Liquid Cooled Battery Racks
Contactez-nous dès aujourd'hui pour une solution parfaite de contrôle de la température
As the main energy storage component of electric vehicles, battery modules are key components of electric vehicles and directly affect the performance of electric vehicles. During the use of the battery module, due to the certain internal resistance of the internal cells, a certain amount of heat will be generated during normal operation, causing the internal temperature of the module to rise. The normal operating temperature range of the battery core is 15~35℃. Exceeding 60℃ will cause certain safety hazards. The generation and rapid accumulation of heat will inevitably increase the internal temperature of the battery, especially when used in high temperature environments or when charging and discharging with large currents. , may trigger a violent chemical reaction inside the battery, generating a large amount of heat. If the heat does not have time to dissipate and quickly accumulates inside the battery, the battery may leak, gas, smoke, etc. In severe cases, the battery may burn violently or even explode. In order to eliminate this danger, the battery module needs to be dissipated to prevent the battery core from being in a high temperature state for a long time, which will affect the performance of the battery core and reduce the service life of the battery core.
The working principle of the liquid cooling plate is that the excess heat generated by the battery operation is transferred through contact with the surface of the plate-shaped aluminum device. The liquid cooling system utilizes the characteristics of the large heat transfer coefficient of liquid flow and relies on the liquid flow to transfer high heat, and is eventually used. The cooling liquid passing through the internal flow channel of the device is carried away.
Battery modules have certain requirements for liquid cooling plates. The first is the high heat dissipation power, which can quickly take away the heat generated by the module and prevent the temperature from rising sharply; the second is high reliability. When the vehicle is walking on the road, the battery pack in working condition must undergo various environmental tests and vibrations. , impact, high and low temperature and other relatively harsh working environments, the working voltage of the power battery pack can easily reach several hundred volts, and the leakage of coolant will become a very serious problem. Even if a coolant with good insulation performance is used, it will encounter external substances. After being doped, its insulation performance will be immediately reduced, causing certain safety risks. Therefore, the reliability of the sealing of the liquid cooling plate is very important; in addition, the heat dissipation design must be precise to avoid excessive temperature differences within the system and the impact of the operating temperature on the battery. The performance and aging of the battery have a very important impact; the last is the weight requirement. The battery pack currently focuses on lightweighting, which requires every component in the pack to be lightweight. If the liquid cooling plate takes up too much weight, It will directly affect the energy density of the battery module, which is unacceptable.
In response to the above problems, liquid cooling plates generally use copper tubes buried in aluminum substrates during the design process. That is, the aluminum substrate is machined and milled with computer numerical control technology, and then a stamping machine is used to press the bent copper tubes onto the aluminum substrate. Perform brazing welding. This design, on the one hand, reduces the weight of aluminum and controls costs, and on the other hand, makes full use of the high thermal conductivity of copper tubes. Finally, two inlets and outlets are set up to inject the corresponding liquid refrigerant, usually water or a mixture of water and organic alcohol (alcohol can prevent water from freezing at low temperatures), and the water pump controls the circulation of the liquid. Water or a mixture of it and organic alcohol is used as a liquid cooling agent because in physics, the thermal conductivity coefficient and specific heat capacity of water are much larger than that of air, the heat conduction speed is fast, and the temperature rise is relatively slow, so water is a relatively Ideal heat dissipation medium. In the battery pack, because depending on the environment, water is easy to freeze when a low temperature environment occurs, which is very detrimental to heat dissipation. In order to solve this problem, a mixture ratio of water and organic alcohol is generally used as the refrigerant, and the results are very good. verification.
Liquid cooling refers to the cooling liquid that passes through the internal cooling pipes and cold plates of the battery pack to take away the heat generated by the battery during operation to reduce the temperature of the battery. The advantages are its high heat transfer coefficient, large thermal energy, fast cooling efficiency, and remarkable battery consistency. The disadvantage is that because the liquid exists inside, the safety performance is relatively high in a sealed space. Compared with air cooling and natural cooling, the cost is also relatively low.
Courriel : info@lneya.com ID WeChat : +8615251628237 WhatsApp : +86 17851209193
Refroidisseurs de précision / Petits refroidisseurs
Le refroidisseur peut être largement utilisé dans diverses industries et laboratoires, et peut être conçu sur mesure.
Plage de température | -18°C ~ +30°C | Série +5°C ~ +35°C |
Capacité de refroidissement | 0,35 ~ 0,9kW | 1,8 ~ 50kW |
Refroidisseurs à circulation
Notre refroidisseur à circulation adopte une technologie de réfrigération à basse température, la température est aussi basse que -120℃, et divers accessoires sont personnalisables.
Plage de température | Série -25°C ~ +30°C | Série -45°C ~ +30°C | Série -60°C ~ -20°C | Série -80°C ~ -20°C | Série -120°C ~ -70°C |
Capacité de refroidissement | 0,8 ~ 30kW | 0,75 ~ 12kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW |
Refroidisseurs à basse température
Nous sommes spécialisés dans la production de refroidisseurs à basse température avec une plage de contrôle de la température allant jusqu'à -150°C, qui peuvent répondre aux besoins de réfrigération de différentes industries.
Plage de température | Série -25°C ~ -5°C | Série -45°C ~ -10°C | Série -60°C ~ -10°C | Série -80°C ~ -30°C | Série -110°C ~ -50°C | Série -150°C ~ -110°C |
Capacité de refroidissement | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11kW |
Simulation de la température pour les tests de qualité des véhicules : test de durée de vie de la batterie, banc d'essai de l'injecteur de carburant/du moteur, test de l'airbag, banc d'essai des composants, etc.
Convient pour le contrôle précis de la température des composants électroniques. Lors de la fabrication de composants électroniques semi-conducteurs destinés à des environnements difficiles, les phases d'assemblage, d'ingénierie et d'essais de production de l'emballage des circuits intégrés comprennent des essais thermiques électroniques et d'autres simulations d'essais environnementaux.
Refroidissement par liquide pour les systèmes de stockage d'énergie par batterie
Les types | Pour la station de conversion | Pour les batteries de stockage d'énergie | Pour la station de recharge |
Capacité de refroidissement | 45kW | 5 ~ 8,5kW | 4kW |
Série ZLFQ
Unité de distribution du liquide de refroidissement
L'équipement de refroidissement liquide convient aux tests de semi-conducteurs, aux tests de température constante des équipements électroniques, au refroidissement de l'infrastructure de soutien des serveurs et à d'autres lieux de contrôle de la température des fluides.
Plage de température | +5°C ~ +35°C | +5°C ~ +35°C |
Capacité de refroidissement | 15 ~ 150kW | 200 ~ 500kW |
Série de mandrins thermiques MD
Il est utilisé pour tester les dispositifs RF et les dispositifs de puissance à haute densité (IGBT et MOSFET), et peut également être utilisé pour le refroidissement rapide des panneaux plats de laboratoire (plasma, produits biologiques, batteries), etc.
Plage de température | -75°C ~ +225°C |
Précision de la température | ±0.1℃ |
Refroidisseurs à vis (Modèles sur mesure)
Refroidisseurs à vis à basse température et refroidisseurs à vis à température ambiante
Plage de température | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacité de refroidissement | 107 ~ 1027kW (compresseur unique) | 299 ~ 2134kW (double compresseur) | 98 ~ 934kW (compresseur simple) | 272 ~ 1940kW (double compresseur) | 48 ~ 467kW (compresseur unique) | 51 ~ 497kW (compresseur simple) |