Temperature Control in Bioreactor
The temperature control system in bioreactor is an instrument and equipment used in the chemical industry and pharmaceutical industry to connect reactors for dynamic temperature control of cooling and heating. So, in addition to temperature control in bioreactors, in what other ways can it be used?
Working principle of temperature control system in bioreactor
The working principle of the temperature control system in bioreactor is to drive the heat transfer medium (usually water, ethanol, silicone oil, etc.) from the oil tank equipped with a built-in heater to the temperature control device through a pump, and then from the temperature control device back to the oil tank. The controller adjusts the temperature of the hot fluid and thereby the temperature of the temperature control device based on the temperature of the hot fluid measured by the temperature sensor or the internal temperature of the temperature control device.
Typical applications of temperature control system in bioreactor:
Temperature control during the process;
Temperature control in small production processes;
Microchannel reactor temperature control;
Temperature control in reactor applications in chemical, pharmaceutical, and biotechnology fields;
Thermal test platform;
High and low temperature alternating material testing.
In the chemical industry, temperature control system in bioreactor is widely used. After the relevant users purchase the equipment, they need to carry out actual operation. However, many users do not know much about its main operations. If the operations are not performed as required, it will not only affect the performance and life of the equipment, but may even cause dangerous accidents. occur. This requires operators to have a basic understanding of the use of equipment when operating, so that they can operate the equipment better.
Correo electrónico: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Sistemas de refrigeración y calefacción (serie SUNDI)
Rango de control de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | -25 ~ +200°C una máquina para dos reactores | -40 ~ +200°C una máquina para dos reactores |
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | hasta 10*2 kW | hasta 10*2 kW |
Sistemas de refrigeración y calefacción (serie WTD)
(Microcanales / reactores tubulares especializados)
Rango de control de temperatura: de -70°C a +300°C
Diseño especializado para microcanal (pequeña capacidad de retención de líquido, gran capacidad de intercambio de calor, sistema de circulación de alta caída de presión)
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW |
Circuladores de refrigeración y calefacción
Rango de control de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C |
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW |
Termostatos de circulación
Rango de control de temperatura: +50°C a +300°C
Nota: La serie UC puede controlar la temperatura del medio de transferencia de calor. La serie UST no solo puede controlar la temperatura del medio de transferencia de calor, sino también la temperatura del material de reacción.
Temperatura | +50°C ~ +170°C (serie UC) | +50°C ~ +300°C (serie UC) | +50°C ~ +300°C (serie UST) |
Capacidad de calefacción | 5,5 ~ 15 kW | 3,5 ~ 130 kW | 3,5 ~ 95 kW |
TCU Sistema de control de temperatura multirreactores
Rango de control de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C |
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW |