Search Search all

GX/GY -150°C ~ -20°C Cryogenic Freezers

GX/GY -150°C ~ -20°C Cryogenic Freezers

  • Temperature Control Range: -150°C ~ -20°C
  • French Tecumseh Compressor, German Bock Compressor, etc.
  • Non-Standard Sizes Can Be Customized

 

Contact us now to get the latest discount price!

Email: Lilia@lneya.com    WhatsApp: +86 17851209193

WhatsApp        /        WeChat
scan

 

 

 

 

Features of Industrial Freezers:

  • Microcomputer control, cascade temperature controller, digital temperature display, the regulation of unit 0.1°C, tank temperature range -150℃ ~ -10℃ adjustable.
  • French Tecumseh compressor, German Bock compressor, bitzer compressor, automatic cascade refrigeration technology.
  • With self-diagnosis function, freezer overload protection, high pressure switches, overload relays,thermal protection device and other security functions.
  • Three sealed mold layer of insulation, Extra-thick high-density polyurethane foam insulation layer,good insulation. Inside with vacuum insulation panels.
  • Large condenser design, fully guaranteed plant environment cooling effect.
  • Wide volume ratio design, large load capacity design.
  • Can set compressor temperature difference on and off.
  • Fault alarm (over-temperature alarm, sensor alarm, High pressure alarm, compressor over heat alarm. Delay boot protection, all components grounding safely.
  • LED display, display tank temperature and set temperature and can set the over temperature alarm and tank inside temperature, fault prompt functions.
    Non-standard sizes can be customized, Ultra-low temperature freezer(-100℃ tank within 100m3 volume).
  • Optional parts: PLC controller, color touch-screen, temperature recorder, etc.

Applications

lt is mainly used in industrial refrigerating treatment, so that the matrix of the metal structure to generate a uniform, fine and dispersed precipitation.The precipitation of carbide will improve the abrasion resistance, friction performance and increase hardness of metal.The carbide is the ideal alternative to liquid nitrogen.

Used for the copper sleeve and bearings contracting, it is widely used in precise mechanical assembly. Applied to large scale equipment lower temperature test.

Customer Cases

 

ModelGY-A228NGY-A250NGY-A2A10NGY-A350NGY-A3A10NGY-A550NGY-A5A10N
Volume280L500L1000L500L1000L500L1000L
Inner dimension800*600*6001200*650*6501550*800*7501200*650*6501550*800*7501200*650*6501550*800*750
Type(Vertical)
Capability carrying150KG220KG300KG220KG300KG220KG300KG
Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity when target artifact weight is greater than the standard capacity, the cooling rate will decrease)
Temp. range -120°C~-50°C Optional -120°C~20°C -135℃~-60℃ -150℃~-60℃
Cooling capacity0.7kW -110℃1 kW -110℃2 kW -110℃1kW -125℃2 kW -125℃1 kW -140℃2kW -140℃
Temp. accuracy±2℃±2℃±2℃±2℃±2℃±2℃±2℃
Heating power2kW3kW5kW3kW5kW3kW5kW
Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection.
Cooling rateAmbient temperature of 25℃, no-load,(from 0℃to -110℃ about 1 .5 hour;
from 0℃ to -140℃ about 2 hours, cooling rate will be a little different for ambient temperature changes.
ControllerASET multifunctional controller
Operation panel7-inch color touch screen, display set temperature, measured temperature.
Temp. recordTemperature curve and fault record, U-disk data export, excel format.
Inside circulating air2100 m³/h2750 m³/h4500 m³/h2750 m³/h4500 m³/h2750 m³/h4500 m³/h
When it is open, the internal circulation fan automatically turns off. The touch screen displays open state.
CompressorDorin
Intermediate heat exchangerKAORI Plate heat exchanger
Dry filterEmerson
Expansion valveElectronic expansion valve
EvaporatorCopper-tube with aluminum-fin
Cooling TypeAir-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30℃)
Means of insulationPolyurethane foam insulation, thermal insulation layer 150 mm, with embedded FIR boards
Safety ProtectionSelf-diagnosis function; Phase sequence phase failure protection; leakage protector; cooling unit overload protection;
high and low-pressure switch, overload relay, thermal protection, high-temperature protection and temperature
fault protection.
Case materialOutside is cold rolled steel painting, internal is SUS304 wire drawing board.
RefrigerantMix Refrigerant from LNEYA
Dimension
(mm)
2200*1150
*1150
3000*1200
*1200
3500*1300
*1300
2900*1200
*1200
3800*1600
*1400
3500*1600
*1400
4150*1800
*1450
Power 380V 50HZ12kW MAX16.5kW MAX20kW MAX18kW MAX25kW MAX23kW MAX40kW MAX
Weight570kg680kg850kg750kg900kg800kg1250kg
OptionalHigh temperature reaches 80℃ and temperature accuracy is ±0.5℃;the input power will be changed.
OptionalTemp. accuracy ±0.5℃
OptionalCooling and heating program controlled, meet cold treatment process requirements(can set 5 programs, each
program can edit 45 steps.)
OptionalInterior door, reduce cooling capacity lost when picking small workpieces (temperature below 60℃ optional)
OptionalOutside SUS304 wire drawing board case
OptionalDiameter 50mm cable hole
OptionalElectric heating vacuum glass observation window (with lighting) 200mm*300mm
OptionalLow temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at
low temperature for a long time even the door is open and close frequently)

ModelGY-A228NGY-A250NGY-A2A10NGY-A350NGY-A3A10NGY-A550NGY-A5A10N
Volume280L500L1000L500L1000L500L1000L
Inner dimension800*600*6001200*650*6501550*800*7501200*650*6501550*800*7501200*650*6501550*800*750
Type(Vertical)
Capability carrying150KG220KG300KG220KG300KG220KG300KG
Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity when target artifact weight is greater than the standard capacity, the cooling rate will decrease)
Temp. range -120°C~-50°C Optional -120°C~20°C -135℃~-60℃ -150℃~-60℃
Cooling capacity0.7kW -110℃1 kW -110℃2 kW -110℃1kW -125℃2 kW -125℃1 kW -140℃2kW -140℃
Temp. accuracy±2℃±2℃±2℃±2℃±2℃±2℃±2℃
Heating power2kW3kW5kW3kW5kW3kW5kW
Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection.
Cooling rateAmbient temperature of 25℃, no-load,(from 0℃to -110℃ about 1 .5 hour;
from 0℃ to -140℃ about 2 hours, cooling rate will be a little different for ambient temperature changes.
ControllerASET multifunctional controller
Operation panel7-inch color touch screen, display set temperature, measured temperature.
Temp. recordTemperature curve and fault record, U-disk data export, excel format.
Inside circulating air2100 m³/h2750 m³/h4500 m³/h2750 m³/h4500 m³/h2750 m³/h4500 m³/h
When it is open, the internal circulation fan automatically turns off. The touch screen displays open state.
CompressorDorin
Intermediate heat exchangerKAORI Plate heat exchanger
Dry filterEmerson
Expansion valveElectronic expansion valve
EvaporatorCopper-tube with aluminum-fin
Cooling TypeAir-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30℃)
Means of insulationPolyurethane foam insulation, thermal insulation layer 150 mm, with embedded FIR boards
Safety ProtectionSelf-diagnosis function; Phase sequence phase failure protection; leakage protector; cooling unit overload protection;
high and low-pressure switch, overload relay, thermal protection, high-temperature protection and temperature
fault protection.
Case materialOutside is cold rolled steel painting, internal is SUS304 wire drawing board.
RefrigerantMix Refrigerant from LNEYA
Dimension
(mm)
2200*1150
*1150
3000*1200
*1200
3500*1300
*1300
2900*1200
*1200
3800*1600
*1400
3500*1600
*1400
4150*1800
*1450
Power 380V 50HZ12kW MAX16.5kW MAX20kW MAX18kW MAX25kW MAX23kW MAX40kW MAX
Weight570kg680kg850kg750kg900kg800kg1250kg
OptionalHigh temperature reaches 80℃ and temperature accuracy is ±0.5℃;the input power will be changed.
OptionalTemp. accuracy ±0.5℃
OptionalCooling and heating program controlled, meet cold treatment process requirements(can set 5 programs, each
program can edit 45 steps.)
OptionalInterior door, reduce cooling capacity lost when picking small workpieces (temperature below 60℃ optional)
OptionalOutside SUS304 wire drawing board case
OptionalDiameter 50mm cable hole
OptionalElectric heating vacuum glass observation window (with lighting) 200mm*300mm
OptionalLow temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at
low temperature for a long time even the door is open and close frequently)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com