigeración.

La información sobre derechos de autor pertenece a lneya-online.com, por favor contacte por correo electrónico para más detalles: lilia@lneya.com

O escanee el código QR de WhatsApp o WeChat que aparece a continuación para ponerse en contacto con nosotros. 

WhatsAPP WeChat

escanear

Anterior: Siguiente:
Últimas noticias
Solicitar presupuesto
Nombre
Dirección de correo electrónico
Teléfono
Empresa
Mensaje

购物车

X

我的足迹

X
palabras clave:Alegría embotellada enfriador de agua