Small Recirculating Water Chiller
It is important to have a high-quality small recirculating water chiller, but using proper skills in the process of using the chiller may make your work more effective. We have sorted out the user’s skills in the process of using small recirculating water chiller for you, hoping to provide some valuable suggestions.
After purchasing a small recirculating water chiller, pay attention to the installation of the equipment, which will greatly improve the performance of the industrial chiller. First check whether the machine is in good condition, whether the installation site is empty, and whether the location is suitable. A suitable and sufficient space should be selected to facilitate the normal operation and future maintenance of the small recirculating water chiller. Hard cement ground is recommended for installation, plus installation pads. The installed ground cement is about 50mm thick and can bear the operating weight of the equipment.
Small recirculating water chiller should be installed at a room temperature between 5°C and 35°C. There is no shelter around and above the equipment, and enough space should be left for smooth ventilation and normal operation of the equipment. The pipe installation space should also be sufficient, and the connecting part of the pipe can use door openings or other openings in suitable positions. The water in the room should be unobstructed. Appropriate pipe diameters should be selected for water pipes to ensure the flow and pressure of the cooling system and cold water system when the small recirculating water chiller is running at maximum power, and to ensure the correct connection between pipe fittings.
The reasonable utilization efficiency of small recirculating water chiller is the main method to improve utilization efficiency. When using the product, the cooling water capacity should be reasonably selected, or the operating speed should be adjusted. The load experiment shows that under the condition of ensuring the safe operation of the refrigeration equipment, when the equipment operates at a load of 70%-80%, the power consumption per unit cooling capacity is the smallest.
Reducing the condensation temperature of small recirculating water chiller is an important way to improve refrigeration efficiency. Under the premise of meeting the operation, installation and refrigeration requirements, try to increase the evaporation temperature and reduce the condensation temperature. For example, when installing a water-cooled small recirculating water chiller, there must be a certain margin when selecting a matching industrial cooling tower. At the same time, comprehensively consider the operation of pipeline water pumps and cooling towers, and increase the transformation of the original cooling tower circulating water system to ensure the cooling efficiency of cooling water.
Avoiding and reducing the scaling of pipes in the small recirculating water chiller can improve the heat exchange efficiency of the condenser and evaporator. When the equipment is running for a long time, if the cooling water and chilled water in the system are not properly disposed of, calcium bicarbonate and magnesium bicarbonate in the circulating water will produce calcium carbonate and magnesium carbonate, which will accumulate on the pipe wall of the pipe or heat exchanger. Decrease the thermal conductivity, affect the heat exchange efficiency of the condenser and evaporator, and increase the power consumption of the equipment. Therefore, when we use the small recirculating water chiller, we should use the corresponding technology to treat the water, and regularly descale and clean the water system pipes and cooling towers to improve the heat exchange efficiency.
Refrigeradores de baja temperatura (Diseños a medida)
Estamos especializados en la producción de refrigeradores de baja temperatura con un rango de control de temperatura de hasta -150°C, que pueden satisfacer las necesidades de refrigeración de diferentes industrias.
Temperatura | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C | Serie -150°C ~ -110°C |
Capacidad de refrigeración | 12 ~ 360 kW | 6 ~ 180 kW | 6 ~ 180 kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11 kW |
Enfriadoras de recirculación (Diseños a medida)
Nuestro enfriador de recirculación adopta tecnología de refrigeración de baja temperatura, la temperatura es tan baja como -120℃, y varios accesorios son personalizables.
Temperatura | Serie -25°C ~ +30°C | Serie -45°C ~ +30°C | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Capacidad de refrigeración | 0,8 ~ 30 kW | 0,75 ~ 12 kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW |
Refrigeradores de temperatura ambiente / Refrigeradores pequeños (Diseños a medida)
El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.
Temperatura | -18°C ~ +30°C | Serie +5°C ~ +35°C |
Capacidad de refrigeración | 0,35 ~ 0,9 kW | 1,8 ~ 50 kW |
Chillers for Automotive Battery Test (Diseños a medida)
Simulación de temperatura para pruebas de calidad de vehículos: prueba de duración de baterías, banco de pruebas de inyectores/motores de combustible, prueba de airbags, banco de pruebas de componentes, etc.
Temperatura | -25°C ~ +100°C | -40°C ~ +100°C | 0°C ~ +100°C | -40°C ~ +135°C |
Capacidad de refrigeración | 2,8 ~ 38 kW | 1,2 ~ 60 kW | 1,8 ~ 60 kW | 4 ~ 60kW |
La temperatura, la presión y el caudal pueden controlarse de forma independiente.
1&2: una máquina para el control de dos grupos.
Temperatura | -40 ~ +100℃ 1&2 | 0 ~ +100℃ 1&2 |
Capacidad de refrigeración | 1,8 kW*2 ~ 60 kW*2 | 1,8 kW*2 ~ 60 kW*2 |
La temperatura permanece constante, la presión y el caudal pueden controlarse independientemente.
1&3: una máquina para el control de tres grupos.
1&6: una máquina para el control de seis grupos.
Temperatura | -40 ~ +100℃ 1&2 | -40 ~ +100℃ 1&3 | -40 ~ +100℃ 1&6 | -20 ~ +100℃ 1&6 | 0 ~ +100℃ 1&2 | 0 ~ +100℃ 1&3 | 0 ~ +100℃ 1&6 |
Capacidad de refrigeración | 2,5 ~ 60 kW | 4 ~ 60kW | 10 ~ 60 kW | 10 ~ 60 kW | 7 ~ 60 kW | 11 ~ 60kW | 18 ~ 60 kW |
Semiconductor Enfriadoras (TES series) (Diseños a medida)
Adecuado para el control preciso de la temperatura de los componentes electrónicos. En la fabricación de componentes electrónicos semiconductores para entornos adversos, las fases de ensamblaje de embalajes de CI y de pruebas de ingeniería y producción incluyen pruebas térmicas electrónicas y otras simulaciones de pruebas ambientales.
Temperatura | Serie -45°C ~ +250°C | Serie -85°C ~ +200°C | Serie -60°C ~ +200°C |
Capacidad de refrigeración | 0,3 ~ 25 kW | 0,25 ~ 25 kW | 3 ~ 60kW |
Semiconductor Enfriadoras (LTS series) (Diseños a medida)
Adecuado para el control preciso de la temperatura de los componentes electrónicos. En la fabricación de componentes electrónicos semiconductores para entornos adversos, las fases de ensamblaje de embalajes de CI y de pruebas de ingeniería y producción incluyen pruebas térmicas electrónicas y otras simulaciones de pruebas ambientales.
Temperatura | Serie -20°C ~ +80°C | Serie -45°C ~ +80°C | Serie -60°C ~ +80°C | Serie -80°C ~ +80°C |
Control de caudal | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Enfriadoras para almacenamiento de energía(Diseños a medida)
Liquid Cooling Solutions For Battery Energy Storage Systems
Temperatura | -45°C ~ +55°C |
Capacidad de refrigeración | 45 kW |
Refrigeradores de tornillo (Diseños a medida)
Refrigeradores de tornillo de baja temperatura y refrigeradores de tornillo a temperatura ambiente
Temperatura | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacidad de refrigeración | 107 ~ 1027 kW (compresor único) | 299 ~ 2134 kW (compresor doble) | 98 ~ 934 kW (compresor único) | 272 ~ 1940 kW (compresor doble) | 48 ~ 467 kW (un compresor) | 51 ~ 497 kW (compresor único) |